Application of factorial design to improve a FIA system for penicillin determination

被引:18
作者
Duarte, MMMB
Neto, GDO
Kubota, LT
Filho, JLL
Pimentel, MF
Lima, F
Lins, V
机构
[1] UNICAMP,INST QUIM,BR-13083970 CAMPINAS,SP,BRAZIL
[2] UFPE,DEPT ENGN QUIM,BR-50740521 RECIFE,PE,BRAZIL
[3] UFPE,DEPT BIOQUIM,BR-50740521 RECIFE,PE,BRAZIL
[4] INST TECNOL PERNAMBUCO,BR-50740521 RECIFE,PE,BRAZIL
关键词
chemometrics; penicillin; FIA; experimental design;
D O I
10.1016/S0003-2670(97)00291-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric FIA system for penicillin determination, employing penicillinase [E.C. 3.5.2.6] immobilized on silica gel, packed into a reactor, was improved by the use of statistically designed experiments. A two-level and three-factor factorial was used to find the best working conditions evaluating the influence of some parameters on the signal response of the system and the number of determinations per hour. These parameters were analyzed individually obtaining two level of the variables to be used in the factorial design: length of the reactor (1.5 and 2.0 cm), carrier flow rate (1.6 and 2.2 mi min(-1)) and sample volume (100 and 150 mu l). The pure error on the measurements was estimated by authentic repetitions. The ideal working conditions taking into account a compromise between the best response signal and the number of determinations per hour (with the same importance) being chosen the level of factors: length of reactor 1.5 cm, carrier flow rate 2.2 ml min(-1) and sample volume of 150 mu l. Under these conditions the system allowed to analyze was about 45 samples per hour, during 73 days, with a standard deviation of 2.4% at concentration range between 10(-1) and 10(-3) mol l(-1).
引用
收藏
页码:353 / 357
页数:5
相关论文
共 20 条
[1]  
BARROS BN, 1995, PLANEJAMENTO OTIMIZA, P299
[2]   PENICILLIN-G SENSOR BASED ON PENICILLIN AMIDASE COUPLED TO A FIELD-EFFECT TRANSISTOR [J].
BRAND, U ;
SCHEPER, T ;
SCHUGERL, K .
ANALYTICA CHIMICA ACTA, 1989, 226 (01) :87-97
[3]  
DESCRITOFORO G, 1984, ANAL CHEM, V56, P263
[4]  
DUARTE M, UNPUB
[5]   SINGLE FIBER-OPTIC FLUORESCENCE ENZYME-BASED SENSOR [J].
FUH, MRS ;
BURGESS, LW ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :433-435
[6]   EXPERIMENTAL FLUCTUATIONS OF FLOW-INJECTION SIGNALS [J].
GINE, MF ;
TUON, RL ;
KRUG, FJ ;
ARRUDA, MAZ .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :533-538
[7]   FLOW-INJECTION DETERMINATION OF PENICILLINS USING IMMOBILIZED PENICILLINASE IN A SINGLE BEAD STRING REACTOR [J].
GNANASEKARAN, R ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1985, 57 (06) :1005-1009
[8]   OPTIMIZATION OF A DIRECT-CURRENT PLASMA EMISSION ECHELLE SPECTROMETER [J].
HENDRICK, MS ;
MICHEL, RG .
ANALYTICA CHIMICA ACTA, 1987, 192 (02) :183-195
[9]   MULTIVARIATE CORRECTION OF CHEMICAL INTERFERENCES IN HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
HENRION, G ;
HENRION, R ;
HEBISCH, R ;
BOEDEN, B .
ANALYTICA CHIMICA ACTA, 1992, 268 (01) :115-122
[10]   EXPERIMENTAL OPTIMIZATION PROCEDURES IN THE DETERMINATION OF PHOSPHATE BY FLOW-INJECTION ANALYSIS [J].
JANSE, TAHM ;
VANDERWIEL, PFA ;
KATEMAN, G .
ANALYTICA CHIMICA ACTA, 1983, 155 (DEC) :89-102