Steady- and transient-state response of cold-formed steel-to-steel screwed connections at elevated temperatures

被引:21
作者
Chen, Wei [1 ,2 ]
Ye, Jihong [1 ]
Zhao, Mingyue [3 ]
机构
[1] China Univ Min & Technol, Sch Mech & Civil Engn, State Key Lab Geomech & Deep Underground Engn, Xuzhou 221116, Jiangsu, Peoples R China
[2] Key Lab Bldg Fire Protect Engn & Technol MPS, Tianjin 300381, Peoples R China
[3] Southeast Univ, Sch Civil Engn, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Cold-formed steel-to-steel screwed connection; Shear behavior; Elevated temperatures; Steady and transient state tests; Design method; Group effect; SHEAR BOLTED CONNECTIONS; THIN SHEET STEELS; TESTS; BEHAVIOR; AMBIENT; G550;
D O I
10.1016/j.jcsr.2018.01.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold-formed steel-to-steel screwed connections serve as the primary connectors in cold-formed steel framings. Most previous investigations of screwed connections focused on the failure limit states at ambient temperature. This paper presents details on single-shear experiments of cold-formed steel-to-steel screwed connections at ambient and elevated temperatures. A total of 189 steady-state tests and 36 transient-state tests are conducted. Four types of failure modes were identified, and the failure mode of the screwed connection at elevated temperatures is established to be quite similar to that of the same screwed connection under the steady-state condition of below 100 degrees C. The minimum loaded edge distance of three times the nominal diameter of the screw in AISI S240-15 is shown to be adequate for the shear design of cold-formed steel-to-steel screwed connections at elevated temperatures. The influence of design parameters, such as the screw diameter, steel type and thickness, is discussed, and the differences of the test results obtained from both transient and steady-state test methods are compared. In addition, the expressions from Laboube and Sokols' investigation are verified to be suitable for considering the group effect of two screws on the shear strength of screwed connections at elevated temperatures. The tested shear strength of cold-formed steel-to-steel screwed connections is also compared with the current AISI specification at ambient and elevated temperatures, and a conservative prediction is provided by using the reduced material properties of the corresponding steel. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 23 条
  • [21] Tests of single shear bolted connections of thin sheet steels at elevated temperatures-Part II: Transient state tests
    Yan, Shu
    Young, Ben
    [J]. THIN-WALLED STRUCTURES, 2011, 49 (10) : 1334 - 1340
  • [22] Experimental study on shear behavior of screw connections in CFS sheathing
    Ye, Jihong
    Wang, Xingxing
    Zhao, Mengyuan
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 121 : 1 - 12
  • [23] Elevated Temperature Material Degradation of Cold-Formed Steels under Steady- and Transient-State Conditions
    Ye, Jihong
    Chen, Wei
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2013, 25 (08) : 947 - 957