Comparison of sample preparation methods for reliable plutonium and neptunium urinalysis using automatic extraction chromatography

被引:6
作者
Qiao, Jixin [1 ]
Xu, Yihong [1 ,2 ]
Hou, Xiaolin [1 ,3 ,4 ]
Miro, Manuel [5 ]
机构
[1] Tech Univ Denmark, Ctr Nucl Technol, DK-4000 Roskilde, Denmark
[2] Nanjing Univ, Key Lab Coastal & Isl Dev, Minist Educ, Nanjing 210093, Jiangsu, Peoples R China
[3] Chinese Acad Sci, Xian AMS Ctr, Xian, Peoples R China
[4] Chinese Acad Sci, SKLLQG, Inst Earth Environm, Xian, Peoples R China
[5] Univ Balear Islands, Fac Sci, Dept Chem, FI TRACE Grp, E-07122 Palma de Mallorca, Spain
关键词
Plutonium; Neptunium; Urine; Pre-concentration techniques; Lab-on-valve extraction chromatography; PLASMA-MASS SPECTROMETRY; RAPID-DETERMINATION; ANION-EXCHANGE; URINE; SEPARATION; ACTINIDES; ISOTOPES; PU-239; LEVEL; TRACE;
D O I
10.1016/j.talanta.2014.04.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes improvement and comparison of analytical methods for simultaneous determination of trace-level plutonium and neptunium in urine samples by inductively coupled plasma mass spectrometry (ICP-MS). Four sample pre-concentration techniques, including calcium phosphate, iron hydroxide and manganese dioxide co-precipitation and evaporation were compared and the applicability of different techniques was discussed in order to evaluate and establish the optimal method for in vivo radioassay program. The analytical results indicate that the various sample pre-concentration approaches afford dissimilar method performances and care should be taken for specific experimental parameters for improving chemical yields. The best analytical performances in terms of turnaround time (6 h) and chemical yields for plutonium (88.7 +/- 11.6%) and neptunium (94.2 +/- 2.0%) were achieved by manganese dioxide co-precipitation. The need of drying ashing (>= 7 h) for calcium phosphate co-precipitation and long-term aging (5 d) for iron hydroxide co-precipitation, respectively, rendered time-consuming analytical protocols. Despite the fact that evaporation is also somewhat time-consuming (1.5 d), it endows urinalysis methods with better reliability and repeatability compared with co-precipitation techniques. In view of the applicability of different pre-concentration techniques proposed previously in the literature, the main challenge behind relevant method development is pointed to be the release of plutonium and neptunium associated with organic compounds in real urine assays. In this work, different protocols for decomposing organic matter in urine were investigated, of which potassium persulfate (K2S2O8) treatment provided the highest chemical yield of neptunium in the iron hydroxide co-precipitation step, yet, the occurrence of sulfur compounds in the processed sample deteriorated the analytical performance of the ensuing extraction chromatographic separation with chemical yields of <= 50%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 37 条
  • [1] Purification and separation of 239+240Pu and 241Am in biological samples by anion-exchange and extraction chromatography for high resolution alpha-spectrometry analyses
    Arginelli, D.
    Berton, G.
    Bortoluzzi, S.
    Canuto, G.
    Groppi, F.
    Montalto, M.
    Nocente, M.
    Ridone, S.
    Vegro, M.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 277 (01) : 65 - 71
  • [2] Becker JS, 2004, ATOM SPECTROSC, V25, P197
  • [3] Urine radiobioassay intercomparison results from the intercomparison studies program at oak ridge national laboratory
    Bores, N. E.
    Schultz, M. K.
    Rankin, J. M.
    Denton, A. J.
    Payne, G. F.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 277 (01) : 111 - 116
  • [4] The use of calix[6]arene molecules for actinides analysis in urine and drinking water: an alternative to current procedures
    Bouvier-Capely, C.
    Manoury, A.
    Legrand, A.
    Bonthonneau, J. P.
    Cuenot, F.
    Rebiere, F.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (02) : 611 - 615
  • [5] Ultra-trace determination of plutonium in urine samples using a compact accelerator mass spectrometry system operating at 300 kV
    Dai, Xiongxin
    Christl, Marcus
    Kramer-Tremblay, Sheila
    Synal, Hans-Arno
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (01) : 126 - 130
  • [6] Isotopic uranium analysis in urine samples by alpha spectrometry
    Dai, Xiongxin
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 289 (02) : 595 - 600
  • [7] AN EMERGENCY BIOASSAY METHOD FOR ACTINIDES IN URINE
    Dai, Xiongxin
    Kramer-Tremblay, Sheila
    [J]. HEALTH PHYSICS, 2011, 101 (02): : 144 - 147
  • [8] Elias G., 1997, RADIOACT RADIOCHEM, V8, P20
  • [9] Determination of femtogram quantities of 239Pu and 240Pu in bioassay samples by thermal ionization mass spectrometry
    Elliot, NL
    Bickel, GA
    Linauskas, SH
    Paterson, LM
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 267 (03) : 637 - 650
  • [10] Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry
    Epov, VN
    Benkhedda, K
    Cornett, RJ
    Evans, RD
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (05) : 424 - 430