Impact of board width on in-plane shear stiffness of cross-laminated timber

被引:11
作者
Turesson, Jonas [1 ]
Berg, Sven [1 ]
Ekevad, Mats [1 ]
机构
[1] Lulea Univ Technol, Div Wood Technol, SE-93187 Skelleftea, Sweden
关键词
CLT; In-plane shear modulus; In-plane shear stiffness; Finite element method; CLT board width; CLT layer thickness; CLT shear modulus; Board gap;
D O I
10.1016/j.engstruct.2019.05.090
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Board width-to-thickness ratios in non-edge-glued cross laminated timber (CLT) panels influence the in-plane shear stiffness of the panel. The objective is to show the impact of board width-to-thickness ratios for 3- and 5-layer CLT panels. Shear stiffnesses were calculated using finite element analysis and are shown as reduction factors relative to the shear stiffnesses of edge-glued CLT panels. Board width-to-thickness ratios were independently varied for outer and inner layers. Results show that the reduction factor lies in the interval of 0.6 to 0.9 for most width-to-thickness ratios. Results show also that using boards with low width-to-thickness ratios give low reduction factors. The calculated result differed by 2.9% compared to existing experimental data.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] In-plane Shear Modulus of Cross-laminated Timber by Diagonal Compression Test
    Berg, Sven
    Turesson, Jonas
    Ekevad, Mats
    Bjornfot, Anders
    BIORESOURCES, 2019, 14 (03) : 5559 - 5572
  • [2] Out-of-plane cross-angle bending stiffness of cross-laminated timber
    Zhang, Xiaoyue
    Niu, Binjie
    Cheng, Alexandra
    Bayat, Mohammad
    Tannert, Thomas
    ENGINEERING STRUCTURES, 2024, 319
  • [3] Comparison of Test Methodologies for Computing Bending and Shear Stiffness of Cross-Laminated Timber
    Hematabadi, Hojat
    Hindman, Daniel P.
    JOURNAL OF TESTING AND EVALUATION, 2021, 49 (03) : 1533 - 1549
  • [4] Production and In-Plane Compression Mechanics of Alternatively Angled Layered Cross-Laminated Timber
    Buck, Dietrich
    Hagman, Olle
    BIORESOURCES, 2018, 13 (02): : 4029 - 4045
  • [5] Diaphragm shear and diagonal compression testing of cross-laminated timber
    Sharifi, Jonas
    Sharifi, Zahra
    Berg, Sven
    Ekevad, Mats
    SN APPLIED SCIENCES, 2021, 3 (11):
  • [6] Diaphragm shear and diagonal compression testing of cross-laminated timber
    Jonas Sharifi
    Zahra Sharifi
    Sven Berg
    Mats Ekevad
    SN Applied Sciences, 2021, 3
  • [7] Ultimate failure load analysis of cross-laminated timber panels subjected to in-plane compression
    Heinisuo, Markku
    Pajunen, Sami
    Aspila, Aku
    STRUCTURES, 2023, 47 : 1558 - 1565
  • [8] Effective Measuring Area and Test Protocol in Picture Frame Method to Measure In-plane Shear Modulus of Cross-laminated Timber
    Kim, Jiyong
    Ahn, Kyung-Sun
    Pang, Sung-Jun
    Song, Da-Bin
    Kim, Chul-Ki
    Kim, Kwangmo
    Shim, Kugbo
    Kim, Keon-Ho
    Oh, Jung-Kwon
    Journal of the Korean Wood Science and Technology, 2024, 52 (06): : 605 - 617
  • [9] Study on in-plane compressive performance of cross-laminated bamboo and timber (CLBT) wall elements
    Li, Hao
    Wang, Libin
    Wang, Brad Jianhe
    Wei, Yang
    EUROPEAN JOURNAL OF WOOD AND WOOD PRODUCTS, 2023, 81 (02) : 343 - 355
  • [10] Experimental and numerical investigations of cross-laminated timber elements at in-plane beam loading conditions
    Jelec, Mario
    Danielsson, Henrik
    Rajcic, Vlatka
    Serrano, Erik
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 206 : 329 - 346