Opening velocity, a novel parameter, for finger tapping test in patients with Parkinson's disease

被引:87
作者
Yokoe, M. [1 ,5 ]
Okuno, R. [4 ]
Hamasaki, T. [2 ,5 ]
Kurachi, Y. [3 ,5 ]
Akazawa, K. [6 ]
Sakoda, S. [1 ,5 ]
机构
[1] Osaka Univ, Dept Neurol, Grad Sch Med, Osaka, Japan
[2] Osaka Univ, Dept Med Stat, Grad Sch Med, Osaka, Japan
[3] Osaka Univ, Dept Pharmacol 2, Grad Sch Med, Osaka, Japan
[4] Setsunan Univ, Dept Elect & Elect Engn, Fac Engn, Osaka, Japan
[5] Osaka Univ, Ctr Adv Med Engn & Informat, Osaka, Japan
[6] Osaka Inst Technol, Dept Biomed Engn, Osaka 535, Japan
关键词
Parkinson's disease; Finger tapping; Accelerometer; Principal component analysis; MOTOR CONTROL; MOVEMENTS; BRADYKINESIA; VOLUNTARY; STIMULATION; IMPAIRMENT;
D O I
10.1016/j.parkreldis.2008.11.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: A new system consisting of an accelerometer and touch sensor was developed to find objective parameters for the finger tapping (FT) test in patients with Parkinson's disease (PD). Methods: We recruited sixteen patients with PD and thirty-two age-matched healthy volunteers (HVs). By using this new system, various parameters related to velocity, amplitude, rhythm and number in the FT test were measured in patients with PD and examined in comparison with those of HVs on the basis of the Unified Parkinson's Disease Rating Scale (UPDRS) FT score. Results: The new system allowed us to measure fourteen parameters of FT movement very easily, and a radar chart showed obvious differences in most of these parameters between HVs and patients with PD. Principal component analysis showed that fourteen parameters were classified into three components: (1) both mean and standard deviation (SD) of both amplitude and velocity, (2) number of FT for 60 s and mean FT interval, and (3) SD of FT interval. The first (velocity- and amplitude-related parameters) and third (rhythm-related parameters) components contributed to discrimination of PD from HVs. Maximum opening velocity (MoV) was the best of these parameters because of its sensitivity and association with the UPDRS FT score. Conclusions: A novel system for the FT test, which is compact, simple and efficient, has been developed. Velocity- and amplitude-related parameters were indicated to be valuable for evaluation of the FT test in patients with PD. In particular, we first propose that MoV is a novel marker for the FT test. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:440 / 444
页数:5
相关论文
共 28 条
[1]   Impairment of individual finger movements in Parkinson's disease [J].
Agostino, R ;
Currà, A ;
Giovannelli, M ;
Modugno, N ;
Manfredi, M ;
Berardelli, A .
MOVEMENT DISORDERS, 2003, 18 (05) :560-565
[2]   Clinical impairment of sequential finger movements in Parkinson's disease [J].
Agostino, R ;
Berardelli, A ;
Currà, A ;
Accornero, N ;
Manfredi, M .
MOVEMENT DISORDERS, 1998, 13 (03) :418-421
[3]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[4]  
[Anonymous], ANN NEUROL S
[5]   Amplitude and phase dynamics associated with acoustically paced finger tapping [J].
Boonstra, T. W. ;
Daffertshofer, A. ;
Peper, C. E. ;
Beek, Pj. .
BRAIN RESEARCH, 2006, 1109 :60-69
[6]  
Bronte-Stewart HM, 2000, MOVEMENT DISORD, V15, P36, DOI 10.1002/1531-8257(200001)15:1<36::AID-MDS1008>3.0.CO
[7]  
2-M
[8]   Quantification of index tapping regularity after stroke with tri-axial accelerometry [J].
Calautti, C. ;
Jones, P. S. ;
Persaud, N. ;
Guincestre, J. -Y. ;
Naccarato, M. ;
Warburton, E. A. ;
Baron, Jean-Claude .
BRAIN RESEARCH BULLETIN, 2006, 70 (01) :1-7
[9]   Temporal measures of human finger tapping: Effects of age [J].
Cousins, MS ;
Corrow, C ;
Finn, M ;
Salamone, JD .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1998, 59 (02) :445-449
[10]   Gravitational artifact in accelerometric measurements of tremor [J].
Elble, RJ .
CLINICAL NEUROPHYSIOLOGY, 2005, 116 (07) :1638-1643