Continuous glucose monitoring and 1-h plasma glucose identifies glycemic variability and dysglycemia in high-risk individuals with HbA1c < 5.7%: a pilot study

被引:8
作者
Dorcely, Brenda [1 ]
Sifonte, Eliud [1 ]
Popp, Collin [2 ]
Divakaran, Anjana [1 ]
Katz, Karin [1 ]
Musleh, Sarah [3 ]
Jagannathan, Ram [4 ]
Curran, Margaret [2 ]
Sevick, Mary Ann [1 ,2 ]
Aleman, Jose O. [1 ]
Goldberg, Ira J. [1 ]
Bergman, Michael [1 ,2 ]
机构
[1] NYU, Dept Med, Div Endocrinol Diabet & Metab, Grossman Sch Med, New York, NY 10016 USA
[2] NYU, Dept Populat Hlth, Grossman Sch Med, New York, NY 10016 USA
[3] Hawaii Permanente Med Grp, Dept Endocrinol Diabet & Metab & Internal Med, Honolulu, HI 96814 USA
[4] Emory Univ, Div Hosp Med, Sch Med, Atlanta, GA 30322 USA
关键词
LEVEL;
D O I
10.1007/s12020-022-03109-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:403 / 407
页数:5
相关论文
共 17 条
[1]   One-hour plasma glucose concentration and the metabolic syndrome identify subjects at high risk for future type 2 diabetes [J].
Abdul-Ghani, Muhammad A. ;
Abdul-Ghani, Tamam ;
Ali, Nibal ;
DeFronzo, Ralph A. .
DIABETES CARE, 2008, 31 (08) :1650-1655
[2]   Standards of Medical Care in Diabetes-2014 [J].
不详 .
DIABETES CARE, 2014, 37 :S14-S80
[3]  
[Anonymous], 2019, IDF DIABETES ATLAS
[4]   Pitfalls of HbA1c in the Diagnosis of Diabetes [J].
Bergman, Michael ;
Abdul-Ghani, Muhammad ;
Neves, Joao Sergio ;
Monteiro, Mariana P. ;
Medina, Jose Luiz ;
Dorcely, Brenda ;
Buysschaert, Martin .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2020, 105 (08) :2803-2811
[5]   One-hour post-load plasma glucose level during the OGTT predicts dysglycemia Observations from the 24 year follow-up of the Israel Study of Glucose Intolerance, Obesity and Hypertension [J].
Bergman, Michael ;
Chetrit, Angela ;
Roth, Jesse ;
Jagannathan, Ram ;
Sevick, Mary ;
Dankner, Rachel .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 120 :221-228
[6]   The Pros and Cons of Diagnosing Diabetes With A1C [J].
Bonora, Enzo ;
Tuomilehto, Jaakko .
DIABETES CARE, 2011, 34 :S184-S190
[7]   Elevated 1-h postload plasma glucose levels identify coronary heart disease patients with greater severity of coronary artery lesions and higher risk of 1-year re-admission [J].
Cao, Lifei ;
Wang, Ping ;
Luan, Hui ;
Chen, Hui ;
Luo, Chaodi ;
Zhu, Danjun ;
Tian, Gang .
DIABETES & VASCULAR DISEASE RESEARCH, 2020, 17 (01)
[8]  
Hanefeld Markolf, 2014, J Diabetes Sci Technol, V8, P286
[9]   Normal Reference Range for Mean Tissue Glucose and Glycemic Variability Derived from Continuous Glucose Monitoring for Subjects Without Diabetes in Different Ethnic Groups [J].
Hill, Nathan R. ;
Oliver, Nick S. ;
Choudhary, Pratik ;
Levy, Jonathan C. ;
Hindmarsh, Peter ;
Matthews, David R. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (09) :921-928
[10]   The 1-hour post-load glucose level is more effective than HbA1c for screening dysglycemia [J].
Jagannathan, Ram ;
Sevick, Mary Ann ;
Fink, Dorothy ;
Dankner, Rachel ;
Chetrit, Angela ;
Roth, Jesse ;
Buysschaert, Martin ;
Bergman, Michael .
ACTA DIABETOLOGICA, 2016, 53 (04) :543-550