A Versatile Digital Readout System for the PANDA MVD

被引:0
|
作者
Mertens, Marius C. [1 ]
Huegging, Fabian [1 ]
Ritman, James [1 ]
Stockmanns, Tobias [1 ]
机构
[1] Forschungszentrum Julich, Julich, Germany
关键词
Detectors; Field programmable gate arrays; Data acquisition; Digital circuits; Reconfigurable architectures; MICRO-VERTEX-DETECTOR; FAIR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Micro Vertex Detector (MVD) for the PANDA experiment at the future Facility for Antiproton and Ion Research (FAIR) will be the innermost high precision vertexing detector, necessary for e.g. identification of displaced vertices of D-meson decays. Challenges include its triggerless; readout and a high occupancy due to its proximity to the interaction point. Thus, the MVD design foresees hybrid silicon pixel sensors for the inner layers, silicon strip sensors for the outer layers and a custom frontend chip which can sustain high data rates for the readout. During the development of the MVD, a flexible system is needed to test pixel and strip detector prototypes. Both the suitability of existing concepts and newly developed circuits have to be evaluated. In the following, a versatile digital readout system for device testing and evaluation on a tabletop scale is presented along with application examples from practical use. Its FPGA-based hardware, modular firmware and software are the key features which provide great flexibility and ease of use at the same time.
引用
收藏
页码:2705 / 2708
页数:4
相关论文
共 50 条
  • [41] Development of a digital signal readout system for large TES arrays
    Dreyer, J. G.
    Hennig, W.
    Tan, H.
    Niedermayr, T.
    Breus, D.
    Drury, O. B.
    Warburton, W. K.
    Friedrich, S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (3-4) : 958 - 963
  • [42] MPRS: Medipix parallel readout system for angiography digital imaging
    Fanti, V
    Marzeddu, R
    Randaccio, P
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 944 - 946
  • [43] AN AUTOMATIC DIGITAL READOUT SYSTEM FOR REACTION-RATE METHODS
    CORDOS, EM
    CROUCH, SR
    MALMSTADT, HV
    ANALYTICAL CHEMISTRY, 1968, 40 (12) : 1812 - +
  • [44] MPRS: Medipix parallel readout system for angiography digital imaging
    Fanti, V
    Marzeddu, R
    Randaccio, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1664 - 1666
  • [45] A digital readout system for the CMS Phase I Pixel Upgrade
    Stringer, R.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [46] INDIRECT BLOOD-PRESSURE MEASURING SYSTEM WITH DIGITAL READOUT
    EATON, JCR
    HENSON, TA
    BRITISH JOURNAL OF PHARMACOLOGY, 1975, 54 (02) : P282 - P282
  • [47] Development of a Digital Signal Readout System for Large TES Arrays
    J. G. Dreyer
    W. Hennig
    H. Tan
    T. Niedermayr
    D. Breus
    O. B. Drury
    W. K. Warburton
    S. Friedrich
    Journal of Low Temperature Physics, 2008, 151 : 958 - 963
  • [48] CHOOSING A DIGITAL READOUT
    RICHARDS, M
    MACHINERY, 1972, 78 (03): : 64 - &
  • [49] Readout of digital SiPMs
    Diehl, Inge
    Hansen, Karsten
    Kruger, Katja
    Reckleben, Christian
    Sefkow, Felix
    Yao, Yuan
    Andricek, Ladislav
    Ninkovic, Jelena
    Petrovics, Stefan
    Richter, Rainer
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [50] PDM. A versatile digital transmission system for video
    Burgess, G.D.
    International journal of digital and analog communication systems, 1992, 5 (03): : 145 - 155