Changes in intraocular pressure after intraocular eye surgery-the influence of measuring technique

被引:2
作者
Kovacic, Hrvoje [1 ]
Wolfs, Roger C. W. [1 ]
Kilic, Emine [1 ]
Ramdas, Wishal D. [1 ]
机构
[1] Erasmus MC, Dept Ophthalmol, NL-3000 CA Rotterdam, Netherlands
关键词
glaucoma; intraocular pressure; intraocular surgery; trans pars plana vitrectomy; DYNAMIC CONTOUR TONOMETRY; GOLDMANN APPLANATION TONOMETRY; CENTRAL CORNEAL THICKNESS; OPEN-ANGLE GLAUCOMA; CATARACT-SURGERY; PHACOEMULSIFICATION; VITRECTOMY; REDUCTION; PARAMETERS; ELEVATION;
D O I
10.18240/ijo.2019.06.14
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To investigate the changes in intraocular pressure (IOP) before and after intraocular surgery measured with Goldmann applanation tonometry (GAT) and pascal dynamic contour tonometry (PDCT), and assessed their agreement. METHODS: Patients who underwent trans pars plana vitrectomy (TPPV) with or without cataract extraction (CE) were included. The IOP was measured in both eyes with GAT and PDCT pre- and postoperatively, where the non-operated eyes functioned as control. RESULTS: Preoperatively, mean IOP measurements were 16.3 +/- 6.0 mm Hg for GAT and 12.0 +/- 2.8 mm Hg for PDCT for the operated eyes. Postoperatively, the mean IOP dropped to 14.3 +/- 5.6 mm Hg for GAT (P=0.011) and rose up to 12.7 +/- 2.6 mm Hg for PDCT (P=0.257). Bland-Altman analysis showed a poor agreement between GAT and PDCT with a mean difference of 2.9 mm Hg preoperatively and 95% limits of agreement ranging from -3.2 to 9.0 mm Hg. Postoperatively, the mean difference was 1.2 mm Hg with 95% limits of agreement ranging from -8.3 to 10.7 mm Hg. There were no significant differences between the TPPV and TPPV+CE group, except when measured with PDCT postoperatively (P=0.012). CONCLUSION: The IOP is reduced after surgery when measured with GAT and remained stable when measured with PDCT. However, the agreement between GAT and PDCT is poor. Although PDCT may be a more accurate predictor of the true IOP, it seems less suitable for daily use in the clinical practice.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 40 条
[1]  
Albis-Donado Oscar, 2018, J Curr Glaucoma Pract, V12, P40, DOI 10.5005/jp-journals-10028-1242
[2]   Comparison of the Utility of Pascal Dynamic Contour Tonometry With Goldmann Applanation Tonometry in Routine Clinical Practice [J].
Anderson, Matthew Frederick ;
Agius-Fernandez, Adriana ;
Kaye, Stephen B. .
JOURNAL OF GLAUCOMA, 2013, 22 (05) :422-426
[3]   The Effects of Phacoemulsification on Intraocular Pressure and Topical Medication Use in Patients With Glaucoma: A Systematic Review and Meta-analysis of 3-Year Data [J].
Armstrong, James J. ;
Wasiuta, Tomas ;
Kiatos, Efstathia ;
Malvankar-Mehta, Monali ;
Hutnik, Cindy M. L. .
JOURNAL OF GLAUCOMA, 2017, 26 (06) :511-522
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   LXII Edward Jackson lecture: Open angle glaucoma after vitrectomy [J].
Chang, Stanley .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (06) :1033-1043
[6]   Lens Position Parameters as Predictors of Intraocular Pressure Reduction After Cataract Surgery in Glaucomatous Versus Nonglaucomatous Eyes [J].
Coh, Paul ;
Moghimi, Sasan ;
Chen, Rebecca I. ;
Hsu, Chi-Hsin ;
Masis Solano, Marisse ;
Porco, Travis ;
Lin, Shan C. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (06) :2593-2599
[7]   Central Corneal Thickness and Biomechanical Changes After Clear Corneal Phacoemulsification [J].
de Freitas, Bruno ;
Ventura, Marcelo Palis ;
da Silva, Renata Siqueira ;
Canedo, Ana Laura ;
Velarde, Guillermo Coca ;
Ambrosio, Renato, Jr. .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) :215-219
[8]   PASCAL DYNAMIC CONTOUR TONOMETRY VERSUS GOLDMANN APPLANATION TONOMETRY IN GAS AND AIR-FILLED EYES AFTER VITRECTOMY SURGERY [J].
Donaldson, Mark J. ;
Bhatnagar, Pawan ;
Dhrami-Gavazi, Elona ;
Santos, Rodrigo A. V. ;
Barile, Gaetano R. ;
Del Priore, Lucian V. ;
Iranmanesh, Reza ;
Schiff, William M. ;
Chang, Stanley .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (04) :481-486
[9]   Dynamic contour tonometry for post-LASIK intraocular pressure measurements [J].
Duba, I ;
Wirthlin, AC .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2004, 221 (05) :347-350
[10]   INTRAOCULAR PRESSURE CHANGES DURING VITRECTOMY USING CONSTELLATION VISION SYSTEM'S INTRAOCULAR PRESSURE CONTROL FEATURE [J].
Falabella, Paulo ;
Stefanini, Francisco R. ;
Lue, Jaw-Chyng L. ;
Pfister, Marcel ;
Reyes-Mckinley, Jahlyn ;
Koss, Michael J. ;
Teixeira, Anderson ;
Schor, Paulo ;
Humayun, Mark S. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (07) :1275-1280