A Lower-Back Exoskeleton With a Four-Bar Linkage Structure for Providing Extensor Moment and Lumbar Traction Force

被引:9
作者
Moon, Chaerim [1 ]
Bae, Jangho [2 ]
Kwak, Jaewon [1 ]
Hong, Daehie [1 ]
机构
[1] Korea Univ, Dept Mech Engn, Seoul 02841, South Korea
[2] Kyungsung Univ, Dept Mech & Automot Engn, Busan 48434, South Korea
关键词
Force; Exoskeletons; Back; Muscles; Springs; Dynamics; Hip; four-bar linkage; surface electromyography; lower back pain; lumbar traction force; RISK-FACTORS; SURFACE ELECTROMYOGRAPHY; MUSCLE COACTIVATION; BIOMECHANICAL MODEL; ERECTOR SPINAE; FOLLOW-UP; PAIN; DEVICE; LIFT; EMG;
D O I
10.1109/TNSRE.2022.3159178
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Lower back pain and related injuries are prevalent and serious problems in various industries, and high compression force to the lumbosacral (L5/S1) region has been known as one of the key factors. Previous research on passive lower back exoskeletons focused on reducing lumbar muscle activation by providing an extensor moment. Additionally, lumbar traction forces can reduce the compression force, and is a common treatment method for lower back pain in clinics. In this paper, we propose a novel passive lower back exoskeleton that provides both extensor moment and lumbar traction force. The working principle of the exoskeleton, extending the coil springs during lumbar flexion, and its design criteria regarding the amount of each force element were provided. The kinematic model explained its operation, and the dynamic simulation estimated its performance and validated its satisfaction with the design criteria. The biomechanical model provided a brief insight into the expected exoskeleton's effect on the reduced lower back compression force. Ten subjects performed static holding and dynamic lifting tasks, and the generated force elements in two directions, parallel and perpendicular to the trunk, were evaluated using a force sensor and electromyography sensors, respectively. The experiment demonstrated a pulling force opposite to the direction of intradiscal pressure and reduced erector spinae activation. This implies the effect of wearing the exoskeleton to decrease the intervertebral pressure during static back bending or heavy lifting tasks.
引用
收藏
页码:729 / 737
页数:9
相关论文
共 53 条
[1]   The effect of on-body lift assistive device on the lumbar 3D dynamic moments and EMG during asymmetric freestyle lifting [J].
Abdoli-E, Mohammad ;
Stevenson, Joan M. .
CLINICAL BIOMECHANICS, 2008, 23 (03) :372-380
[2]   An on-body personal lift augmentation device (PLAD) reduces EMG amplitude of erector spinae during lifting tasks [J].
Abdoli-E, Mohammad ;
Agnew, Michael J. ;
Stevenson, Joan M. .
CLINICAL BIOMECHANICS, 2006, 21 (05) :456-465
[3]   Mathematical and empirical proof of principle for an on-body personal lift augmentation device (PLAD) [J].
Abdoli-Eramaki, Mohammad ;
Stevenson, Joan M. ;
Reid, Susan A. ;
Bryant, Timothy J. .
JOURNAL OF BIOMECHANICS, 2007, 40 (08) :1694-1700
[4]   A passive exoskeleton reduces peak and mean EMG during symmetric and asymmetric lifting [J].
Alemi, Mohammad Mehdi ;
Geissinger, Jack ;
Simon, Athulya A. ;
Chang, S. Emily ;
Asbeck, Alan T. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2019, 47 :25-34
[5]   A BIOMECHANICAL MODEL OF THE LUMBOSACRAL JOINT DURING LIFTING ACTIVITIES [J].
ANDERSON, CK ;
CHAFFIN, DB ;
HERRIN, GD ;
MATTHEWS, LS .
JOURNAL OF BIOMECHANICS, 1985, 18 (08) :571-584
[6]   EPIDEMIOLOGIC ASPECTS ON LOW-BACK-PAIN IN INDUSTRY [J].
ANDERSSON, GBJ .
SPINE, 1981, 6 (01) :53-60
[7]   Biomechanics of changes in lumbar posture in static lifting [J].
Arjmand, N ;
Shirazi-Adl, A .
SPINE, 2005, 30 (23) :2637-2648
[8]   The effects of a passive exoskeleton on muscle activity, discomfort and endurance time in forward bending work [J].
Bosch, Tim ;
van Eck, Jennifer ;
Knitel, Karlijn ;
de Looze, Michiel .
APPLIED ERGONOMICS, 2016, 54 :212-217
[9]   CHANGE OF DISK HEIGHT, RADIAL DISK BULGE, AND INTRADISCAL PRESSURE FROM DISCECTOMY - AN INVITRO INVESTIGATION ON HUMAN LUMBAR DISKS [J].
BRINCKMANN, P ;
GROOTENBOER, H .
SPINE, 1991, 16 (06) :641-646
[10]  
Chaffin D.B., 1984, OCCUPATIONAL BIOMECH