Detection of stator faults in induction machines using residual saturation harmonics

被引:58
作者
Nandi, Subhasis [1 ]
机构
[1] Univ Victoria, Dept Elect & Comp Engn, Victoria, BC V8W 3P6, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
induction motors; saturation harmonics; stator fault;
D O I
10.1109/TIA.2006.880838
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Stator fault is one of the most commonly occurring faults in ac machines. Recent estimates suggest that 30%-40% of all reported induction machine faults are stator fault related. Going by the number of occurrences, the position of stator faults is only second to bearing-related faults. Third harmonic line currents, which are caused by the interaction of a reverse-rotating field and saturation-related permeance variation, the third harmonic component in the line voltage, and the speed ripple consequent to the reverse-rotating field, have been reported to increase under stator fault conditions. Since the reverse-rotating field is produced by voltage unbalance as well as stator faults the measurement of third harmonic in the line current may not be a reliable estimator of stator faults, particularly at an incipient stage. The third and the other triplen-related harmonics are however found to be a very decisive indicator of the fault if measured in the machine terminal voltages just after switch-off. The fault-detection technique is independent of machine parameters and supply unbalances. Simulation and experimental results with very few shorted turns show that not only the presence of stator fault but also the phase in which the fault has occurred can be detected reliably. However, because of the nature of detection, it should strictly be called an offline method that can only validate existing online schemes, unless used for motors operating continuously in transient modes or form-wound machines.
引用
收藏
页码:1201 / 1208
页数:8
相关论文
共 23 条
[1]  
AKRAN M, 2001, P IEE ELECT POWER AP, V148, P537
[2]  
[Anonymous], P IEEE IAS ANN M C S
[3]   Induction motors' faults detection and localization using stator current advanced signal processing techniques [J].
Benbouzid, MEH ;
Vieira, M ;
Theys, C .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (01) :14-22
[4]   Online stator winding fault diagnosis in inverter-fed AC machines using high-frequency signal injection [J].
Briz, F ;
Degner, MW ;
Zamarrón, A ;
Guerrero, JM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (04) :1109-1117
[5]  
COLLAMATI L, 1996, P IEEE MELECON 96, V1, P495
[6]   Diagnosis of stator inter-turn short circuits in DTC induction motor drives [J].
Cruz, SMA ;
Cardoso, AJM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (05) :1349-1360
[7]   A new algorithm for transient motor current signature analysis using wavelets [J].
Douglas, H ;
Pillay, P ;
Ziarani, AK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (05) :1361-1368
[8]   The detection of inter-turn short circuits in the stator windings of operating motors [J].
Joksimovic, GM ;
Penman, J .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :1078-1084
[9]  
Kliman GB, 1996, IEEE IND APPLIC SOC, P687, DOI 10.1109/IAS.1996.557113
[10]   Condition monitoring of stator windings in induction motors: Part I - Experimental investigation of the effective negative-sequence impedance detector [J].
Kohler, JL ;
Sottile, J ;
Trutt, FC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (05) :1447-1453