Lactate biosensors for continuous monitoring

被引:14
作者
Mo, JW [1 ]
Smart, W [1 ]
机构
[1] Kumetrix Inc, Electrochem Res, Union City, CA 94587 USA
来源
FRONTIERS IN BIOSCIENCE-LANDMARK | 2004年 / 9卷
关键词
lactate; biosensor; continuous monitoring; in vivo; ex vivo; resuscitation; shock; biodiagnostics; point of care; microdialysis; review;
D O I
10.2741/1489
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Blood lactate concentration is a highly sensitive measure of tissue oxygen deprivation from ischemia, trauma, and hemorrhage, which can produce life-threatening shock. Significantly, blood lactate is the most reliable end point indicator of resuscitation and predictor of survivability. The need for continuous measurement of blood lactate, and the slowness of discrete conventional photometric assays, is leading to the development of monitoring systems based on electrochemical lactate biosensors. Research and development of both in vivo and ex vivo biosensor systems is ongoing. Ex vivo biosensors are used with implanted microdialysis or ultrafiltration probes. Lactate from the blood diffuses into the dialysate/filtrate is transported outside of the body for measurement. The external biosensors are protected from fouling or contamination from unwanted blood constituents, but at the cost of an inherent delay in response despite system miniaturization. In vivo biosensors provide a direct measurement of blood lactate concentration, providing rapid response to changes in lactate levels. In vivo sensors are placed in the skin or implanted subcutaneously. Response to changes in lactate concentration is rapid, but biocompatibility requirements are more stringent than for ex vivo sensors. As is the case with all microdialysis systems, some in vivo biosensors must be implanted into the body using an insertion needle or surgical means, limiting their use. However, small, inexpensive, disposable in vivo sensors are also being developed which can emplaced and removed by the user.
引用
收藏
页码:3384 / 3391
页数:8
相关论文
共 56 条
  • [1] A CONTINUOUS, IMPLANTABLE LACTATE SENSOR
    BAKER, DA
    GOUGH, DA
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (09) : 1536 - 1540
  • [2] BAKER DA, 2004, UNPUB ANN BIOMED ENG
  • [3] Serial blood lactate levels can predict the development of multiple organ failure following septic shock
    Bakker, J
    Gris, P
    Coffernils, M
    Kahn, RJ
    Vincent, JL
    [J]. AMERICAN JOURNAL OF SURGERY, 1996, 171 (02) : 221 - 226
  • [4] NAD(+)-dependent enzyme electrodes: Electrical contact of cofactor-dependent enzymes and electrodes
    Bardea, A
    Katz, E
    Buckmann, AF
    Willner, I
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (39) : 9114 - 9119
  • [5] *BIO WISE DEP TRAD, 2001, BIOS IND APPL REV BI
  • [6] Boldt J, 2002, CRIT CARE, V6, P52
  • [7] Defining the period of recovery of the glucose concentration after its local perturbation by the implantation of a miniature sensor
    Chen, T
    Schmidtke, DW
    Heller, A
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (08) : 786 - 789
  • [8] IN-VIVO MONITORING OF LACTATE AND GLUCOSE WITH MICRODIALYSIS AND ENZYME REACTORS IN INTENSIVE-CARE MEDICINE
    DEBOER, J
    KORF, J
    PLIJTERGROENDIJK, H
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (03) : 163 - 170
  • [9] POLYACRYLAMIDE-BASED REDOX POLYMER FOR CONNECTING REDOX CENTERS OF ENZYMES TO ELECTRODES
    DELUMLEYWOODYEAR, T
    ROCCA, P
    LINDSAY, J
    DROR, Y
    FREEMAN, A
    HELLER, AA
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (08) : 1332 - 1338
  • [10] In vitro optimisation of a microdialysis system with potential for on-line monitoring of lactate and glucose in biological samples
    Dempsey, E
    Diamond, D
    Smyth, MR
    Malone, MA
    Rabenstein, K
    McShane, A
    McKenna, M
    Keaveny, TV
    Freaney, R
    [J]. ANALYST, 1997, 122 (02) : 185 - 189