Diagnostic accuracy of coronary CT angiography using 3rd-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

被引:26
作者
Mangold, Stefanie [1 ,2 ]
Wichmann, Julian L. [1 ,3 ]
Schoepf, U. Joseph [1 ,4 ]
Caruso, Damiano [1 ,5 ]
Tesche, Christian [1 ,6 ]
Steinberg, Daniel H. [4 ]
Varga-Szemes, Akos [1 ]
Stubenrauch, Andrew C. [1 ]
Bayer, Richard R., II [4 ]
Biancalana, Matthew [1 ]
Nikolaou, Konstantin [2 ]
De Cecco, Carlo N. [1 ]
机构
[1] Med Univ South Carolina, Div Cardiovasc Imaging, Dept Radiol & Radiol Sci, Ashley River Tower,25 Courtenay Dr, Charleston, SC 29425 USA
[2] Eberhard Karls Univ Tuebingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[3] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[4] Med Univ South Carolina, Div Cardiol, Dept Med, Charleston, SC 29425 USA
[5] Univ Rome Sapienza, Dept Radiol Sci Oncol & Pathol, Rome, Italy
[6] Heart Ctr Munich Bogenhausen, Dept Cardiol, Munich, Germany
关键词
Coronary CT angiography; Dual-source CT; Automated tube voltage selection; Diagnostic accuracy; Obesity; SPIRAL COMPUTED-TOMOGRAPHY; MODELED ITERATIVE RECONSTRUCTION; IMPROVED IMAGE QUALITY; RADIATION-EXPOSURE; ARTERY-DISEASE; CONTRAST AGENT; PERFORMANCE; FEASIBILITY; REDUCTION; COMMITTEE;
D O I
10.1007/s00330-016-4601-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate diagnostic accuracy of 3(rd)-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (< 30 kg/m(2), n = 37) and B (a 30 kg/m(2), n = 39) and based on tube voltage in groups C (< 120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (a 50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3(rd)-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. aEuro cent Coronary CTA provides high diagnostic accuracy in non-obese and obese patients. aEuro cent Diagnostic accuracy between obese and non-obese patients showed no significant difference. aEuro cent < 120 kV studies were performed in 44 % of obese patients. aEuro cent Current radiation dose-saving approaches can be applied independent of body habitus.
引用
收藏
页码:2298 / 2308
页数:11
相关论文
共 35 条
  • [31] Multidetector computed tomography for the diagnosis of coronary artery disease: A systematic review
    Stein, PD
    Beemath, A
    Kayali, F
    Skaf, E
    Sanchez, J
    Olson, RE
    [J]. AMERICAN JOURNAL OF MEDICINE, 2006, 119 (03) : 203 - 216
  • [32] Application of low tube voltage coronary CT angiography with low-dose iodine contrast agent in patients with a BMI of 26-30 kg/m2
    Sun, G.
    Hou, Y. B.
    Zhang, B.
    Yu, L.
    Li, S. X.
    Tan, L. L.
    Chen, D. J.
    [J]. CLINICAL RADIOLOGY, 2015, 70 (02) : 138 - 145
  • [33] Image quality and radiation dose of low dose coronary CT angiography in obese patients: Sinogram affirmed iterative reconstruction versus filtered back projection
    Wang, Rui
    Schoepf, U. Joseph
    Wu, Runze
    Reddy, Ryan P.
    Zhang, Chuanchen
    Yu, Wei
    Liu, Yi
    Zhang, Zhaoqi
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3141 - 3145
  • [34] Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT
    Winklehner, Anna
    Gordic, Sonja
    Lauk, Eliane
    Frauenfelder, Thomas
    Leschka, Sebastian
    Alkadhi, Hatem
    Husarik, Daniela B.
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (08) : 2346 - 2353
  • [35] Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience
    Zhang, Long Jiang
    Qi, Li
    Wang, Jing
    Tang, Chun Xiang
    Zhou, Chang Sheng
    Ji, Xue Man
    Spearman, James V.
    De Cecco, Carlo Nicola
    Meinel, Felix G.
    Schoepf, U. Joseph
    Lu, Guang Ming
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (07) : 1537 - 1546