High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence?

被引:1
|
作者
Sousa, Pedro A. [1 ]
Puga, Luis [1 ]
Barra, Sergio [2 ]
Campos, Diana [1 ]
Antonio, Natalia [1 ,3 ]
Elvas, Luis [1 ]
Goncalves, Lino [1 ,3 ]
机构
[1] Coimbras Hosp & Univ Ctr, Cardiol Dept, Pacing & Electrophysiol Unit, Morada Praceta Prof Mota Pinto, P-3000075 Coimbra, Portugal
[2] Hosp Luz Arrabida, Cardiol Dept, Vn Gaia, Portugal
[3] Univ Coimbra, Fac Med, ICBR, Coimbra, Portugal
关键词
Ablation Index; High-Sensitivity Cardiac Troponin I; Ablation Effectiveness Quotient; Pulmonary Vein Isolation; Atrial Fibrillation; Arrhythmia Recurrence; RADIOFREQUENCY CATHETER ABLATION; ATRIAL-FIBRILLATION; RECONNECTION;
D O I
10.1007/s10840-022-01229-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence. Methods Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group]. Results Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI. Conclusions The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 37 条
  • [31] High Predictive Value of Adenosine Provocation in Predicting Atrial Fibrillation Recurrence After Pulmonary Vein Isolation With Visually Guided Laser Balloon Compared With Radiofrequency Ablation
    Ucer, Ekrem
    Fredersdorf, Sabine
    Seegers, Joachim
    Poschenrieder, Florian
    Hauck, Christian
    Maier, Lars
    Jungbauer, Carsten
    CIRCULATION JOURNAL, 2020, 84 (03) : 404 - 410
  • [32] High-Sensitivity C-Reactive Protein as a Predictor of Atrial Fibrillation Recurrence after Primary Circumferential Pulmonary Vein Isolation
    Liu, Jun
    Fang, Pi-Hua
    Dibs, Samer
    Hou, Yu
    Li, Xiao-Feng
    Zhang, Shu
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (04): : 398 - 406
  • [33] Procedural efficacy and safety of standardized, ablation index guided fixed 50 W high-power short-duration pulmonary vein isolation and substrate modification using the CLOSE protocol
    Francke, Alexander
    Taha, Nadja S.
    Scharfe, Frank
    Schoen, Steffen
    Wunderlich, Carsten
    Christoph, Marian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (09) : 2408 - 2417
  • [34] Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the 'CLOSE'-protocol
    Phlips, Thomas
    Taghji, Philippe
    El Haddad, Milad
    Wolf, Michael
    Knecht, Sebastien
    Vandekerckhove, Yves
    Tavernier, Rene
    Duytschaever, Mattias
    EUROPACE, 2018, 20 : F419 - F427
  • [35] Wide Antral Circumferential Re-Ablation for Recurrent Atrial Fibrillation after Prior Pulmonary Vein Isolation Guided by High-Density Mapping Increases Freedom from Atrial Arrhythmias
    Hartl, Stefan
    Makimoto, Hisaki
    Gerguri, Shqipe
    Clasen, Lukas
    Kluge, Sophia
    Brinkmeyer, Christoph
    Schmidt, Jan
    Rana, Obaida
    Kelm, Malte
    Bejinariu, Alexandru
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (15)
  • [36] Cryoballoon-Assisted Pulmonary Vein Isolation and Left Atrial Roof Ablation Using a Simplified Sedation Strategy without Esophageal Temperature Monitoring: No Notable Thermal Esophageal Lesions and Low Arrhythmia Recurrence Rates after 2 Years
    Erkapic, Damir
    Roussopoulos, Konstantinos
    Aleksic, Marko
    Soezener, Korkut
    Kostev, Karel
    Rosenbauer, Josef
    Sossalla, Samuel
    Guenduez, Dursun
    Labenz, Joachim
    Tanislav, Christian
    Weipert, Kay Felix
    DIAGNOSTICS, 2024, 14 (13)
  • [37] High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter
    Zeljkovic, Ivan
    Knecht, Sven
    Pavlovic, Nikola
    Celikyrut, Umut
    Spies, Florian
    Burri, Sarah
    Mannhart, Dominik
    Peterhans, Loris
    Reichlin, Tobias
    Schaer, Beat
    Osswald, Stefan
    Sticherling, Christian
    Kuhne, Michael
    OPEN HEART, 2019, 6 (01):