Effectiveness of Low Rate Fluoroscopy at Reducing Operator and Patient Radiation Dose During Transradial Coronary Angiography and Interventions

被引:88
作者
Abdelaal, Eltigani [1 ]
Plourde, Guillaume [1 ]
MacHaalany, Jimmy [1 ]
Arsenault, Jean [1 ]
Rimac, Goran [1 ]
Dery, Jean-Pierre [1 ]
Barbeau, Gerald [1 ]
Larose, Eric [1 ]
De larochelliere, Robert [1 ]
Nguyen, Can M. [1 ]
Allende, Ricardo [1 ]
Ribeiro, Henrique [1 ]
Costerousse, Olivier [1 ]
Mongrain, Rosaire [2 ]
Bertrand, Olivier F. [1 ,2 ]
机构
[1] Univ Laval, Quebec Heart Lung Inst, Quebec City, PQ, Canada
[2] McGill Univ, Dept Mech Engn, Montreal, PQ, Canada
关键词
dosimetry; imaging; percutaneous coronary intervention; radiation; transradial; FEMORAL ACCESS; CARDIAC-CATHETERIZATION; TRANSFEMORAL APPROACH; PROTECTION DEVICES; EXPOSURE; CARDIOLOGY; REDUCTION; EXPERIENCE; IMPACT; SAFETY;
D O I
10.1016/j.jcin.2014.02.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study sought to determine the efficacy of low rate fluoroscopy at 7.5 frames/s (FPS) versus conventional 15 FPS for reduction of operator and patient radiation dose during diagnostic coronary angiography (DCA) and percutaneous coronary intervention (PCI) via the transradial approach (TRA). Background TRA for cardiac catheterization is potentially associated with increased radiation exposure. Low rate fluoroscopy has the potential to reduce radiation exposure. Methods Patients undergoing TRA diagnostic angiography +/- ad-hoc PCI were randomized to fluoroscopy at 7.5 FPS versus 15 FPS prior to the procedure. Both 7.5 and 15 FPS fluoroscopy protocols were configured with a fixed dose per pulse of 40 nGy. Primary endpoints were operator radiation dose (measured with dosimeter attached to the left side of the thyroid shield in mu Sievert [mu Sv]), patient radiation dose (expressed as dose-area product in Gy.cm(2)), and fluoroscopy time. Results From October 1, 2012 to August 30, 2013, from a total of 363 patients, 184 underwent DCA and 179 underwent PCI. Overall, fluoroscopy at 7.5 FPS compared with 15 FPS was associated with a significant reduction in operator dose (30% relative reduction [RR], p < 0.0001); and in patient's dose-area product (19% RR; p = 0.022). When stratified by procedure type, 7.5 FPS compared with 15 FPS was associated with significant reduction in operator dose during both DCA (40% RR; p < 0.0001) and PCI (28% RR; p = 0.0011). Fluoroscopy at 7.5 FPS, compared with 15 FPS, was also associated with substantial reduction in patients' dose-area product during DCA (26% RR; p = 0.0018) and during PCI (19% RR; p = 0.13). Fluoroscopy time was similar in 7.5 FPS and 15 FPS groups for DCA (3.4 +/- 2.0 min vs. 4.0 +/- 4.7 min; p = 0.42) and PCI (11.9 +/- 8.4 min vs. 13.3 +/- 9.7 min; p = 0.57), respectively. Conclusions Fluoroscopy at 7.5 FPS, compared with 15 FPS, is a simple and effective method in reducing operator and patient radiation dose during TRA DCA and PCI. (C) 2014 by the American College of Cardiology Foundation
引用
收藏
页码:567 / 574
页数:8
相关论文
共 35 条
[1]   Successive transradial access for coronary procedures: Experience of Quebec Heart-Lung Institute [J].
Abdelaal, Eltigani ;
Molin, Pierre ;
Plourde, Guillaume ;
MacHaalany, Jimmy ;
Bataille, Yoann ;
Brousseau-Provencher, Cynthia ;
Montminy, Sarah ;
Larose, Eric ;
Roy, Louis ;
Gleeton, Onil ;
Barbeau, Gerald ;
Nguyen, Can M. ;
Noel, Bernard ;
Costerousse, Olivier ;
Bertrand, Olivier F. .
