Detection of vertebral metastases: a comparison between the modified Dixon turbo spin echo T2 weighted MRI and conventional T1 weighted MRI: a preliminary study in a tertiary centre

被引:26
作者
Hahn, Seok [1 ,2 ,3 ]
Lee, Young Han [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, YUHS KRIBB Med Convergence Res Inst, Dept Radiol,Res Inst Radiol Sci, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul, South Korea
[3] Inje Univ, Coll Med, Haeundae Paik Hosp, Dept Radiol, Busan, South Korea
基金
新加坡国家研究基金会;
关键词
BONE-MARROW; SKELETAL METASTASES; MALIGNANT PROCESSES; FAT FRACTION; CANCER; SEQUENCES; DIFFERENTIATION; BENIGN; PET/CT; TIMES;
D O I
10.1259/bjr.20170782
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the diagnostic performance of modified Dixon (mDixon) turbo spin echo (TSE) T-2 weighted MRI and conventional T-1 weighted MRI in vertebral metastasis detection. Methods: Between September 2014 and October 2016, 33 patients with 68 metastases who had undergone whole-spine MRI were enrolled. The following sagittal image sets were evaluated: T1WI, and mDixon TSE T-2 weighted water and fat images. Two radiologists independently evaluated each image-set for metastasis. The MR findings were compared with positron emission tomography-CT (PET-CT) scans. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each sequence. The diagnostic performance of each sequence was evaluated using receiver operating characteristic (ROC) curves. Results: Sensitivity, specificity, PPV and NPV for reviewer 1 were 83.8, 99.1, 89.1 and 98.6%, respectively, with T1WI; 79.4, 98.8, 85.7 and 98.2%, respectively, with mDixon TSE T-2 weighted water imaging; and 86.8, 99.1, 89.4 and 98.8%, respectively, with mDixon TSE T-2 weighted fat imaging. For reviewer 2, the respective scores were 91.2, 99.2, 91.2 and 99.2%; 85.3, 99.5, 93.4 and 98.7%; and 89.7, 99.3, 92.4 and 99.1%. With PET-CT as the gold standard, the ROC curves of the three sequences showed no significant difference (all p > 0.05) Conclusion: The diagnostic performance of mDixon TSE T-2 weighted water and fat imaging was comparable to that of conventional T1WI in the detection of vertebral metastases. Advances in knowledge: mDixon TSE T2WI can be a good alternative to conventional T1WI for detecting vertebral metastases.
引用
收藏
页数:9
相关论文
共 28 条
[11]   Differentiation of Acute Osteoporotic and Malignant Vertebral Fractures by Quantification of Fat Fraction With a Dixon MRI Sequence [J].
Kim, Dong Hyun ;
Yoo, Hye Jin ;
Hong, Sung Hwan ;
Choi, Ja-Young ;
Chae, Hee Dong ;
Chung, Bo Mi .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (06) :1331-1339
[12]   Quantitative evaluation of the suitability of magnetic resonance sequences for detecting skeletal metastases in the spinal bone marrow. [J].
Layer, G ;
Sommer, T ;
Busch, M ;
Schuller, H ;
Schild, HH .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (01) :20-26
[13]   Fat fraction estimation of morphologically normal lumbar vertebrae using the two-point mDixon turbo spin-echo MRI with flexible echo times and multipeak spectral model of fat: Comparison between cancer and non-cancer patients [J].
Lee, Seung Hyun ;
Lee, Young Han ;
Hahn, Seok ;
Suh, Jin-Suck .
MAGNETIC RESONANCE IMAGING, 2016, 34 (08) :1114-1120
[14]   Dixon techniques for water and fat imaging [J].
Ma, Jingfei .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) :543-558
[15]   Fast Dixon-Based Multisequence and Multiplanar MRI for Whole-Body Detection of Cancer Metastases [J].
Ma, Jingfei ;
Costelloe, Colleen M. ;
Madewell, John E. ;
Hortobagyi, Gabriel N. ;
Green, Marjorie C. ;
Cao, Guang ;
Sun, Fei ;
Kundra, Vikas .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (05) :1154-1162
[16]   Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images [J].
Maeder, Yael ;
Dunet, Vincent ;
Richard, Raphael ;
Becce, Fabio ;
Omoumi, Patrick .
RADIOLOGY, 2018, 286 (03) :853-864
[17]   VALUE OF BONE SCANNING IN NEOPLASTIC DISEASE [J].
MCNEIL, BJ .
SEMINARS IN NUCLEAR MEDICINE, 1984, 14 (04) :277-286
[18]  
MEHTA RC, 1995, AM J NEURORADIOL, V16, P281
[19]   The Value of the T2-Weighted Multipoint Dixon Sequence in MRI of Sacroiliac Joints for the Diagnosis of Active and Chronic Sacroiliitis [J].
Ozgen, Ali .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) :603-608
[20]   Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T [J].
Pokorney, Amber L. ;
Chia, Jonathan M. ;
Pfeifer, Cory M. ;
Miller, Jeffrey H. ;
Hu, Houchun H. .
ACTA RADIOLOGICA, 2017, 58 (11) :1386-1394