Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes

被引:2
作者
Lee, Hun [1 ]
Lee, Kwanghyun [1 ]
Ahn, Ji Min [1 ]
Kim, Eung Kweon [1 ,2 ]
Sgrignoli, Bradford [1 ]
Kim, Tae-im [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul 120752, South Korea
[2] Yonsei Univ, Brain Korea Project Med Sci 21, Corneal Dystrophy Res Inst, Dept Ophthalmol,Severance Biomed Sci Inst,Coll Me, Seoul 120752, South Korea
关键词
Double-pass system; ray-tracing aberrometer; optical quality; multifocal intraocular lens; cataract; surgery; RETINAL-IMAGE QUALITY; SPHERICAL-ABERRATION; PERFORMANCE; VISION; DECENTRATION; TILT;
D O I
10.3349/YMJ.2014.55.5.1413
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We investigated the correlations between optical quality parameters obtained from the double-pass sytem and ocular aberrations obtained from the raytracing aberrometer in multifocal intraocular lens (TOL) implanted eyes. Materials and Methods: Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter index, and objective pseudo-accommodation obtained from the double-pass system were compared with root mean square (RMS) total aberration, RMS higher-order aberration, and spherical aberration obtained from the ray-tracing aberrometer. Additionally, parameters of the double-pass system and ray-tracing aberrometer were compared with manifested refraction values and subjective visual acuity, respectively. Results: There was no statistically significant correlation between optical quality parameters obtained from the double-pass system and ocular aberrations, except between the Strehl ratio and RMS total aberration (r=-0.566, p=0.018). No significant correlations were found between the parameters of both devices, and manifested refraction values or subjective visual acuity. Conclusion: Optical quality parameters, especially the Strehl ratio, in multifocal IOL implanted eyes were affected by RMS total aberration. Further studies based on accurate measurements of ocular aberrations and additional optical quality parameters are needed to delineate relationships between optical quality parameters and ocular aberrations in multifocal IOL implanted eyes.
引用
收藏
页码:1413 / 1420
页数:8
相关论文
共 35 条
  • [1] Age-related changes in accommodation measured with a double-pass system
    Aldaba, Mikel
    Vilaseca, Meritxell
    Arjona, Montserrat
    Pujol, Jaume
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (04) : 508 - 515
  • [2] Visual function comparison of 2 aspheric multifocal intraocular lenses
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Blazquez, Jose I.
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02) : 242 - 248
  • [3] Visual and Optical Performance With Two Different Diffractive Multifocal Intraocular Lenses Compared to a Monofocal Lens
    Alio, Jorge L.
    Pinero, David P.
    Plaza-Puche, Ana B.
    Amparo, Francisco
    Jimenez, Ramon
    Rodriguez-Prats, Jose L.
    Javaloy, Jaime
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (08) : 570 - 581
  • [4] Applegate RA, 2002, J REFRACT SURG, V18, pS556
  • [5] DOUBLE-PASS MEASUREMENTS OF THE RETINAL-IMAGE QUALITY WITH UNEQUAL ENTRANCE AND EXIT PUPIL SIZES AND THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM
    ARTAL, P
    IGLESIAS, I
    LOPEZGIL, N
    GREEN, DG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (10): : 2358 - 2366
  • [6] An Objective Scatter Index Based on Double-Pass Retinal Images of a Point Source to Classify Cataracts
    Artal, Pablo
    Benito, Antonio
    Perez, Guillermo M.
    Alcon, Encarna
    De Casas, Alvaro
    Pujol, Jaume
    Marin, Jose M.
    [J]. PLOS ONE, 2011, 6 (02):
  • [7] Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes
    Benito, Antonio
    Perez, Guillermo M.
    Mirabet, Sandra
    Vilaseca, Meritxell
    Pujol, Jaume
    Marin, Jose M.
    Artal, Pablo
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08) : 1481 - 1487
  • [8] Problems in the measurement of wavefront aberration for eyes implanted with diffractive bifocal and multifocal intralocular lenses
    Charman, W. Neil
    Montes-Mico, Robert
    Radhakrishnan, Hema
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) : 280 - 286
  • [9] Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging - Validation study
    de Castro, Alberto
    Rosales, Patricia
    Marcos, Susana
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) : 418 - 429
  • [10] Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument
    Díaz-Doutón, F
    Benito, A
    Pujol, J
    Arjona, M
    Güell, JL
    Artal, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (04) : 1710 - 1716