The levitation voltage of the conducting/non conducting particle in the SF6 gas filled electrode gap is high under DC voltage compared with the AC voltage. The levitation voltage increases with frequency of the supply voltage. Particle levitation voltage marginally increases with increase in THD of the harmonic AC voltage. The levitation voltage of the particle increases as and when the barrier is moved towards the high voltage electrode. No polarity dependency is observed on levitation voltage under DC voltages. Percentage of filler content in epoxy nanocomposites has high impact on levitation voltage of the particle. The analysis of levitation voltage with epoxy nanocomposites indicates that up to 3 wt% of MgO added specimen, the levitation voltage is high and above which a marginal reduction in levitation voltage of particle in SF6 gas medium is observed. The UHF signal magnitude caused by the particle movement process increases with the applied voltage. Also, the extinction voltage of particle movement is lower than the levitation voltage. Also, with increase of applied voltage, on levitation, the magnitude of UHF signal increases. However, on reducing the applied voltage, the UHF signal magnitude is much higher than onward application of voltage. This characteristics is almost the same under AC and DC voltages. The FFT analysis of UHF signal formed due to particle under AC and DC voltages, at the point of inception has dominant frequency at around 1 GHz. When the applied voltage is increased, especially under DC voltages, the FFT analysis of UHF signal formed indicates energy content in the band 2-3 GHz is increased, indicating indirectly, the rate of charge transfer due to particle movement with opposite electrode is high under DC voltages. The FFT analysis of UHF signal formed by non-conducting particle under high frequencies have the energy content increased in the range 2-5 GHz. PRPD analysis indicates that PD activity is observed in the entire phase of the applied AC voltage, irrespective of harmonics and THDs. The number of PD occurrence is high where the rate of rise of supply voltage is high.
引用
收藏
页码:1429 / 1438
页数:10
相关论文
共 50 条
  • [31] Surface Partial Discharge Characteristics in SF6 under AC and Switching Impulse Superimposed Voltage
    He C.
    Zhang Q.
    Cao D.
    Yuan W.
    Li J.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (08): : 1807 - 1817
  • [32] Partial discharge behavior of protrusion on high voltage conductor in GIS/GIL under high voltage direct current: Comparison of SF6 and SF6 alternative gases
    Toigo, C.
    Vu-Cong, T.
    Jacquier, F.
    Girodet, A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (01) : 140 - 147
  • [33] Comparison of partial discharge characteristics for different defect types in SF6 gas insulation system
    Mansour, D. A.
    Okusu, T.
    Nishizawa, K.
    Kojima, H.
    Hayakawa, N.
    Endo, F.
    Okubo, H.
    2008 12TH INTERNATIONAL MIDDLE EAST POWER SYSTEM CONFERENCE, VOLS 1 AND 2, 2008, : 224 - 228
  • [34] Discharge Characteristics of SF6 Gas with and without Insulators under VFTO and Lightning Impulse Voltage
    Zhang, Lu
    Mao, Chen
    Sun, Lei
    Wu, Jingfeng
    Zhang, Xiaolan
    Zhang, Qiaogen
    2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 620 - 624
  • [35] Partial Discharge Recognition through an Analysis of SF6 Decomposition Products Part 1: Decomposition Characteristics of SF6 under Four Different Partial Discharges
    Tang, Ju
    Liu, Fan
    Zhang, Xiaoxing
    Meng, Qinghong
    Zhou, Jiabin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (01) : 29 - 36
  • [36] Research on partial discharge diagnosis of GIS by decomposed gas of SF6
    Luo, Li-Shi
    Yao, Wen-Jun
    Wang, Jun
    Li, Cheng-Rong
    Zheng, Shu-Sheng
    Wu, Xiao-Bo
    Mao, Ting
    Dianwang Jishu/Power System Technology, 2010, 34 (05): : 225 - 230
  • [37] Deterioration characteristics of insulation subjected to partial discharge in SF6 gas
    Okabe, S
    Kawashima, T
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 792 - 797
  • [38] OVERVOLTAGE DEPENDENCE OF PARTIAL DISCHARGE IN COMPRESSED SF6 GAS.
    Nagata, Shigeyuki
    Tanaka, Ikuo
    Inuishi, Yoshio
    1600,
  • [39] Decomposition Characteristics of SF6/N2 Under Partial Discharge of Different Degrees
    Li, Chen
    Tang, Ju
    Zhao, Zhiqiang
    Li, Haotian
    Miao, Yulong
    Zeng, Fuping
    IEEE ACCESS, 2020, 8 : 192312 - 192319
  • [40] Partial Discharges in SF6 Gas Filled Void under Standard Aperiodic and Oscillating Switching Impulses
    Ren, Ming
    Dong, Ming
    Qiu, Aici
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (01) : 262 - 272