Influence of Contrast Material Temperature on Patient Comfort and Image Quality in Computed Tomography of the Abdomen A Randomized Controlled Trial

被引:3
|
作者
Martens, Bibi [1 ,2 ]
Wildberger, Joachim E. [1 ,2 ]
Van Kuijk, Sander M. J. [3 ]
De Vos-Geelen, Judith [4 ,5 ]
Jeukens, Cecile R. L. P. N. [1 ]
Mihl, Casper [1 ,2 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, P Debyelaan 25 POB 5800, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, CARIM Sch Cardiovasc Dis, Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Clin Epidemiol & Med Technol Assessment, Maastricht, Netherlands
[4] Maastricht UMC, Div Med Oncol, Dept Internal Med, Maastricht, Netherlands
[5] Maastricht UMC, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
关键词
multidetector computed tomography; diagnostic imaging; abdomen; contrast media; image quality; contrast material warming; discomfort; HEPATIC DYNAMIC CT; MEDIA VISCOSITY; ANGIOGRAPHY; ENHANCEMENT; INJECTION; FLOW;
D O I
10.1097/RLI.0000000000000807
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: International guideline recommendations on safe use of contrast media (CM) are conflicting regarding the necessity to prewarm iodinated CM. Purpose: Aim of the study was to evaluate the effects of room temperature CM compared with prewarmed CM on image quality, safety, and patient comfort in abdominal computed tomography (CT). Methods: CATCHY (Contrast Media Temperature and Patient Comfort in Computed Tomography of the Abdomen) is a double-blinded, randomized noninferiority trial. Between February and August 2020, 218 participants referred for portal venous abdominal CTwere prospectively and randomly assigned to 1 of 2 groups. All patients received iopromide at 300 mg I/mL: group 1 at room temperature (similar to 23 degrees C [similar to 73 degrees F]) and group 2 prewarmed to body temperature (37 degrees C [99 degrees F]). A state-of-the-art individualized CM injection protocol was used, based on body weight and adapted to tube voltage. Primary outcome was absolute difference in mean liver attenuation between groups, calculated with a 2-sided 95% confidence interval. The noninferiority margin was set at -10 HU. Secondary outcomes were objective (signal-to-noise ratio and contrast-to-noise ratio) and subjective image quality; CMextravasations and other adverse events; and participant comfort (5-point scale questionnaire) and pain (numeric rating scale). This trial is registered with ClinicalTrials.gov (NCT04249479). Results: The absolute difference in mean attenuation between groups was + 4.23 HU (95% confidence interval, +0.35 to +8.11; mean attenuation, 122.2 +/- 13.1 HU in group 1, 118.0 +/- 15.9 HU in group 2; P = 0.03). Signalto-noise ratio, contrast-to-noise ratio, and subjective image quality were not significantly different between groups (P = 0.53, 0.23, and 0.99 respectively). Contrast extravasation occurred in 1 patient (group 2), and no other adverse events occurred. Comfort scores were significantly higher in group 1 than in group 2 (P = 0.03); pain did not significantly differ (perceived P > 0.99; intensity P = 0.20). Conclusions: Not prewarming iodinated CM was found noninferior in abdominal CT imaging. Prewarming conferred no beneficial effect on image quality, safety, and comfort, and might therefore no longer be considered a prerequisite in state-of-the art injection protocols for parenchymal imaging.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 50 条
  • [31] Effects of the Use of Automatic Tube Current Modulation on Patient Dose and Image Quality in Computed Tomography
    Yurt, Aysegul
    Ozsoykal, Ismail
    Obuz, Funda
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2019, 28 (03) : 96 - 103
  • [32] Indirect Computed Tomography Venography With a Low-Tube-Voltage Technique: Reduction in the Radiation and Contrast Material Dose-A Prospective Randomized Study
    Oda, Seitaro
    Utsunomiya, Daisuke
    Awai, Kazuo
    Takaoka, Hiroko
    Nakaura, Takeshi
    Katahira, Kazuhiro
    Morishita, Syoji
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (05) : 631 - 636
  • [33] A randomized controlled trial of multi-slice coronary computed tomography for evalation of acute chest pain
    Goldstein, James A.
    Gallagher, Michael J.
    O'Neill, William W.
    Ross, Michael A.
    O'Neil, Brian J.
    Raff, Gilbert L.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (08) : 863 - 871
  • [34] Assessing the influence of X-ray spectrum on image quality in abdominal computed tomography scans
    El Mansouri, M'hamed
    Talbi, Mohammed
    Khatar, Zakaria
    Nhila, Oussama
    Sekkat, Hamza
    Tahiri, Zakaria
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2024, 179 (9-10): : 1178 - 1187
  • [35] Influence of tube voltage on image quality in non-contrast photon-counting computed tomography of the head: Comparison of 120 kVp and 140 kVp
    Schoenbeck, Denise
    Kroeger, Jan Robert
    Woeltjen, Matthias Michael
    Niehoff, Julius Henning
    Moenninghoff, Christoph
    Goertz, Lukas
    Borggrefe, Jan
    Michael, Arwed Elias
    NEURORADIOLOGY JOURNAL, 2025,
  • [36] Dual-energy computed tomography pulmonary angiography with ultra-low dose contrast administration: Comparison of image quality with standard computed tomography pulmonary angiography
    Celtikci, Pinar
    Hekimoglu, Koray
    Kahraman, Gokhan
    Haberal, Kemal Murat
    Kilic, Dalokay
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 30 (04): : 549 - 556
  • [37] Prospective Randomized Trial of Iohexol 350 Versus Meglumine Sodium Diatrizoate as an Oral Contrast Agent for Abdominopelvic Computed Tomography
    Peterson, Christine M.
    Lin, Michael
    Pilgram, Thomas
    Heiken, Jay P.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (02) : 202 - 205
  • [38] Patient dose and image quality from mega-voltage cone beam computed tomography imaging
    Gayou, Olivier
    Parda, David S.
    Johnson, Mark
    Miften, Moyed
    MEDICAL PHYSICS, 2007, 34 (02) : 499 - 506
  • [39] Changing the Patient's Position: Pitfalls and Benefits for Radiation Dose and Image Quality of Computed Tomography in Polytrauma
    Graef, Jessica
    Bressem, Keno K.
    Asbach, Patrick
    Hamm, Bernd
    Niehues, Stefan M.
    DIAGNOSTICS, 2022, 12 (11)
  • [40] Comparison of iodixanol 320 and iohexol 350 in image quality during 64-slice multidetector computed tomography: Prospective randomized study
    Choi, Tae-Young
    Woo, Vincent
    Gupta, Mohit
    Sourayanezhad, Souraya
    Li, Dong
    Mao, Song S.
    Budoff, Matthew
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 158 (01) : 134 - 138