Precision of regional wall motion estimates from ultra-low-dose cardiac CT using SQUEEZ

被引:7
作者
Pourmorteza, Amir [1 ]
Keller, Noemie [2 ]
Chen, Richard [2 ]
Lardo, Albert [2 ,3 ]
Halperin, Henry [2 ,3 ]
Chen, Marcus Y. [4 ]
McVeigh, Elliot [5 ,6 ,7 ]
机构
[1] Emory Univ, Dept Radiol & Imaging Sci, Winship Canc Insititute, Atlanta, GA 30322 USA
[2] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Sch Med, Dept Med, Baltimore, MD 21205 USA
[4] NHLBI, Adv Cardiovasc Imaging Lab, Cardiopulm Branch, NIH, Bldg 10, Bethesda, MD 20892 USA
[5] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92103 USA
[6] Univ Calif San Diego, Dept Med, San Diego, CA 92103 USA
[7] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
基金
美国国家卫生研究院;
关键词
Myocardial function; CT noise; Wall motion abnormality; Regional cardiac function; SQUEEZ; ACUTE CHEST-PAIN; COMPUTED-TOMOGRAPHY; ITERATIVE RECONSTRUCTION; EMERGENCY-DEPARTMENT; ROMICAT TRIAL; ANGIOGRAPHY; CARE;
D O I
10.1007/s10554-018-1332-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Resting regional wall motion abnormality (RWMA) has significant prognostic value beyond the findings of computed tomography (CT) coronary angiography. Stretch quantification of endocardial engraved zones (SQUEEZ) has been proposed as a measure of regional cardiac function. The purpose of the work reported here was to determine the effect of lowering the radiation dose on the precision of automatic SQUEEZ assessments of RWMA. Chronic myocardial infarction was created by a 2-h occlusion of the left anterior descending coronary artery in 10 swine (heart rates 80-100, ejection fraction 25-57%). CT was performed 5-11 months post infarct using first-pass contrast enhanced segmented cardiac function scans on a 320-detector row scanner at 80 kVp/500 mA. Images were reconstructed at end diastole and end systole with both filtered back projection and using the "standard" adaptive iterative dose reduction (AIDR) algorithm. For each acquisition, 9 lower dose acquisitions were created. End systolic myocardial function maps were calculated using SQUEEZ for all noise levels and contrast-to-noise ratio (CNR) between the left ventricle blood and myocardium was calculated as a measure of image quality. For acquisitions with CNR > 4, SQUEEZ could be estimated with a precision of +/- 0.04 (p < 0.001) or 5.7% of its dynamic range. The difference between SQUEEZ values calculated from AIDR and FBP images was not statistically significant. Regional wall motion abnormality can be quantified with good precision from low dose acquisitions, using SQUEEZ, as long as the blood-myocardium CNR stays above 4.
引用
收藏
页码:1277 / 1286
页数:10
相关论文
共 18 条
  • [1] Angel E, TOSHIBA AM MED SYSTE
  • [2] Behar JM, 2015, EUROPACE, V17, pv10
  • [3] Comprehensive use of cardiac computed tomography to guide left ventricular lead placement in cardiac resynchronization therapy
    Behar, Jonathan M.
    Rajani, Ronak
    Pourmorteza, Amir
    Preston, Rebecca
    Razeghi, Orod
    Niederer, Steve
    Adhya, Shaumik
    Claridge, Simon
    Jackson, Tom
    Sieniewicz, Ben
    Gould, Justin
    Carr-White, Gerry
    Razavi, Reza
    McVeigh, Elliot
    Rinaldi, Christopher Aldo
    [J]. HEART RHYTHM, 2017, 14 (09) : 1364 - 1372
  • [4] Boas FE., 2012, IMAGING MED, V4, P229, DOI DOI 10.2217/IIM.12.13
  • [5] Coronary CT angiography versus standard of care for assessment of chest pain in the emergency department
    Cury, Ricardo C.
    Budoff, Matthew
    Taylor, Allen J.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (02) : 79 - 82
  • [6] Triage of Patients Presenting With Chest Pain to the Emergency Department: Implementation of Coronary CT Angiography in a Large Urban Health Care System
    Cury, Ricardo C.
    Feuchtner, Gudrun M.
    Batlle, Juan C.
    Penato, Constantino S.
    Janowitz, Warren
    Katzen, Barry T.
    Ziffer, Jack A.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 57 - 65
  • [7] Fan Y, 2012, IEEE NUCL SCI CONF R, P3641
  • [8] SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
    Halliburton, Sandra S.
    Abbara, Suhny
    Chen, Marcus Y.
    Gentry, Ralph
    Mahesh, Mahadevappa
    Raff, Gilbert L.
    Shaw, Leslee J.
    Hausleiter, Joerg
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (04) : 198 - 224
  • [9] Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease
    Hou, Yang
    Ma, Yue
    Fan, Weipeng
    Wang, Yuke
    Yu, Mei
    Vembar, Mani
    Guo, Qiyong
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (01) : 3 - 11
  • [10] The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT
    Hou, Yang
    Xu, Shu
    Guo, Wenli
    Vembar, Mani
    Guo, Qiyong
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 3905 - 3911