AMERICAN HEART JOURNAL, 2013, 165 (03) :325-331
[2]   Transradial Versus Transfemoral Approach for Coronary Angiography and Intervention in Patients Above 75 Years of Age [J].
Achenbach, Stephan ;
Ropers, Dieter ;
Kallert, Lisa ;
Turan, Nesrin ;
Kraehner, Robert ;
Wolf, Tobias ;
Garlichs, Christoph ;
Flachskampf, Frank ;
Daniel, Werner G. ;
Ludwig, Josef .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (05) :629-635
[3]   Decreasing Operators' Radiation Exposure During Coronary Procedures: The Transradial Radiation Protection Board [J].
Behan, Miles ;
Haworth, Peter ;
Colley, Paul ;
Brittain, Michael ;
Hince, Andrew ;
Clarke, Michael ;
Ghuran, Azad ;
Saha, Mrinal ;
Hildick-Smith, David .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (01) :79-84
[4]   Operator vs. patient radiation exposure in transradial and transfemoral coronary interventions [J].
Bertrand, Olivier F. ;
Arsenault, Jean ;
Mongrain, Rosaire .
EUROPEAN HEART JOURNAL, 2008, 29 (20) :2577-2578
[5]   A randomized study comparing same-day home discharge and abciximab bolus only to overnight hospitalization and abciximab bolus and infusion after transradial coronary stent implantation [J].
Bertrand, Olivier F. ;
De Larochelliere, Robert ;
Rodes-Cabau, Josep ;
Proulx, Guy ;
Gleeton, Onil ;
Nguyen, Can Manh ;
Dery, Jean-Pierre ;
Barbeau, Gerald ;
Noel, Bernard ;
Larose, Eric ;
Poirier, Paul ;
Roy, Louis .
CIRCULATION, 2006, 114 (24) :2636-2643
[6]   Comparison of transradial and femoral approaches for percutaneous coronary interventions: A systematic review and hierarchical Bayesian meta-analysis [J].
Bertrand, Olivier F. ;
Belisle, Patrick ;
Joyal, Dominique ;
Costerousse, Olivier ;
Rao, Sunil V. ;
Jolly, Sanjit S. ;
Meerkin, David ;
Joseph, Lawrence .
AMERICAN HEART JOURNAL, 2012, 163 (04) :632-648
[7]   Comparison of operator radiation exposure with optimized radiation protection devices during coronary angiograms and ad hoc percutaneous coronary interventions by radial and femoral routes [J].
Brasselet, Camille ;
Blanpain, Thierry ;
Tassan-Mangina, Sophie ;
Deschildre, Alain ;
Duval, Sebastien ;
Vitry, Fabien ;
Gaillot-Petit, Nathalie ;
Clement, Jean Paul ;
Metz, Damien .
EUROPEAN HEART JOURNAL, 2008, 29 (01) :63-70
[8]   A Randomized Comparison of Transradial Versus Transfemoral Approach for Coronary Angiography and Angioplasty [J].
Brueck, Martin ;
Bandorski, Dirk ;
Kramer, Wilfried ;
Wieczorek, Marcus ;
Hoeltgen, Reinhard ;
Tillmanns, Harald .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1047-1054
[9]   Radiation Safety Program for the Cardiac Catheterization Laboratory [J].
Chambers, Charles E. ;
Fetterly, Kenneth A. ;
Holzer, Ralf ;
Lin, Pei-Jan Paul ;
Blankenship, James C. ;
Balter, Stephen ;
Laskey, Warren K. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (04) :546-556
[10]   Radiation exposure to cardiologists performing interventional cardiology procedures [J].
Delichas, M ;
Psarrakos, K ;
Molyvda-Athanassopoulou, E ;
Giannoglou, G ;
Sioundas, A ;
Hatziioannou, K ;
Papanastassiou, E .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (03) :268-273