Spectrophotometric and visual evaluation of peri-implant soft tissue color

被引:31
|
作者
Benic, Goran I. [1 ]
Scherrer, Daniela
Sancho-Puchades, Manuel [1 ]
Thoma, Daniel S. [1 ]
Hammerle, Christoph H. F. [1 ]
机构
[1] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent Med, Plattenstr 11, CH-8032 Zurich, Switzerland
关键词
color; dental; gingiva; implant; mucosa; peri-implant; soft tissue; spectrophotometry; spectrophotometer; thickness; CONTROLLED CLINICAL-TRIAL; BEAM COMPUTED-TOMOGRAPHY; RESTORATIVE MATERIALS; CONSENSUS STATEMENTS; OPTICAL PHENOMENON; DENTAL IMPLANTS; BUCCAL BONE; AESTHETICS; ZIRCONIA; GINGIVA;
D O I
10.1111/clr.12781
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo spectrophotometrically and visually test whether the peri-implant mucosal color differs from the color of the natural gingiva. Material and methodsForty single implants in the incisor and premolar region of 40 patients were assessed 3-7years after implant placement. The differences of the color components lightness, chroma along red-green axis, chroma along yellow-blue axis, and the total color difference E between peri-implant mucosa and natural gingiva were measured with a spectrophotometer. The color difference between peri-implant mucosa and natural gingiva was visually evaluated by clinicians and rated as clinically visible or clinically invisible from speaking distance. The dimensions of peri-implant mucosa and gingiva at the mid-buccal aspect were evaluated by using cone-beam CT. Spearman analysis was performed to detect correlations between different variables. Two-sided t-test, ANOVA, Mann-Whitney, and Kruskal-Wallis tests were applied to detect differences between the groups. ResultsThe spectrophotometrically assessed color difference Delta E between peri-implant mucosa and natural gingiva amounted to 7.0 +/- 3.9. The peri-implant mucosa presented a significant dark, greenish and bluish discoloration in comparison with gingiva at control teeth. Clinical investigation revealed that in 60% of sites the color difference between peri-implant mucosa and natural gingiva was clinically visible from speaking distance. The threshold value Delta E for the extraoral clinical distinction of mucosal color differences measured 7.5. When comparing the groups with visible and invisible color differences with respect to the three color components, a significant difference was found only for chroma along yellow-blue axis. In the group with visible color difference, mucosa presented a bluish discoloration. Correlation analysis indicated that with an increase in mucosal thickness, a trend for smaller Delta E was found. ConclusionThe spectrophotometrically assessed color of the peri-implant mucosa revealed more dark, green and blue components compared to the natural gingiva. At 60% of the implants, peri-implant mucosal discoloration was visible from speaking distance. The sites with visible and those with invisible mucosal discolorations differed significantly only regarding the chroma along yellow-blue axis.
引用
收藏
页码:192 / 200
页数:9
相关论文
共 50 条
  • [1] Impact of abutment material on peri-implant soft tissue color. An in vitro study
    Sala, Leticia
    Bascones-Martinez, Antonio
    Carrillo-de-Albornoz, Ana
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (07) : 2221 - 2233
  • [2] Revisiting peri-implant soft tissue - histopathological study of the peri-implant soft tissue
    Silva, Eduarda
    Felix, Sergio
    Rodriguez-Archilla, Alberto
    Oliveira, Pedro
    dos Santos, Jose Martins
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2014, 7 (02): : 611 - 618
  • [3] Correlation between subjective and objective evaluation of peri-implant soft tissue color
    Paniz, Gianluca
    Bressan, Eriberto
    Stellini, Edoardo
    Romeo, Eugenio
    Lops, Diego
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 992 - 996
  • [4] Impact of abutment material on peri-implant soft tissue color. An in vitro study
    Leticia Sala
    Antonio Bascones-Martínez
    Ana Carrillo-de-Albornoz
    Clinical Oral Investigations, 2017, 21 : 2221 - 2233
  • [5] Spectrophotometric and Visual Evaluation of Maxillary Anterior Implant Crowns and Peri-implant Soft Tissues: A Retrospective Study
    Wong, Jin Lin
    Tan, Keson Beng Choon
    Teoh, Khim Hean
    Sim, Christina Poh Choo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (03) : 277 - 284
  • [6] Abutment Material Effect on Peri-implant Soft Tissue Color and Perceived Esthetics
    Kim, Aram
    Campbell, Stephen D.
    Viana, Marlos A. G.
    Knoernschild, Kent L.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (08): : 634 - 640
  • [7] Impact of peri-implant soft tissue characteristics on health and esthetics
    Monje, Alberto
    Gonzalez-Martin, Oscar
    Avila-Ortiz, Gustavo
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (01) : 183 - 196
  • [8] Guided Peri-Implant Autogenous Soft-Tissue Grafting: A Case Report
    Crauste, Eleonore
    Struillou, Xavier
    Lanoiselee, Edouard
    Cloitre, Alexandra
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (06) : 507 - 515
  • [9] Influence of Gingival Color and Abutment Material on the Final Color of Peri-Implant Soft Tissue: An In Vitro Analysis
    Bulent, Ibrahim
    Sermet, Ibrahim Bulent
    JOURNAL OF ORAL IMPLANTOLOGY, 2025, 51 (01) : 111 - 116
  • [10] The Influence of Initial Soft Tissue Thickness on Peri-Implant Bone Remodeling
    Vervaeke, Stijn
    Dierens, Melissa
    Besseler, Jos
    De Bruyn, Hugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (02) : 238 - 247