Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring

被引:173
|
作者
Kim, Joshua [1 ]
Chou, En-Fan [2 ]
Le, Jamie [2 ]
Wong, Sabrina [2 ]
Chu, Michael [2 ]
Khine, Michelle [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Mat Sci & Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
关键词
blood pressure; flexible electronics; health sensors; pressure sensors; wearable electronics; ARTERIAL PULSE; VARIABILITY; TONOMETRY; WAVE;
D O I
10.1002/adhm.201900109
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wrinkled gold thin films on elastomeric substrates are used as robust parallel plate electrodes for soft capacitive pressure sensors. The wrinkled structures create a robust integration with the polymer, allowing repeated normal force to deform the thin film without failure. By incorporating microridged structures that support the counter electrodes to create air cavities within the elastomeric dielectric layer, pressure sensitivity is further increased to 0.148 kPa(-1) over a wide dynamic range of up to 10 kPa. The wide dynamic range and pressure sensitivity of the pressure sensor allow for consistent measurements of the pressure exerted by the radial artery located on the wrist. The soft capacitive pressure sensor displays comparable results when tested against an FDA approved device (Clearsight, Edwards Lifesciences, Irvine, CA) measuring beat-to-beat blood pressure. These soft pressure sensors using wrinkled thin films, therefore, illustrate considerable potential to continuously monitor beat-to-beat blood pressure.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Beat-to-Beat Heart Rate and Blood Pressure Variability and Hypertensive Disease in Pregnancy
    Flood, Pamela
    McKinley, Paula
    Monk, Catherine
    Muntner, Paul
    Colantonio, Lisandro D.
    Goetzl, Laura
    Hatch, Maureen
    Sloan, Richard P.
    AMERICAN JOURNAL OF PERINATOLOGY, 2015, 32 (11) : 1050 - 1058
  • [42] Increasing sleep duration to lower beat-to-beat blood pressure: a pilot study
    Haack, Monika
    Serrador, Jorge
    Cohen, Daniel
    Simpson, Norah
    Meier-Ewert, Hans
    Mullington, Janet M.
    JOURNAL OF SLEEP RESEARCH, 2013, 22 (03) : 295 - 304
  • [43] Changes in beat-to-beat blood pressure and pulse rate variability following stroke
    Arash Abiri
    En-Fan Chou
    Weining Shen
    Mark J. Fisher
    Michelle Khine
    Scientific Reports, 13
  • [44] TRACKING-CUFF SYSTEM FOR BEAT-TO-BEAT RECORDING OF BLOOD-PRESSURE
    SHAPIRO, D
    GREENSTADT, L
    LANE, JD
    RUBINSTEIN, E
    PSYCHOPHYSIOLOGY, 1981, 18 (02) : 129 - 136
  • [45] Beat-to-beat blood-pressure measurements applied in studies on mental workload
    vanRoon, AM
    Mulder, LJM
    Veldman, JBP
    Mulder, G
    HOMEOSTASIS IN HEALTH AND DISEASE, 1995, 36 (5-6): : 316 - 324
  • [46] Postpartum Beat-to-Beat Systolic Blood Pressure Variability in Preeclampsia with Severe Features
    van Wingerden, Anne-Sophie
    Katsidoniotaki, Maria
    Haghighi, Noora
    Almonte, Casandra
    Woolcock, Helen
    Valdes, Eduard
    Alian, Aymen S.
    Booker, Whitney A.
    Bello, Natalie
    Marshall, Randolph
    Kougioumtzoglou, Ioannis
    Petersen, Nils
    Miller, Eliza C.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 230 (01) : S611 - S612
  • [47] ELECTRONIC CIGARETTE ACUTELY INCREASES BLOOD PRESSURE IN HYPERTENSIVE PATIENTS. EVALUATION BY NON - INVASIVE CONTINUOUS (BEAT-TO-BEAT) BLOOD PRESSURE MONITORING
    Crippa, Giuseppe
    Balordi, Valentina
    Bravi, Elena
    Fontana, Manuela
    JOURNAL OF HYPERTENSION, 2018, 36 : E168 - E168
  • [48] Changes in beat-to-beat blood pressure and pulse rate variability following stroke
    Abiri, Arash
    Chou, En-Fan
    Shen, Weining
    Fisher, Mark J.
    Khine, Michelle
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [49] The beat-to-beat relationship between pulse transit time and systolic blood pressure
    Poon, Carmen C. Y.
    Zhang, Yuan-Ting
    Wong, George
    Poon, Wai Sang
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 357 - +
  • [50] Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification
    Farzam, Ramin
    Azad, Mohammad Hasan
    Moghaddam, Hamid Abrishami
    Forouzanfar, Mohamad
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (02) : 619 - 629