Phase contrast imaging using a micro focus x-ray source

被引:0
作者
Zhou, Wei [1 ]
Majidi, Keivan [2 ]
Brankov, Jovan G. [2 ]
机构
[1] IIT, BME Dept, 3300 S Fed St, Chicago, IL 60616 USA
[2] IIT, ECE Dept, Chicago, IL 60616 USA
来源
ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IX | 2014年 / 9207卷
关键词
phase contrast; x ray; imaging; crystal; germanium; analyzer;
D O I
10.1117/12.2060749
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Phase contrast x-ray imaging, a new technique to increase the imaging contrast for the tissues with close attenuation coefficients, has been studied since mid 1990s. This technique reveals the possibility to show the clear details of the soft tissues and tumors in small scale resolution. A compact and low cost phase contrast imaging system using a conventional x-ray source is described in this paper. Using the conventional x-ray source is of great importance, because it provides the possibility to use the method in hospitals and clinical offices. Simple materials and components are used in the setup to keep the cost in a reasonable and affordable range. Tungsten K alpha(1) line with the photon energy 59.3 keV was used for imaging. Some of the system design details are discussed. The method that was used to stabilize the system is introduced. A chicken thigh bone tissue sample was used for imaging followed by the image quality, image acquisition time and the potential clinical application discussion. High energy x-ray beam can be used in phase contrast imaging. Therefore the radiation dose to the patients can be greatly decreased compared to the traditional x-ray radiography.
引用
收藏
页数:8
相关论文
共 16 条
[1]   Computed tomography implementation of multiple-image radiography [J].
Brankov, JG ;
Wernick, MN ;
Yang, YY ;
Li, J ;
Muehleman, C ;
Zhong, Z ;
Anastasio, MA .
MEDICAL PHYSICS, 2006, 33 (02) :278-289
[2]   ASYMMETRICALLY CUT CRYSTALS AS OPTICAL-ELEMENTS FOR HIGHLY COLLIMATED X-RAY-BEAMS [J].
BRAUER, S ;
STEPHENSON, GB ;
SUTTON, M ;
MOCHRIE, SGJ ;
DIERKER, SB ;
FLEMING, RM ;
PINDAK, R ;
ROBINSON, IK ;
GRUBEL, G ;
ALSNIELSEN, J ;
ABERNATHY, DL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1506-1509
[3]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[4]   PHASE-CONTRAST IMAGING OF WEAKLY ABSORBING MATERIALS USING HARD X-RAYS [J].
DAVIS, TJ ;
GAO, D ;
GUREYEV, TE ;
STEVENSON, AW ;
WILKINS, SW .
NATURE, 1995, 373 (6515) :595-598
[5]   Application of absorption and refraction matching techniques for diffraction enhanced imaging [J].
Hasnah, M ;
Oltulu, O ;
Zhong, Z ;
Chapman, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03) :1657-1659
[6]   NATURAL WIDTHS OF ATOMIC K-LEVELS AND L-LEVELS,K-ALPHA X-RAY-LINES AND SEVERAL KLL AUGER LINES [J].
KRAUSE, MO ;
OLIVER, JH .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1979, 8 (02) :329-338
[7]   Molybdenum microfocus source coupling to polycapillary optics for powder diffraction [J].
Mail, N ;
Gibson, WM ;
MacDonald, CA .
ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS III, 2002, 4781 :87-95
[8]   Multiple-image radiography for human soft tissue [J].
Muehleman, C ;
Li, J ;
Zhong, Z ;
Brankov, JG ;
Wernick, MN .
JOURNAL OF ANATOMY, 2006, 208 (01) :115-124
[9]   In-Laboratory Diffraction-Enhanced X-ray Imaging for Articular Cartilage [J].
Muehleman, Carol ;
Fogarty, Daniel ;
Reinhart, Benjamin ;
Tzvetkov, Tochko ;
Li, Jun ;
Nesch, Ivan .
CLINICAL ANATOMY, 2010, 23 (05) :530-538
[10]   The design and application of an in-laboratory diffraction-enhanced x-ray imaging instrument [J].
Nesch, Ivan ;
Fogarty, Daniel P. ;
Tzvetkov, Tochko ;
Reinhart, Benjamin ;
Walus, A. Charles ;
Khelashvili, Gocha ;
Muehleman, Carol ;
Chapman, Dean .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (09)