A Systematic Review of Air Quality Sensors, Guidelines, and Measurement Studies for Indoor Air Quality Management

被引:62
作者
Zhang, He [1 ]
Srinivasan, Ravi [1 ]
机构
[1] Univ Florida, UrbSys Urban Bldg Energy Sensing Controls Big Dat, ME Rinker Sr Sch Construct Management, Gainesville, FL 32603 USA
关键词
indoor air quality; standards; guidelines; pollutants; sick building syndrome; low-cost sensor; SICK BUILDING SYNDROME; VOLATILE ORGANIC-COMPOUNDS; URBAN NURSERY SCHOOLS; LOW-COST SENSORS; PARTICULATE MATTER; SULFUR-DIOXIDE; POLLUTANT CONCENTRATIONS; ENVIRONMENTAL-QUALITY; ELEMENTAL COMPOSITION; SOURCE APPORTIONMENT;
D O I
10.3390/su12219045
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The existence of indoor air pollutants-such as ozone, carbon monoxide, carbon dioxide, sulfur dioxide, nitrogen dioxide, particulate matter, and total volatile organic compounds-is evidently a critical issue for human health. Over the past decade, various international agencies have continually refined and updated the quantitative air quality guidelines and standards in order to meet the requirements for indoor air quality management. This paper first provides a systematic review of the existing air quality guidelines and standards implemented by different agencies, which include the Ambient Air Quality Standards (NAAQS); the World Health Organization (WHO); the Occupational Safety and Health Administration (OSHA); the American Conference of Governmental Industrial Hygienists (ACGIH); the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE); the National Institute for Occupational Safety and Health (NIOSH); and the California ambient air quality standards (CAAQS). It then adds to this by providing a state-of-art review of the existing low-cost air quality sensor (LCAQS) technologies, and analyzes the corresponding specifications, such as the typical detection range, measurement tolerance or repeatability, data resolution, response time, supply current, and market price. Finally, it briefly reviews a sequence (array) of field measurement studies, which focuses on the technical measurement characteristics and their data analysis approaches.
引用
收藏
页码:1 / 40
页数:38
相关论文
共 227 条
  • [1] A review of standards and guidelines set by international bodies for the parameters of indoor air quality
    Abdul-Wahab, Sabah Ahmed
    En, Stephen Chin Fah
    Elkamel, Ali
    Ahmadi, Lena
    Yetilmezsoy, Kaan
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2015, 6 (05) : 751 - 767
  • [2] Indoor Endotoxin Exposure and Ambient Air Pollutants Interact on Asthma Outcomes
    Abramson, Michael J.
    Guo, Yuming
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 200 (06) : 652 - 654
  • [3] ACGIH, 2020, TLV CHEM SUBST INTR
  • [4] ACGIH, 2019, AM C GOV IND HYG ACH
  • [5] Using Low-Cost Air Quality Sensor Networks to Improve the Spatial and Temporal Resolution of Concentration Maps
    Ahangar, Faraz Enayati
    Freedman, Frank R.
    Venkatram, Akula
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (07)
  • [6] Alphasense Ltd, COB4 CARB MON CO B4
  • [7] Architectural evaluation of thermal comfort: Sick building syndrome symptoms in engineering education laboratories
    Amin, Nor Dina Md
    Akasah, Zainal Abidin
    Razzaly, Wahid
    [J]. 4TH WORLD CONGRESS ON TECHNICAL VOCATIONAL EDUCATION AND TRAINING (4THWOCTVET), 2015, 204 : 19 - 28
  • [8] TVOC and health in non-industrial indoor environments - Report from a Nordic scientific consensus meeting at Langholmen in Stockholm, 1996
    Andersson, K
    Bakke, JV
    Bjorseth, O
    Bornehag, CG
    Clausen, G
    Hongslo, JK
    Kjellman, M
    Kjaergaard, S
    Levy, F
    Molhave, L
    Skerfving, S
    Sundell, J
    [J]. INDOOR AIR, 1997, 7 (02) : 78 - 91
  • [9] [Anonymous], 2016, TIDA00378
  • [10] [Anonymous], 2019, AIR QUAL CIT COUNT