Lumbar Fusion Leads to Increases in Angular Motion and Stress Across Sacroiliac Joint A Finite Element Study

被引:143
作者
Ivanov, Alexander A. [1 ]
Kiapour, Ali [1 ]
Ebraheim, Nabil A. [1 ]
Goel, Vijay [1 ]
机构
[1] Univ Toledo, Dept Orthopaed Surg & Bioengn, E CORE, Coll Med & Engn, Toledo, OH 43614 USA
关键词
lumbar spine fusion procedures; finite element investigation; low back pain syndrome; INTERBODY FUSION; SPINAL-FUSION; PELVIC BONE; ADJACENT; SEGMENTS; DISC; SPONDYLOLYSIS; BIOMECHANICS; PEDICLE; BACK;
D O I
10.1097/BRS.0b013e3181978ea3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. The assessment of sacrum angular motions and stress across sacroiliac joint (SIJ) articular surfaces using finite element lumbar spine-pelvis model and simulated posterior fusion surgical procedures. Objective. To quantify the increase in sacrum angular motions and stress across SIJ as a function of fused lumbar spine using finite element lumbar spine-pelvis model. Summary of Background Data. A review of the literature suggests that for 20% to 30% of spine surgery patients, failed back surgery syndrome as a possible complication. The SIJ might be a contributing factor in failed back surgery syndrome in 29% to 40% of cases. The exact pathomechanism which leads to SIJ pain generation is not well understood. We hypothesized that lumbar spine fusion leads to increased motion or stresses at the SIJ; this alone could be a trigger of the pain syndrome. Methods. A finite element model of the lumbar spine-pelvis was used to simulate the posterior fusion at L4-L5, L4-S1, and L5-S1 levels. The magnitude of the sacrum angular motion and average of stresses across SIJ articular surfaces were compared with intact model in flexion, extension, lateral bending, and axial rotation motions. Results. The computed sacrum angular motions in intact spine, after L4-L5, L5-S1, and L4-S1 fusion gradually increased with maximum value in L4-S1 fusion model. Also, the average stress on SIJ articular surfaces progressively increased from minimum in L4-L5 to maximum in L4-S1 fusion models. Conclusion. The fusion at the lumbar spine level increased motion and stresses at the SIJ. This could be a probable reason for low back pain in patients after lumbar spine fusion procedures.
引用
收藏
页码:E162 / E169
页数:8
相关论文
共 53 条
[1]  
[Anonymous], PAIN MED, DOI DOI 10.1046/J.1526-4637.2002.02033.X
[2]   THE AXIAL SACROILIAC JOINT [J].
BAKLAND, O ;
HANSEN, JH .
ANATOMIA CLINICA, 1984, 6 (01) :29-36
[3]   Evaluation of the mobility of adjacent segments after posterior thoracolumbar fixation: a biomechanical study [J].
Bastian, L ;
Lange, U ;
Knop, C ;
Tusch, G ;
Blauth, M .
EUROPEAN SPINE JOURNAL, 2001, 10 (04) :295-300
[4]   LOCATION-DEPENDENT VARIATIONS IN THE MATERIAL PROPERTIES OF THE ANTERIOR CRUCIATE LIGAMENT [J].
BUTLER, DL ;
GUAN, YN ;
KAY, MD ;
CUMMINGS, JF ;
FEDER, SM ;
LEVY, MS .
JOURNAL OF BIOMECHANICS, 1992, 25 (05) :511-518
[5]   A biomechanical comparison of posterolateral fusion and posterior fusion in the lumbar spine [J].
Chen, CS ;
Cheng, CK ;
Liu, CL ;
Simmons, ED .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (01) :53-63
[6]  
Chen CS, 2001, MED ENG PHYS, V23, P483
[7]   Effects of short anterior lumbar interbody fusion on biomechanics of neighboring unfused segments [J].
Chow, DHK ;
Luk, KDK ;
Evans, JH ;
Leong, JCY .
SPINE, 1996, 21 (05) :549-555
[8]   DEVELOPMENT AND VALIDATION OF A 3-DIMENSIONAL FINITE-ELEMENT MODEL OF THE PELVIC BONE [J].
DALSTRA, M ;
HUISKES, R ;
VANERNING, L .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03) :272-278
[9]   LOAD-TRANSFER ACROSS THE PELVIC BONE [J].
DALSTRA, M ;
HUISKES, R .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :715-724
[10]   COMPARISON OF IN-VIVO AND IN-VITRO ADJACENT SEGMENT MOTION AFTER LUMBAR FUSION [J].
DEKUTOSKI, MB ;
SCHENDEL, MJ ;
OGILVIE, JW ;
OLSEWSKI, JM ;
WALLACE, LJ ;
LEWIS, JL .
SPINE, 1994, 19 (15) :1745-1751