Nucleic acid lateral flow assays using a conjugate of a DNA binding protein and carbon nanoparticles

被引:16
作者
Aktas, Gulsen Betul [1 ]
Wichers, Jan H. [2 ]
Skouridou, Vasso [1 ]
van Amerongen, Aart [2 ]
Masip, Lluis [1 ]
机构
[1] Univ Rovira & Virgili, Dept Engn Quim, Interfibio Bioengn & Bioelectrochem Grp, 26 Paisos Catalans, E-43007 Tarragona, Spain
[2] Wageningen Univ & Res, Wageningen Food & Biobased Res, BioSensing & Diagnost, Bornse Weilanden 9, NL-6708 WG Wageningen, Netherlands
关键词
Nucleic acid lateral flow assay; Immunochromatographic test; Single-chain Cro; Enzyme conjugate; Signal enhancement; Escherichia coli; ESCHERICHIA-COLI; RAPID DETECTION; IMMUNOASSAY; BIOSENSOR; LABEL; SPP; PCR;
D O I
10.1007/s00604-019-3544-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nucleic acid lateral flow assays (NALFA) are often performed with gold nanoparticles. These are typically associated with ligand-labeled PCR amplicons via affinity interactions of adsorbed/conjugated proteins. Otherwise, they are conjugated to specific ssDNA sequences that hybridize to the target sequence. To avoid the need to generate ssDNA and to reduce the costs associated with primer labeling and antibody use, NALFA assays were developed that allow the direct detection of PCR amplicons using conjugates of a DNA binding protein with carbon nanoparticles (CNPs). The target gene encoding 16S ribosomal RNA of Escherichia coli was amplified by PCR using a single fluorophore-labeled forward primer and a reverse primer extended with the binding sequence of the bacteriophage lambda Cro repressor protein. Three different detection approaches were evaluated: (a) scCro/CNPs conjugate (black color), (b) HRP-scCro enzyme conjugate (red color), and (c) HRP-scCro/CNPs conjugate for dual color development. The limits of detection were between 6.9 and 10.4ng of PCR product for all three approaches. These correspond to 3.0 to 4.5x10(3) CFUmL(-1). The single-step scCro/CNP approach proved to be the fastest one to perform and gave no false-positive signals. It also showed a broad dynamic range even though the signal intensities were lower compared to the enzyme-amplified tests. However, the latter ones produced some background signal. In our perception, the application of scCro in lateral flow assays to bind dsDNA appears to be an excellent alternative to the use of small tags that have to be chemically linked to synthetic primers. Finally, the approach is generic because any primer sequence can be extended with the specific scCro binding sequence.
引用
收藏
页数:11
相关论文
共 34 条
[1]   Nucleic acid sensing with enzyme-DNA binding protein conjugates cascade and simple DNA nanostructures [J].
Aktas, Gulsen Betul ;
Skouridou, Vasso ;
Masip, Lluis .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (14) :3623-3632
[2]   One step visual detection of PCR products with gold nanoparticles and a nucleic acid lateral flow (NALF) device [J].
Aveyard, Jenny ;
Mehrabi, Maryam ;
Cossins, Andrew ;
Braven, Helen ;
Wilson, Robert .
CHEMICAL COMMUNICATIONS, 2007, (41) :4251-4253
[3]   Novel signal amplification approach for HRP-based colorimetric genosensors using DNA binding protein tags [J].
Betuel Aktas, Guelsen ;
Skouridou, Vasso ;
Masip, Lluis .
BIOSENSORS & BIOELECTRONICS, 2015, 74 :1005-1010
[4]   Development of a nucleic acid lateral flow immunoassay for simultaneous detection of Listeria spp. and Listeria monocytogenes in food [J].
Blazkova, Martina ;
Koets, Marjo ;
Rauch, Pavel ;
van Amerongen, Aart .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2009, 229 (06) :867-874
[5]   Lateral flow microarrays: a novel platform for rapid nucleic acid detection based on miniaturized lateral flow chromatography [J].
Carter, Darren J. ;
Cary, R. Bruce .
NUCLEIC ACIDS RESEARCH, 2007, 35 (10)
[6]   Review: Emerging Nucleic Acid Based Tests for Point-of-Care Detection of Malaria [J].
Cordray, Michael S. ;
Richards-Kortum, Rebecca R. .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2012, 87 (02) :223-230
[7]  
Dam GJVan, 2004, DIAGNOSIS SCHISTOSOM, V42, P5458, DOI [10. 1128/JCM. 42. 12. 5458, DOI 10.1128/JCM.42.12.5458]
[8]   An enzyme-amplified lateral flow strip biosensor for visual detection of MicroRNA-224 [J].
Gao, Xuefei ;
Xu, Li-Ping ;
Wu, Tingting ;
Wen, Yongqiang ;
Ma, Xinlei ;
Zhang, Xueji .
TALANTA, 2016, 146 :648-654
[9]   Quantification of bacteria adherent to gastrointestinal mucosa by real-time PCR [J].
Huijsdens, XW ;
Linskens, RK ;
Mak, MT ;
Meuwissen, SGM ;
Vandenbroucke-Grauls, CMJE ;
Savelkoul, PHM .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (12) :4423-4427
[10]   Silver Nanoparticle-Based Fluorescence-Quenching Lateral Flow Immunoassay for Sensitive Detection of Ochratoxin A in Grape Juice and Wine [J].
Jiang, Hu ;
Li, Xiangmin ;
Xiong, Ying ;
Pei, Ke ;
Nie, Lijuan ;
Xiong, Yonghua .
TOXINS, 2017, 9 (03)