MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

被引:26
作者
Maijers, M. C. [1 ]
Niessen, F. B. [1 ,2 ]
Veldhuizen, J. F. H. [3 ]
Ritt, M. J. P. F. [1 ]
Manoliu, R. A. [3 ,4 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Plast Reconstruct & Hand Surg, NL-1007 MB Amsterdam, Netherlands
[2] Jan van Goyen Clin, Dept Plast Surg, Amsterdam, Netherlands
[3] MRI Ctr, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam Med Ctr, Dept Radiol, NL-1007 MB Amsterdam, Netherlands
关键词
Magnetic resonance imaging (MRI); Silicone breast implants; Accuracy; Interobserver variability; Intraobserver variability; MAGNETIC-RESONANCE; DATA SYSTEM; RELATIVE EFFICACIES; EUROPEAN MARKET; DIAGNOSIS; MAMMOGRAPHY; PIP; PREVALENCE;
D O I
10.1007/s00330-014-3119-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The recall of Poly Implant ProthSse (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. aEuro cent MRI has a high accuracy in diagnosing rupture in silicone breast implants. aEuro cent MRI appears to be a consistent diagnostic test with excellent interobserver agreement. aEuro cent A simple, uniform classification system, improves communication between radiologist and plastic surgeon. aEuro cent The interobserver agreement on implant rupture is higher than on extracapsular leakage.
引用
收藏
页码:1167 / 1175
页数:9
相关论文
共 37 条
[1]  
Administration USFaD, 2011, MED DEV SIL GEL FILL
[2]   COMPARATIVE SILICONE BREAST IMPLANT EVALUATION USING MAMMOGRAPHY, SONOGRAPHY, AND MAGNETIC-RESONANCE-IMAGING - EXPERIENCE WITH 59 IMPLANTS [J].
AHN, CY ;
DEBRUHL, ND ;
GORCZYCA, DP ;
SHAW, WW ;
BASSETT, LW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 94 (05) :620-627
[3]   DEFINITIVE DIAGNOSIS OF BREAST IMPLANT RUPTURE USING MAGNETIC-RESONANCE-IMAGING [J].
AHN, CY ;
SHAW, WW ;
NARAYANAN, K ;
GORCZYCA, DP ;
SINHA, S ;
DEBRUHL, ND ;
BASSETT, LW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 92 (04) :681-691
[4]   Assessing Strength of Evidence in Diagnostic Tests [J].
Aliu, Oluseyi ;
Chung, Kevin C. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 129 (06) :989-998
[5]   Breast imaging reporting and data system standardized mammography lexicon: Observer variability in lesion description [J].
Baker, JA ;
Kornguth, PJ ;
Floyd, CE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :773-778
[6]   Imaging signs and radiologists' jargon of ruptured breast implants [J].
Beekman, WH ;
van Straalen, WR ;
Hage, JJ ;
van Amerongen, AHMT ;
Mulder, JW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 102 (04) :1281-1289
[7]   MR imaging of extracapsular silicone from breast implants: Diagnostic pitfalls [J].
Berg, WA ;
Nguyen, TK ;
Middleton, MS ;
Soo, MS ;
Pennello, G ;
Brown, SL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (02) :465-472
[8]   Breast imaging reporting and data system: Inter- and intraobserver variability in feature analysis and final assessment [J].
Berg, WA ;
Campassi, C ;
Langenberg, P ;
Sexton, MJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (06) :1769-1777
[9]   Prevalence of rupture of silicone gel breast implants revealed on MR imaging in a population of women in Birmingham, Alabama [J].
Brown, SL ;
Middleton, MS ;
Berg, WA ;
Soo, MS ;
Pennello, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) :1057-1064
[10]   MRI for detecting silicone breast implant rupture: Meta-analysis and implications [J].
Cher, DJ ;
Conwell, JA ;
Mandell, JS .
ANNALS OF PLASTIC SURGERY, 2001, 47 (04) :367-380