Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures A randomized study

被引:7
作者
Chen, Xiong [1 ]
Yu, Zheng-Xi [2 ]
Wang, Huai-Yun [3 ]
Shen, Feng [3 ]
Lin, Guo-Bing [3 ]
Wang, Sheng [3 ]
Yin, Zong-Sheng [1 ]
机构
[1] Med Univ Anhui, Dept Orthoped, Hefei 230022, Anhui, Peoples R China
[2] Putian Univ, Dept Orthoped, Affiliated Hosp, Putian, Fujian, Peoples R China
[3] Fuzhou Mil Reg Gen Hosp, Dept Orthoped, Affiliated Hosp 1, Putian, Fujian, Peoples R China
关键词
custom neutral-position shoulder and elbow sling; humeral fractures; internal fixation; internal fixation failure; PHILOS plate; PHILOS PLATE; FIXATION; OSTEOPOROSIS; MULTICENTER; OUTCOMES; NECK;
D O I
10.1097/MD.0000000000015271
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The aim of this study was to investigate the effectiveness of the proximal humeral internal locking system (PHILOS) plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures. Methods: A total of 112 patients with proximal humerus fractures were assigned randomly into 2 groups. Group A (n=56) was treated by open reduction and internal fixation (ORIF) with a PHILOS plate; group B (n=56) was treated by ORIF with a PHILOS plate in combination with the use of a custom neutral-position shoulder and elbow sling for 30 days after surgery. The incidence of internal fixation failure, the Constant-Murley shoulder assessment, and Visual Analogue Scale (VAS) score were recorded and analyzed. Results: Patients included were followed up for an average of 15 months (range, 6-24 months). No significant differences were observed in mean VAS scores and mean Constant-Murley shoulder assessment scores at 1-day preoperative and postoperative day 3 between groups A and B. However, mean VAS scores and mean Constant-Murley shoulder assessment in group B were significantly improved when compared with group A at postoperative day 30 and the final follow-up. No cases of postoperative infection, loss of reduction, PHILOS break, or vascular nerve injury occurred in either group. Conclusions: Proximal humerus fractures treated with the combination of the PHILOS and custom neutral-position shoulder and elbow sling for 30 days after operation was associated with a lower incidence of internal fixation failure. There was no increase in adverse events compared with open reduction and internal fixation with a PHILOS plate alone.
引用
收藏
页数:5
相关论文
共 39 条
  • [1] A Prospective Clinical Study of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate
    Yang, Huiguang
    Li, Zhongze
    Zhou, Feng
    Wang, Daoyuan
    Zhong, Baoliang
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) : 11 - 17
  • [2] Internal fixation of proximal humeral fractures with locking proximal humeral plate (LPHP) in elderly patients with osteoporosis
    Siwach R.
    Singh R.
    Rohilla R.K.
    Kadian V.S.
    Sangwan S.S.
    Dhanda M.
    Journal of Orthopaedics and Traumatology, 2008, 9 (3) : 149 - 153
  • [3] Pathological fractures of the proximal humerus treated with a proximal humeral locking plate and bone cement
    Siegel, H. J.
    Lopez-Ben, R.
    Mann, J. P.
    Ponce, B. A.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (05): : 707 - 712
  • [4] Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS)
    Brunner, Alexander
    Thormann, Sebastian
    Babst, Reto
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (08) : 1056 - 1063
  • [5] Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter Analysis
    Brunner, Felix
    Sommer, Christoph
    Bahrs, Christian
    Hettwinkel, Rainer
    Hafner, Christian
    Rillmann, Paavo
    Kohut, Georges
    Ekelund, Anders
    Muller, Mathias
    Audige, Laurent
    Babst, Reto
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (03) : 163 - 172
  • [6] Locking plate fixation with and without inferomedial screws for proximal humeral fractures: a biomechanical study
    Burke, Neil G.
    Kennedy, Jim
    Cousins, Grainne
    Fitzpatrick, David
    Mullett, Hannan
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (02): : 190 - 194
  • [7] Complication rate after operative treatment of three- and four-part fractures of the proximal humerus: locking plate osteosynthesis versus proximal humeral nail
    Lorenz, Greta
    Schonthaler, Wolfgang
    Huf, Wolfgang
    Komjati, Micha
    Fialka, Christian
    Boesmueller, Sandra
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2021, 47 (06) : 2055 - 2064
  • [8] Assessment of Screw Length of Proximal Humerus Internal Locking System (PHILOS) Plate for Proximal Humeral Fractures Using Three-Dimensional Computed Tomography Scan
    Qiang, Minfei
    Jia, Xiaoyang
    Chen, Yanxi
    Zhang, Kun
    Li, Haobo
    Jiang, Yuchen
    Zhang, Yijie
    MEDICAL SCIENCE MONITOR, 2018, 24 : 1158 - 1165
  • [9] Efficacy of proximal humeral internal locking system combined with allogeneic femoral head bone grafts for complex osteoporotic proximal humeral fractures
    Zhang, Jie
    Zhou, Shaojie
    Cai, Feng
    Ma, Yunmiao
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (07): : 8847 - 8854
  • [10] RETRACTED: Proximal humerus fractures treated by percutaneous locking plate internal fixation (Retracted Article)
    Rouleau, D. -M.
    Laflamme, G. -Y.
    Berry, G. K.
    Harvey, E. J.
    Delisle, J.
    Girard, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (01) : 56 - 62