Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study

被引:9
作者
Roleder, Tomasz [1 ]
Kedhi, Elvin [2 ]
Berta, Balazs [2 ]
Gasior, Pawel [1 ]
Wanha, Wojciech [1 ]
Roleder, Magda [1 ]
Fluder, Joanna [1 ]
Smolka, Grzegorz [1 ]
Ochala, Andrzej [1 ]
Wojakowski, Wojciech [1 ]
机构
[1] Med Univ Silesia, Dept Cardiol & Struct Heart Dis, Div Cardiol 3, Katowice, Poland
[2] Isala Haartctr, Zwolle, Netherlands
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2019年 / 15卷 / 02期
关键词
zotarolimus-eluting stent; vessel healing; optical coherence tomography; 1-month follow-up; BARE-METAL STENTS; CLINICAL-OUTCOMES; NEOINTIMAL COVERAGE; IMPLANTATION; IMPACT; OCT; METAANALYSIS; GENERATION; THERAPY; 3-MONTH;
D O I
10.5114/aic.2019.86009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: To date the early strut coverage with the second-generation durable-polymer ONYX zotarolimus-eluting stent (O-ZES) is unknown. Aim: Optical coherence tomography (OCT) assessed the strut coverage of O-ZES at thirty-day follow-up. Material and methods: OCT was performed after implantation and at 1-month follow-up in 15 patients treated with O-ZES. Results: Mean patient age was 67 +/- 7 years (73% males). The clinical presentation consisted of acute coronary syndromes (n = 13) and stable coronary disease (n = 2). Four (26%) patients had diabetes. OCT analysis was performed at baseline and 1-month follow-up in all stents. 378 cross-sections with 3582 struts were assessed at baseline and 3661 at follow-up. At follow-up, 88% struts were covered by tissue with a median thickness 37.91 mu m (IQR: 22.32-64.15). Median in-stent area obstruction by neointima was 2.64% (IQR: 1.70-4.84). From the total stent covered area, 92.3% showed complete strut coverage. Homogeneous tissue was observed in 74% of cases. There were no differences in minimal lumen area (5.07 +/- 1.08 mm(2) vs. 4.81 +/- 0.94 mm(2), p = 0.125) or minimal stent area (4.95 +/- 1.22 mm(2) vs. 4.92 +/- 0.99 mm(2)) at baseline and at follow-up. There were no differences in the rate of strut malapposition (4.3% vs. 5.7%, p = 0.417). For all stents, malapposition volume was 47.9 mm(3) at baseline and 51.7 mm(3) at follow-up, giving the late acquired stent malapposition volume of 3.8 mm(3). Conclusions: The second-generation durable polymer O-ZES showed favorable vessel healing at 30-day OCT follow-up.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 29 条
  • [1] Vascular responses to drug eluting stents - Importance of delayed healing
    Finn, Aloke V.
    Nakazawa, Gaku
    Joner, Michael
    Kolodgie, Frank D.
    Mont, Erik K.
    Gold, Herman K.
    Virmani, Renu
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2007, 27 (07) : 1500 - 1510
  • [2] Comparison of the 9-month intra-stent conditions and 2-year clinical outcomes after Resolute zotarolimus-eluting stent implantation between 3-month and standard dual antiplatelet therapy
    Fujimoto, Wataru
    Sawada, Takahiro
    Toba, Takayoshi
    Takahashi, Yu
    Miyata, Taishi
    Oishi, Shogo
    Osue, Tsuyoshi
    Onishi, Tetsuari
    Takaya, Tomofumi
    Shimane, Akira
    Taniguchi, Yasuyo
    Kawai, Hiroya
    Yasaka, Yoshinori
    [J]. JOURNAL OF CARDIOLOGY, 2018, 72 (1-2) : 66 - 73
  • [3] Head-to-Head Comparison of the Neointimal Response Between Metallic and Bioresorbable Everolimus-Eluting Scaffolds Using Optical Coherence Tomography
    Gomez-Lara, Josep
    Brugaletta, Salvatore
    Farooq, Vasim
    Onuma, Yoshinobu
    Diletti, Roberto
    Windecker, Stephan
    Thuesen, Leif
    McClean, Dougal
    Koolen, Jacques
    Whitbourn, Robert
    Dudek, Dariusz
    Smits, Pieter C.
    Chevalier, Bernard
    Regar, Evelyn
    Veldhof, Susan
    Rapoza, Richard
    Ormiston, John A.
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (12) : 1271 - 1280
  • [4] Serial Analysis of the Malapposed and Uncovered Struts of the New Generation of Everolimus-Eluting Bioresorbable Scaffold With Optical Coherence Tomography
    Gomez-Lara, Josep
    Radu, Maria
    Brugaletta, Salvatore
    Farooq, Vasim
    Diletti, Roberto
    Onuma, Yoshinobu
    Windecker, Stephan
    Thuesen, Leif
    McClean, Dougal
    Koolen, Jacques
    Whitbourn, Robert
    Dudek, Dariusz
    Smits, Pieter C.
    Regar, Evelyn
    Veldhof, Susan
    Rapoza, Richard
    Ormiston, John A.
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (09) : 992 - 1001
  • [5] Neointimal coverage of zotarolimus-eluting stent at 1, 2, and 3 months' follow-up: an optical coherence tomography study
    Hashikata, Takehiro
    Tojo, Taiki
    Namba, Sayaka
    Kitasato, Lisa
    Hashimoto, Takuya
    Kameda, Ryo
    Shimohama, Takao
    Yamaoka-Tojo, Minako
    Ako, Junya
    [J]. HEART AND VESSELS, 2016, 31 (02) : 206 - 211
  • [6] Impact of polymer hydrophilicity on biocompatibility: Implication for DES polymer design
    Hezi-Yamit, Ayala
    Sullivan, Carol
    Wong, Jennifer
    David, Laura
    Chen, Mingfei
    Cheng, Peiwen
    Shumaker, David
    Wilcox, Josiah N.
    Udipi, Kishore
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 90A (01) : 133 - 141
  • [7] Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation
    Izumi, Daisuke
    Miyahara, Masatoshi
    Fujimoto, Naoki
    Fukuoka, Shusuke
    Sakai, Masataka
    Dohi, Kaoru
    Ito, Masaaki
    [J]. HEART AND VESSELS, 2016, 31 (08) : 1247 - 1256
  • [8] An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis
    Jaguszewski, Milosz
    Aloysius, Romila
    Wang, Wei
    Bezerra, Hiram G.
    Hill, Jonathan
    de Winter, Robbert J.
    Karjalainen, Pasi P.
    Verheye, Stefan
    Wijns, William
    Luescher, Thomas F.
    Joner, Michael
    Costa, Marco
    Landmesser, Ulf
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (05) : 489 - 499
  • [9] Long-Term Outcomes of Neointimal Hyperplasia Without Neoatherosclerosis After Drug-Eluting Stent Implantation
    Kim, Jung-Sun
    Lee, Jung-Hee
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. JACC-CARDIOVASCULAR IMAGING, 2014, 7 (08) : 788 - 795
  • [10] Neointimal patterns obtained by optical coherence tomography correlate with specific histological components and neointimal proliferation in a swine model of restenosis
    Kim, Jung-Sun
    Afari, Maxwell E.
    Ha, Jinyong
    Tellez, Armando
    Milewski, Krzysztof
    Conditt, Gerard
    Cheng, Yanping
    Yi, Geng Hua
    Kaluza, Greg L.
    Granada, Juan F.
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (03) : 292 - 298