An assay for inorganic mercury(II) based on its post-catalytic enhancement effect on the potassium permanganate-luminol system

被引:10
作者
Hu, Shangwei
Liu, Weibing
Huang, Yuming [1 ]
Shu, Weiqun
Cao, Jia
机构
[1] SW Univ, Coll Chem & Chem Engn, Key Lab Three Gorges Reservoir Reg Ecoenvironm, Minist Educ, Chongqing 400715, Peoples R China
[2] Third Mil Med Univ, Dept Environm Hlth, Chongqing 400038, Peoples R China
关键词
environmental analysis; chemiluminescence; Hg2+;
D O I
10.1002/bio.914
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A strong chemiluminescence (CL) response is observed when potassium permanganate solution is injected into basic luminol solution. When the CL reaction terminates, subsequent injection of Hg2+ solution into the reaction mixture results in a new CL reaction. Based on the post-catalytic enhancement effect of Hg2+ on the potassium permanganate-luminol system in basic media, a fast and simple CL-coupled flow injection analysis for the determination of Hg2+ was developed. In optimum conditions, CL intensity is proportional to Hg2+ concentration over the range 1.0 x 10(-8)-1.0 x 10(-5) g/mL, with a detection limit of 2.0 x 10(-9) g/mL. The relative standard deviation (RSD) is 3.6% for 1.0 x 10(-7) g/mL Hg2+ (n = 11). After pretreatment with sulphydryl cotton fibre, environmental water samples were analysed by the proposed method for total mercury determination with satisfactory results. The results were in good agreement with those given by hydride generation-cold vapour atomic absorption spectrometry (HG-CVAAS). Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 21 条
[1]   UV digestion of seawater samples prior to the determination of copper using flow injection with chemiluminescence detection [J].
Achterberg, EP ;
Braungardt, CB ;
Sandford, RC ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 2001, 440 (01) :27-36
[2]   Improved preparation of small biological samples for mercury analysis using cold vapor atomic absorption spectroscopy. [J].
Adair, BM ;
Cobb, GP .
CHEMOSPHERE, 1999, 38 (12) :2951-2958
[3]  
BRADAO GP, 2005, SPECTROCHIM ACTA B, V60, P625
[4]   Continuous shipboard determination of Fe(II) in polar waters using flow injection analysis with chemiluminescence detection [J].
Croot, PL ;
Laan, P .
ANALYTICA CHIMICA ACTA, 2002, 466 (02) :261-273
[5]   Cloud-point extraction/preconcentration on-line flow injection method for mercury determination [J].
Garrido, M ;
Di Nezio, MS ;
Lista, AG ;
Palomeque, M ;
Band, BSF .
ANALYTICA CHIMICA ACTA, 2004, 502 (02) :173-177
[6]  
HABIB B, 2001, TALANTA, V55, P1141
[7]   Rapid determination of total mercury in treated waste water by cold vapor atomic absorption spectrometry in alkaline medium with sodium hypochlorite solution [J].
Kagaya, S ;
Kuroda, Y ;
Serikawa, Y ;
Hasegawa, K .
TALANTA, 2004, 64 (02) :554-557
[8]   Chemiluminescence flow injection analysis of reducing agents based on the luminol reaction [J].
Kubo, H ;
Toriba, A .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :345-349
[9]  
Kumiko S., 1998, ANAL CHIM ACTA, V376, P247
[10]  
Liu W., 1999, LIHUA JIANYAN HUAXUE, V35, P457