Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring

被引:185
作者
Kim, Joshua [1 ]
Chou, En-Fan [2 ]
Le, Jamie [2 ]
Wong, Sabrina [2 ]
Chu, Michael [2 ]
Khine, Michelle [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Mat Sci & Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
关键词
blood pressure; flexible electronics; health sensors; pressure sensors; wearable electronics; ARTERIAL PULSE; VARIABILITY; TONOMETRY; WAVE;
D O I
10.1002/adhm.201900109
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wrinkled gold thin films on elastomeric substrates are used as robust parallel plate electrodes for soft capacitive pressure sensors. The wrinkled structures create a robust integration with the polymer, allowing repeated normal force to deform the thin film without failure. By incorporating microridged structures that support the counter electrodes to create air cavities within the elastomeric dielectric layer, pressure sensitivity is further increased to 0.148 kPa(-1) over a wide dynamic range of up to 10 kPa. The wide dynamic range and pressure sensitivity of the pressure sensor allow for consistent measurements of the pressure exerted by the radial artery located on the wrist. The soft capacitive pressure sensor displays comparable results when tested against an FDA approved device (Clearsight, Edwards Lifesciences, Irvine, CA) measuring beat-to-beat blood pressure. These soft pressure sensors using wrinkled thin films, therefore, illustrate considerable potential to continuously monitor beat-to-beat blood pressure.
引用
收藏
页数:9
相关论文
共 48 条
[1]   Comparison of the non-invasive Nexfin® monitor with conventional methods for the measurement of arterial blood pressure in moderate risk orthopaedic surgery patients [J].
Balzer, Felix ;
Habicher, Marit ;
Sander, Michael ;
Sterr, Julian ;
Scholz, Stephanie ;
Feldheiser, Aarne ;
Mueller, Michael ;
Perka, Carsten ;
Treskatsch, Sascha .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2016, 44 (04) :832-843
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   SYSTEMATIC DIFFERENCE BETWEEN BLOOD-PRESSURE READINGS CAUSED BY CUFF TYPE [J].
BOVET, P ;
HUNGERBUHLER, P ;
QUILINDO, J ;
GRETTVE, ML ;
WAEBER, B ;
BURNAND, B .
HYPERTENSION, 1994, 24 (06) :786-792
[4]   Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysis [J].
Cheng, Hao-Min ;
Lang, Dora ;
Tufanaru, Catalin ;
Pearson, Alan .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (05) :1867-1876
[5]   Micropatterned Pyramidal Ionic Gels for Sensing Broad-Range Pressures with High Sensitivity [J].
Cho, Sung Hwan ;
Lee, Seung Won ;
Yu, Seunggun ;
Kim, Hyeohn ;
Chang, Sooho ;
Kang, Donyoung ;
Hwang, Ihn ;
Kang, Han Sol ;
Jeong, Beomjin ;
Kim, Eui Hyuk ;
Cho, Suk Man ;
Kim, Kang Lib ;
Lee, Hyungsuk ;
Shim, Wooyoung ;
Park, Cheolmin .
ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (11) :10128-10135
[6]   Non-invasive continuous blood pressure monitoring: a review of current applications [J].
Chung, Elena ;
Chen, Guo ;
Alexander, Brenton ;
Cannesson, Maxime .
FRONTIERS OF MEDICINE, 2013, 7 (01) :91-101
[7]   Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring [J].
Dagdeviren, Canan ;
Su, Yewang ;
Joe, Pauline ;
Yona, Raissa ;
Liu, Yuhao ;
Kim, Yun-Soung ;
Huang, YongAn ;
Damadoran, Anoop R. ;
Xia, Jing ;
Martin, Lane W. ;
Huang, Yonggang ;
Rogers, John A. .
NATURE COMMUNICATIONS, 2014, 5
[8]  
desWilde R. B. P., 2016, ANAESTHESIA, V71, P788
[9]   A review on the Mullins effect [J].
Diani, Julie ;
Fayolle, Bruno ;
Gilormini, Pierre .
EUROPEAN POLYMER JOURNAL, 2009, 45 (03) :601-612
[10]   Mechanical Characterization of PDMS Films for the Optimization of Polymer Based Flexible Capacitive Pressure Microsensors [J].
Dinh, T. -H. -N. ;
Martincic, E. ;
Dufour-Gergam, E. ;
Joubert, P. -Y. .
JOURNAL OF SENSORS, 2017, 2017