Development of a portable alpha-beta-gamma radioactive material continuous air-monitoring system

被引:8
作者
Morishita, Yuki [1 ]
机构
[1] Japan Atom Energy Agcy, Collaborat Labs Adv Decommissioning Sci, 790-1 Motooka Ohtsuka,, Fukushima, Futaba Cty 9791151, Japan
关键词
Phoswich detector; Pulse-shape discrimination; Radon; Continuous air-monitoring system;
D O I
10.1016/j.nima.2021.166258
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
During the decommissioning process of nuclear facility sites, such as the Fukushima Daiichi Nuclear Power Station (FDNPS), radioactive contamination due to alpha, beta, and gamma nuclides is present. To accurately detect these nuclides, a new phoswich alpha/beta/gamma detector is proposed and developed. A portable alpha/beta/gamma radiation continuous air-monitoring system is also developed using the proposed phoswich detector for detecting unknown radioactive air contamination. The developed phowich detector features a 6 mm x 6 mm x 6 mm-stilbene scintillator (first layer) and a 6 mm x 6 mm x 6 mm-Gd-3(Ga, Al)(5)O-12(Ce) (GAGG) scintillator (second layer). The bottom of the GAGG scintillator is optically coupled to a silicon photomultiplier (SiPM). The proposed phoswich detector is capable of successfully separating alpha, beta, and gamma nuclides by applying the pulse-shape discrimination (PSD) technique. The alpha energy resolution of the 5.5 MeV alpha particles using was 22.1 +/- 0.21% at the full width at half maximum (FWHM), whereas the gamma energy resolution of the 0.662 MeV gamma rays was 10.3 +/- 0.18%FWHM. The energy spectra obtained from the simulations agree well with those obtained from measurements. Continuous alpha-nuclide air measurements were conducted in the basement of a concrete building, where the Rn-222 concentration was approximately 200 Bq/m(3), using the developed portable continuous air-monitoring system. The measured peaks, which correspond to Bi-12 (6.1 MeV),Po-214 (7.7 MeV), and Po-212 (8.8 MeV), were observed in the alpha spectrum by separating beta and gamma rays. Therefore, the developed monitoring system can be potentially efficient for the early detection of unknown released radioactive materials.
引用
收藏
页数:7
相关论文
共 15 条
[1]   Study of the background on a ZnS(Ag) alpha counter with a plastic veto detector [J].
Ardid, M ;
Ferrero, JL ;
Herrero, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 557 (02) :510-515
[2]   Characterization of a Large Area ZnS(Ag) Detector for Gross Alpha and Beta Activity Measurements in Tap Water Plants [J].
Bodewits, E. ;
Cester, D. ;
Lunardon, M. ;
Moretto, S. ;
Schotanus, P. ;
Stevanato, L. ;
Viesti, G. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) :1565-1569
[3]  
CRITES TR, 1994, RADIAT PROT DOSIM, V53, P65
[4]   Utilization of wavelength-shifting fibers coupled to ZnS(Ag) and plastic scintillator for simultaneous detection of alpha/beta particles [J].
Ifergan, Y. ;
Dadon, S. ;
Israelashvili, I. ;
Osovizky, A. ;
Gonen, E. ;
Yehuda-Zada, Y. ;
Smadja, D. ;
Knafo, Y. ;
Ginzburg, D. ;
Kadmon, Y. ;
Cohen, Y. ;
Mazor, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 :93-96
[5]   Recent progress of MPPC-based scintillation detectors in high precision X-ray and gamma-ray imaging [J].
Kataoka, J. ;
Kishimoto, A. ;
Fujita, T. ;
Nishiyama, T. ;
Kurei, Y. ;
Tsujikawa, T. ;
Oshima, T. ;
Taya, T. ;
Iwamoto, Y. ;
Ogata, H. ;
Okochi, H. ;
Ohsuka, S. ;
Ikeda, H. ;
Yamamoto, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 :248-254
[6]  
Knoll G.F, 2010, Radiation detection and measurement
[7]   A MORE RUGGED ZNS(AG) ALPHA-SCINTILLATION DETECTOR [J].
MCELHANEY, SA ;
RAMSEY, JA ;
BAUER, ML ;
CHILES, MM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :868-872
[8]   Organic scintillator-based alpha/beta detector for radiological decontamination [J].
Morishita, Y. ;
Di Fulvio, A. ;
Clarke, S. D. ;
Kearfot, K. J. ;
Pozz, S. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 935 :207-213
[9]   Detection of alpha particle emitters originating from nuclear fuel inside reactor building of Fukushima Daiichi Nuclear Power Plant [J].
Morishita, Yuki ;
Torii, Tatsuo ;
Usami, Hiroshi ;
Kikuchi, Hiroyuki ;
Utsugi, Wataru ;
Takahira, Shiro .
SCIENTIFIC REPORTS, 2019, 9 (1)
[10]   Flexible alpha camera for detecting plutonium contamination [J].
Morishita, Yuki ;
Yamamoto, Seiichi ;
Izaki, Kenji ;
Kaneko, Junichi H. ;
Nemoto, Norio .
RADIATION MEASUREMENTS, 2017, 103 :33-38