Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging

被引:46
作者
Savini, Giacomo [1 ]
Taroni, Leonardo [2 ]
Schiano-Lomoriello, Domenico [1 ]
Hoffer, Kenneth J. [3 ,4 ]
机构
[1] IRCCS GB, Bietti Fdn, Rome, Italy
[2] Univ Bologna, S Orsola Malpighi Univ Hosp, Bologna, Italy
[3] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[4] St Marys Eye Ctr, Santa Monica, CA USA
关键词
LENS POWER CALCULATION; OPTICAL COHERENCE TOMOGRAPHY; PREDICTION ACCURACY; REPRODUCIBILITY; BIOMETER; TOPOGRAPHY; AGREEMENT; POSTERIOR; CAMERA; CURVATURE;
D O I
10.1038/s41433-020-01245-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives We aimed (1) to assess the repeatability of Total Keratometry (TK) and standard keratometry (K) measurements, as provided by the IOLMaster 700 (Carl Zeiss Meditec), and (2) to compare the corneal astigmatism measured by TK to the total corneal astigmatism (TCA) measured by a Scheimpflug camera (Pentacam AXL, Oculus). Methods Two groups of patients were prospectively enrolled: Group A included previously unoperated eyes undergoing cataract surgery, and Group B eyes with previous myopic corneal excimer laser surgery. TK and K were measured three times by the same examiner. Repeatability was assessed based on the within-subject standard deviation (S-w), test-retest variability, coefficient of variation and intraclass correlation coefficient (ICC). In Group A, TCA was measured once and compared to TK astigmatism. Vector analysis was performed according to N AE ser. Results In Group A (69 eyes) the mean K and TK were, respectively, 43.14 +/- 1.37 D and 43.18 +/- 1.37 D. In Group B (51 eyes) the mean K and TK were, respectively, 40.14 +/- 2.20 D and 39.71 +/- 2.35 D. The repeatability of the average K and TK was high (S-w < 0.10D). All measurements revealed an ICC > 0.9. For most measurements the variance of K and TK did not show any statistically significant difference either within groups or between groups. Vectors KP(45) were significantly different between TK astigmatism and TCA. Conclusions TK measurements offer high repeatability in unoperated and post-excimer laser surgery eyes. TK astigmatism and TCA measurements could not be considered interchangeable.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 40 条
[1]  
[Anonymous], 1994, ACC TRUEN PREC MEA 1
[2]   Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement [J].
Aramberri, Jaime ;
Araiz, Luis ;
Garcia, Ane ;
Illarramendi, Igor ;
Olmos, Jaione ;
Oyanarte, Izaskun ;
Romay, Amaya ;
Vigara, Itxaso .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (11) :1934-1949
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[5]  
Dupont WD, 2009, PS POWER SAMPLE SIZE
[6]   Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas [J].
Fabian, Ekkehard ;
Wehner, Wolfram .
JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (06) :362-369
[7]   Origins of the Keratometer and its Evolving Role in Ophthalmology [J].
Gutmark, Ron ;
Guyton, David L. .
SURVEY OF OPHTHALMOLOGY, 2010, 55 (05) :481-497
[8]   Intraocular lens power calculation after previous laser refractive surgery [J].
Hoffer, Kenneth J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :759-765
[9]   Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMaster [J].
Huang, Jinhai ;
Savini, Giacomo ;
Hoffer, Kenneth J. ;
Chen, Hao ;
Lu, Weicong ;
Hu, Qingjie ;
Bao, Fangjun ;
Wang, Qinmei .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) :493-498
[10]   Repeatability and reproducibility of ocular biometry using a new noncontact optical low-coherence interferometer [J].
Huang, Jinhai ;
Savini, Giacomo ;
Wu, Fan ;
Yu, Xinxin ;
Yang, Jing ;
Yu, Ayong ;
Yu, Ye ;
Wang, Qinmei .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10) :2233-2241