Discriminating Between Loss of Excitation and Power Swings in Synchronous Generator Based on ANN

被引:12
作者
Barakat, Zeina A. [1 ]
Hajjar, Ammar A. [1 ]
Kherbek, Tarek [1 ]
Alhelou, Hassan Haes [1 ,2 ]
机构
[1] Tishreen Univ, Fac Mech & Elect Engn, Elect Power Engn Dept, Latakia City, Syria
[2] Isfahan Univ Technol, Dept Elect & Comp Engn ECE, Esfahan 8415683111, Iran
关键词
Synchronous generator; Loss of excitation; Power swing; Protection; Neural networks; Artificial neural network; Stable power swings; PATTERN-CLASSIFICATION;
D O I
10.1007/s40313-019-00464-z
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a newly designed scheme based on neural networks to detect loss of excitation (LOE) in synchronous generators. The proposed scheme uses more accurate mechanism and needs fewer parameters in order to achieve fast and reliable detection of LOE. Furthermore, being able to discriminate between LOE and stable power swings is a major concern to enhance the performance of traditional LOE protection. Therefore, the designed network is trained to discriminate between both cases clearly. For training and testing the proposed neural network, MATLAB program has been used for simulation. In addition, by using comparison analysis between the designed network and the previous ones and the traditional MHO relay, the results ensure that the proposed scheme has more secure and fast characters in detecting and discriminating LOE.
引用
收藏
页码:545 / 556
页数:12
相关论文
共 15 条
[1]   A Novel Approach to Detect the Synchronous Generator Loss of Excitation [J].
Amini, Mahdi ;
Davarpanah, Mahdi ;
Sanaye-Pasand, Majid .
IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) :1429-1438
[2]  
Aziz M.A., 2016, Indonesian J. Electr. Eng. Comput. Sci, V1, P300
[3]   LOSS OF EXCITATION PROTECTION FOR MODERN SYNCHRONOUS GENERATORS [J].
BERDY, J .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (05) :1457-1463
[4]  
Blackburn, 1954, J ELECT ENG, V73, P1008, DOI [10.1109/EE.1954.6439083, DOI 10.1109/EE.1954.6439083]
[5]   An Innovative Loss-of-Excitation Protection Based on the Fuzzy Inference Mechanism [J].
de Morais, Adriano P. ;
Cardoso, Ghendy, Jr. ;
Mariotto, L. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :2197-2204
[6]   Impact of Midpoint STATCOM on Generator Loss of Excitation Protection [J].
Elsamahy, Mohamed ;
Faried, Sherif Omar ;
Sidhu, Tarlochan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) :724-732
[7]  
Fan B., 2009, RES UL P LOSS OF EXC
[8]   Operation of synchronous generator LOE protection in the presence of shunt-FACTS [J].
Ghorbani, Amir ;
Mozafari, Babak ;
Soleymani, Soodabeh ;
Ranjbar, Ali Mohammad .
ELECTRIC POWER SYSTEMS RESEARCH, 2015, 119 :178-186
[9]  
Maason CR, 1949, T AIEE, V68, P1240
[10]   Identification of generator loss-of-excitation from power-swing conditions using a fast pattern classification method [J].
Pajuelo, Eli ;
Gokaraju, Ramakrishna ;
Sachdev, Mohindar S. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (01) :24-36