High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence?

被引:1
|
作者
Sousa, Pedro A. [1 ]
Puga, Luis [1 ]
Barra, Sergio [2 ]
Campos, Diana [1 ]
Antonio, Natalia [1 ,3 ]
Elvas, Luis [1 ]
Goncalves, Lino [1 ,3 ]
机构
[1] Coimbras Hosp & Univ Ctr, Cardiol Dept, Pacing & Electrophysiol Unit, Morada Praceta Prof Mota Pinto, P-3000075 Coimbra, Portugal
[2] Hosp Luz Arrabida, Cardiol Dept, Vn Gaia, Portugal
[3] Univ Coimbra, Fac Med, ICBR, Coimbra, Portugal
关键词
Ablation Index; High-Sensitivity Cardiac Troponin I; Ablation Effectiveness Quotient; Pulmonary Vein Isolation; Atrial Fibrillation; Arrhythmia Recurrence; RADIOFREQUENCY CATHETER ABLATION; ATRIAL-FIBRILLATION; RECONNECTION;
D O I
10.1007/s10840-022-01229-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence. Methods Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group]. Results Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI. Conclusions The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 37 条
  • [21] Two years after pulmonary vein isolation guided by ablation index-a multicenter study
    Sousa, Pedro A.
    Puga, Luis
    Adao, Luis
    Primo, Joao
    Khoueiry, Ziad
    Lebreiro, Ana
    Fonseca, Paulo
    Lagrange, Philippe
    Elvas, Luis
    Goncalves, Lino
    JOURNAL OF ARRHYTHMIA, 2022, 38 (03) : 346 - 352
  • [22] High-power short-duration ablation index-guided pulmonary vein isolation protocol using a single catheter
    Badertscher, Patrick
    Knecht, Sven
    Spies, Florian
    Vollmin, Gian
    Schaer, Beat
    Scharli, Nicolas
    Bosshard, Flurina
    Osswald, Stefan
    Sticherling, Christian
    Kuhne, Michael
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (03) : 633 - 642
  • [23] High-sensitivity cardiac Troponin T delta concentration after repeat pulmonary vein isolation
    Zeljkovic, Ivan
    Knecht, Sven
    Spies, Florian
    Reichlin, Tobias
    Schaer, Beat
    Osswald, Stefan
    Kuhne, Michael
    Sticherling, Christian
    BIOCHEMIA MEDICA, 2019, 29 (02)
  • [24] Predictors of pulmonary vein non-reconnection in the second procedure after ablation index-guided pulmonary vein isolation for atrial fibrillation and its impact on the outcome
    Okamatsu, Hideharu
    Okumura, Ken
    Onishi, Fumitaka
    Yoshimura, Akino
    Negishi, Kodai
    Tanaka, Yasuaki
    Tsurugi, Takuo
    Nakao, Koichi
    Sakamoto, Tomohiro
    Koyama, Junjiro
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (12) : 2452 - 2460
  • [25] Catheter ablation of atrial fibrillation using ablation index-guided high power (50 W) for pulmonary vein isolation with or without esophageal temperature probe (the AI-HP ES0 II)
    Chen, Shaojie
    Schmidt, Boris
    Seeger, Alexander
    Bordignon, Stefano
    Tohoku, Shota
    Willems, Franziska
    Urbanek, Lukas
    Throm, Christina
    Konstantinou, Athanasios
    Plank, Karin
    Hilbert, Max
    Zanchi, Simone
    Bianchini, Lorenzo
    Bologna, Fabrizio
    Tsianakas, Nikolaos
    Kreuzer, Claudia
    Chun, K. R. Julian
    HEART RHYTHM, 2020, 17 (11) : 1833 - 1840
  • [26] Clinical outcome of lesion size index-guided high-power radiofrequency catheter ablation for pulmonary vein isolation in patients with atrial fibrillation: 2-year follow-up
    Cai, Chi
    Wang, Jing
    Niu, Hong-Xia
    Chu, Jian-Min
    Hua, Wei
    Zhang, Shu
    Yao, Yan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (03) : 546 - 555
  • [27] Effect of pulmonary vein isolation on atrial fibrillation recurrence after ablation of paroxysmal supraventricular tachycardia in patients with high dispersion of atrial refractoriness
    Xu, Zhen-xing
    Zhong, Jing-quan
    Rong, Bing
    Yue, Xin
    Zheng, Zhao-tong
    Zhu, Qing
    Yi, Shao-lei
    Wang, Jun-tao
    Li, Man
    Zhang, Yun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 41 (02) : 169 - 175
  • [28] Effect of pulmonary vein isolation on atrial fibrillation recurrence after ablation of paroxysmal supraventricular tachycardia in patients with high dispersion of atrial refractoriness
    Zhen-xing Xu
    Jing-quan Zhong
    Bing Rong
    Xin Yue
    Zhao-tong Zheng
    Qing Zhu
    Shao-lei Yi
    Jun-tao Wang
    Man Li
    Yun Zhang
    Journal of Interventional Cardiac Electrophysiology, 2014, 41 : 169 - 175
  • [29] Tailored Target Ablation Index Guided Pulmonary Vein Isolation in Treating Paroxysmal Atrial Fibrillation: A Single Center Randomized Study in Asian Population (AI-Asian-I)
    Xiong, Qingsong
    Liao, Jia
    Chen, Weijie
    Xiao, Peilin
    Du, Huaan
    He, Qushuai
    Yin, Yuehui
    Ling, Zhiyu
    Chen, Shaojie
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [30] High-power short-duration ablation index–guided pulmonary vein isolation protocol using a single catheter
    Patrick Badertscher
    Sven Knecht
    Florian Spies
    Gian Völlmin
    Beat Schaer
    Nicolas Schärli
    Flurina Bosshard
    Stefan Osswald
    Christian Sticherling
    Michael Kühne
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 633 - 642