Spectrophotometric and visual evaluation of peri-implant soft tissue color

被引:31
|
作者
Benic, Goran I. [1 ]
Scherrer, Daniela
Sancho-Puchades, Manuel [1 ]
Thoma, Daniel S. [1 ]
Hammerle, Christoph H. F. [1 ]
机构
[1] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent Med, Plattenstr 11, CH-8032 Zurich, Switzerland
关键词
color; dental; gingiva; implant; mucosa; peri-implant; soft tissue; spectrophotometry; spectrophotometer; thickness; CONTROLLED CLINICAL-TRIAL; BEAM COMPUTED-TOMOGRAPHY; RESTORATIVE MATERIALS; CONSENSUS STATEMENTS; OPTICAL PHENOMENON; DENTAL IMPLANTS; BUCCAL BONE; AESTHETICS; ZIRCONIA; GINGIVA;
D O I
10.1111/clr.12781
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo spectrophotometrically and visually test whether the peri-implant mucosal color differs from the color of the natural gingiva. Material and methodsForty single implants in the incisor and premolar region of 40 patients were assessed 3-7years after implant placement. The differences of the color components lightness, chroma along red-green axis, chroma along yellow-blue axis, and the total color difference E between peri-implant mucosa and natural gingiva were measured with a spectrophotometer. The color difference between peri-implant mucosa and natural gingiva was visually evaluated by clinicians and rated as clinically visible or clinically invisible from speaking distance. The dimensions of peri-implant mucosa and gingiva at the mid-buccal aspect were evaluated by using cone-beam CT. Spearman analysis was performed to detect correlations between different variables. Two-sided t-test, ANOVA, Mann-Whitney, and Kruskal-Wallis tests were applied to detect differences between the groups. ResultsThe spectrophotometrically assessed color difference Delta E between peri-implant mucosa and natural gingiva amounted to 7.0 +/- 3.9. The peri-implant mucosa presented a significant dark, greenish and bluish discoloration in comparison with gingiva at control teeth. Clinical investigation revealed that in 60% of sites the color difference between peri-implant mucosa and natural gingiva was clinically visible from speaking distance. The threshold value Delta E for the extraoral clinical distinction of mucosal color differences measured 7.5. When comparing the groups with visible and invisible color differences with respect to the three color components, a significant difference was found only for chroma along yellow-blue axis. In the group with visible color difference, mucosa presented a bluish discoloration. Correlation analysis indicated that with an increase in mucosal thickness, a trend for smaller Delta E was found. ConclusionThe spectrophotometrically assessed color of the peri-implant mucosa revealed more dark, green and blue components compared to the natural gingiva. At 60% of the implants, peri-implant mucosal discoloration was visible from speaking distance. The sites with visible and those with invisible mucosal discolorations differed significantly only regarding the chroma along yellow-blue axis.
引用
收藏
页码:192 / 200
页数:9
相关论文
共 50 条
  • [41] Influences of standardized clinical probing on peri-implant soft tissue seal in a situation of peri-implant mucositis: A histomorphometric study in dogs
    Cai, Rong
    Liu, Yi
    Wang, Xinge
    Wei, Hongbo
    Wang, Jin
    Cao, Yanze
    Lei, Jiaqi
    Li, Dehua
    JOURNAL OF PERIODONTOLOGY, 2024, 95 (03) : 233 - 243
  • [42] The peri-implant mucosa color: A systematic appraisal of methods for its assessment and clinical significance
    Mancini, Leonardo
    Barootchi, Shayan
    Thoma, Daniel S.
    Jung, Ronald E.
    Gallucci, German O.
    Wang, Hom-Lay
    Tavelli, Lorenzo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (02) : 224 - 240
  • [43] Healing of Peri-Implant Tissue following Flapless Implant Surgery
    Bagde, Hiroj
    Pawar, Sangeeta K.
    Hotchandani, Kamal
    Malik, Nida
    Awasthi, Vijaya
    Patil, Mohit V.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1139 - S1141
  • [44] Digital evaluation of facial peri-implant mucosal thickness and its impact on dental implant aesthetics
    Amr Khorshed
    Javi Vilarrasa
    Alberto Monje
    Jose Nart
    Gonzalo Blasi
    Clinical Oral Investigations, 2023, 27 : 581 - 590
  • [45] THE INFLUENCE OF THE MASTICATORY MUCOSA ON THE PERI-IMPLANT SOFT-TISSUE CONDITION
    WENNSTROM, JL
    BENGAZI, F
    LEKHOLM, U
    CLINICAL ORAL IMPLANTS RESEARCH, 1994, 5 (01) : 1 - 8
  • [46] Peri-implant soft tissue stability through vestibular extension procedure: a retrospective study
    Bawankar, Pranjali, V
    Kolte, Abhay P.
    Kolte, Rajashri A.
    QUINTESSENCE INTERNATIONAL, 2022, 53 (03): : 226 - 235
  • [47] Influence of immediate implant loading on peri-implant soft tissue morphology in the edentulous maxilla
    Gallucci, German O.
    Mavropoulos, Anestis
    Bernard, Jean-Pierre
    Belser, Urs C.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (04) : 595 - 602
  • [48] A Clinical Study Assessing the Influence of Anodized Titanium and Zirconium Dioxide Abutments and Peri-implant Soft Tissue Thickness on the Optical Outcome of Implant-Supported Lithium Disilicate Single Crowns
    Martinez-Rus, Francisco
    Prieto, Marta
    Salido, Maria P.
    Madrigal, Cristina
    Ozcan, Mutlu
    Pradies, Guillermo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 156 - 163
  • [49] Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis
    Gehrke, Peter
    Pietruska, Maria Julia
    Ladewig, Johannes
    Fischer, Carsten
    Sader, Robert
    Weigl, Paul
    JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (04) : 231 - 243
  • [50] Use of a xenogenic collagen membrane in peri-implant soft tissue augmentation
    Papi, Piero
    Di Murro, Bianca
    Pompa, Giorgio
    DENTAL CADMOS, 2019, 87 (03) : 150 - 157