Simultaneous measurements of refraction and A-scan biometry during accommodation in humans

被引:59
作者
Ostrin, Lisa [1 ]
Kasthurirangan, Sanjeev [1 ]
Win-Hall, Dorothy [1 ]
Glasser, Adrian [1 ]
机构
[1] Univ Houston, Coll Optometry, Houston, TX 77004 USA
关键词
A-scan biometry; lens thickness; anterior chamber depth; voluntary accommodation; accommodative mechanism;
D O I
10.1097/01.opx.0000232810.61191.02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Accommodation is a dioptric change in power of the crystalline lens resulting from ciliary muscle contraction that leads to an increase in lens surface curvatures and thickness and changes in the position of lens surfaces. Previous studies have used A-scan ultrasound to measure changes in the position of lens surfaces with voluntary accommodation, but have not simultaneously measured the change in refraction. The goal of this study is to simultaneously measure and correlate refractive and biometric changes in the lens during voluntary accommodation in humans. Methods. Refraction was measured off-axis in the right eye and biometry on-axis in the left eye simultaneously during voluntary accommodation in 22 human subjects between the ages of 21 and 30 years (mean standard deviation: 25.8 +/- 2.3 years). Subjects viewed a distant target and four near targets spanning the full accommodative range available to evaluate refraction and lens surface position at each accommodative state. Results. Maximum objectively measured accommodative amplitude of all subjects was 5.64 +/- 0.21 D (mean +/- standard error of mean). Biometric and refractive changes during accommodation were linearly correlated. The mean standard error of mean decrease in anterior chamber depth was 0.051 +/- 0.008 mm/D, increase in lens thickness was 0.067 +/- 0.008 mm/D, and increase in anterior segment length was 0.017 +/- 0.005 mm/D during accommodation. There was a net anterior movement of the lens center of 0.017 +/- 0.005 mm/D. Conclusion. Anterior chamber depth, lens thickness, and anterior segment length change linearly with refraction during accommodation. Per-diopter changes in the lens were greater in the current study compared with previous studies in which only accommodative demand was measured, which overestimates the accommodative response.
引用
收藏
页码:657 / 665
页数:9
相关论文
共 61 条
[21]  
FINDL O, 2001, CURRENT ASPECTS HUMA
[22]  
Garner LF, 1997, OPHTHAL PHYSL OPT, V17, P12, DOI 10.1111/j.1475-1313.1997.tb00518.x
[23]   Accommodative changes in lens diameter in rhesus monkeys [J].
Glasser, A ;
Wendt, M ;
Ostrin, L .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (01) :278-286
[24]   The mechanism of accommodation in primates [J].
Glasser, A ;
Kaufman, PL .
OPHTHALMOLOGY, 1999, 106 (05) :863-872
[25]  
GWIAZDA J, 1993, INVEST OPHTH VIS SCI, V34, P690
[26]  
HAMASAKI D, 1956, Am J Optom Arch Am Acad Optom, V33, P3
[27]  
HOKODA SC, 1982, OPHTHAL PHYSL OPT, V2, P205
[28]  
Keeney AH, 1995, DICT OPHTHALMIC OPTI
[29]   Phakometric measurement of ocular surface radii of curvature, axial separations and alignment in relaxed and accommodated human eyes [J].
Kirschkamp, T ;
Dunne, M ;
Barry, JC .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (02) :65-73
[30]   Comparison of pilocarpine-induced and stimulus-driven accommodation in phakic eyes [J].
Koeppl, C ;
Findl, O ;
Kriechbaum, K ;
Drexler, W .
EXPERIMENTAL EYE RESEARCH, 2005, 80 (06) :795-800