Internal femoral component malrotation in TKA significantly alters tibiofemoral kinematics

被引:21
作者
Heyse, Thomas J. [1 ]
El-Zayat, Bilal F. [1 ]
De Corte, Ronny [2 ]
Chevalier, Yan [3 ]
Fuchs-Winkelmann, Susanne [1 ]
Labey, Luc [4 ]
机构
[1] Univ Hosp Marburg, Ctr Orthoped & Traumatol, D-35043 Marburg, Germany
[2] Smith & Nephew, Zaventem, Belgium
[3] Klinikum Grosshadern, Orthopad Klin & Poliklin, Lab Biomech & Expt Orthopadie, Munich, Germany
[4] Katholieke Univ Leuven, Mech Engn Technol TC, Geel, Belgium
关键词
Total knee arthroplasty; Component malrotation; Kinematics; Biomechanics; TOTAL KNEE ARTHROPLASTY; ROTATIONAL ALIGNMENT; PATELLAR TRACKING; IN-VITRO; GAIT; REPLACEMENT; PAIN;
D O I
10.1007/s00167-017-4778-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Femoral component malrotation in total knee arthroplasty (TKA) is clinically proven to cause dissatisfaction and impaired function. This study is an attempt to characterize the tibiofemoral kinematics following femoral malrotation in posterior stabilized (PS) TKA. It was hypothesized that internal malrotation would introduce the most pronounced changes. Six fresh-frozen cadaver specimens were mounted in a kinematic rig. Three motion patterns were applied with the native knee and following PS TKA (passive motion, open chain extension, and squatting) while infrared cameras recorded the trajectories of markers attached to femur and tibia. Three different femoral implants were tested: a conventional posterior stabilized component, and adapted components of the same implant with 5A degrees of intrinsic external and internal rotation, respectively. The implantation of the PS TKA resulted in less tibial internal rotation (squat 33-70A degrees, p < 0.05) and the medial femoral condyle shifted posteriorly especially in deep flexion (squat 84-111A degrees, p < 0.05). Internal component malrotation caused internal rotation and abduction of the tibia in flexion (squat 33-111A degrees, p < 0.05), an elevated (squat 43-111A degrees, p < 0.05) and more anterior (passive 61-126A degrees, p < 0.05) located medial femoral condyle and a lateral femoral condyle located more posterior and inferior (squat 73-111A degrees, p < 0.05) than in the neutrally aligned TKA. External component malrotation caused only little changes under passive motion. Under a squat there was less internal rotation and more adduction to the tibia (33-111A degrees, p < 0.05). The medial femoral condyle was moved more posterior (squat 59-97A degrees, p < 0.05), the lateral femoral condyle more superior (squat 54-105A degrees, p < 0.05) than in the neutrally aligned TKA. The greatest differences to the native tibiofemoral kinematics were introduced by internal rotation of the femoral component. Also neutrally and externally rotated femoral components introduce kinematic changes, but to a lesser extent. With respect to the alterations introduced to kinematics internal malrotation should be avoided when performing PS TKA.
引用
收藏
页码:1767 / 1775
页数:9
相关论文
共 31 条
  • [21] The effect of femoral component rotation on the kinematics of the tibiofemoral and patellofemoral joints after total knee arthroplasty
    Merican, A. M.
    Ghosh, K. M.
    Iranpour, F.
    Deehan, D. J.
    Amis, Andrew A.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) : 1479 - 1487
  • [22] MRI evaluation of rotational alignment and synovitis in patients with pain after total knee replacement
    Murakami, A. M.
    Hash, T. W.
    Hepinstall, M. S.
    Lyman, S.
    Nestor, B. J.
    Potter, H. G.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (09): : 1209 - 1215
  • [23] NAGAMINE R, 1994, CLIN ORTHOP RELAT R, P263
  • [24] Malrotation deformities of the lower extremity and implications on total knee arthroplasty: a narrative review
    Peersman, Geert
    Taeymans, Kim
    Jans, Christophe
    Vuylsteke, Philippe
    Fennema, Peter
    Heyse, Thomas
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (11) : 1491 - 1498
  • [25] The benefit of revision knee arthroplasty for component malrotation after primary total knee replacement
    Sternheim, Amir
    Lochab, Jasjit
    Drexler, Michael
    Kuzyk, Paul
    Safir, Oleg
    Gross, Allan
    Backstein, David
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (12) : 2473 - 2478
  • [26] Stukenborg-Colsman C, 2003, ORTHOPADE, V32, P319, DOI 10.1007/s00132-002-0442-6
  • [27] Biomechanical Effects of Total Knee Arthroplasty Component Malrotation: A Computational Simulation
    Thompson, Julie A.
    Hast, Michael W.
    Granger, Jeffrey F.
    Piazza, Stephen J.
    Siston, Robert A.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (07) : 969 - 975
  • [28] The influence of malrotation and femoral component material on patellofemoral wear during gait
    Vanbiervliet, J.
    Bellemans, J.
    Verlinden, C.
    Luyckx, J. -P.
    Labey, L.
    Innocenti, B.
    Vandenneucker, H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (10): : 1348 - 1354
  • [29] The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait AN IN VITRO BIOMECHANICAL STUDY
    Verlinden, C.
    Uvin, P.
    Labey, L.
    Luyckx, J. P.
    Bellemans, J.
    Vandenneucker, H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (05): : 737 - 742
  • [30] Kinematics of posterior cruciate ligament-retaining and -substituting total knee arthroplasty
    Victor, J
    Banks, S
    Bellemans, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (05): : 646 - 655