High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence?

被引:1
|
作者
Sousa, Pedro A. [1 ]
Puga, Luis [1 ]
Barra, Sergio [2 ]
Campos, Diana [1 ]
Antonio, Natalia [1 ,3 ]
Elvas, Luis [1 ]
Goncalves, Lino [1 ,3 ]
机构
[1] Coimbras Hosp & Univ Ctr, Cardiol Dept, Pacing & Electrophysiol Unit, Morada Praceta Prof Mota Pinto, P-3000075 Coimbra, Portugal
[2] Hosp Luz Arrabida, Cardiol Dept, Vn Gaia, Portugal
[3] Univ Coimbra, Fac Med, ICBR, Coimbra, Portugal
关键词
Ablation Index; High-Sensitivity Cardiac Troponin I; Ablation Effectiveness Quotient; Pulmonary Vein Isolation; Atrial Fibrillation; Arrhythmia Recurrence; RADIOFREQUENCY CATHETER ABLATION; ATRIAL-FIBRILLATION; RECONNECTION;
D O I
10.1007/s10840-022-01229-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence. Methods Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group]. Results Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI. Conclusions The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 37 条
  • [1] High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation—markers of arrhythmia recurrence?
    Pedro A. Sousa
    Luís Puga
    Sérgio Barra
    Diana Campos
    Natália António
    Luís Elvas
    Lino Gonçalves
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 115 - 121
  • [2] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Oikawa, Jun
    Saito, Daiki
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Nishinarita, Ryo
    Horiguchi, Ai
    Ishizue, Naruya
    Kishihara, Jun
    Niwano, Shinichi
    Ako, Junya
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 123 - 131
  • [3] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Shuhei Kobayashi
    Hidehira Fukaya
    Jun Oikawa
    Daiki Saito
    Tetsuro Sato
    Gen Matsuura
    Yuki Arakawa
    Yuki Shirakawa
    Ryo Nishinarita
    Ai Horiguchi
    Naruya Ishizue
    Jun Kishihara
    Shinichi Niwano
    Junya Ako
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 123 - 131
  • [4] Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation Patients The PRAISE Study Results
    Hussein, Ahmed
    Das, Moloy
    Riva, Stefania
    Morgan, Maureen
    Ronayne, Christina
    Sahni, Ankita
    Shaw, Matthew
    Todd, Derick
    Hall, Mark
    Modi, Simon
    Natale, Andrea
    Dello Russo, Antonio
    Snowdon, Richard
    Gupta, Dhiraj
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (09): : e006576
  • [5] Can Pre-Ablation Biomarkers Be Used to Predict Arrhythmia Recurrence after Ablation Index-Guided Atrial Fibrillation Ablation?
    Palma, Andreia
    Sousa, Pedro A.
    Saleiro, Carolina
    Adao, Luis
    Barra, Sergio
    Antonio, Natalia
    Primo, Joao
    Lebreiro, Ana
    Fonseca, Paulo
    Elvas, Luis
    Goncalves, Lino
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2024, 121 (04)
  • [6] Efficacy of ablation index-guided pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Jiang, Ruhong
    Chen, Minglong
    Fan, Jie
    Yi, Fu
    Tang, Anli
    Liu, Xingpeng
    Zhu, Wenqing
    Liu, Shaowen
    Huang, Xiaobo
    Liu, Qiang
    Ju, Weizhu
    Zhang, Xi
    Li, Jie
    He, Jiangui
    Shi, Liang
    Zhou, Genqing
    Wang, Yuegang
    Fu, Guosheng
    Jiang, Chenyang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (10): : 1186 - 1193
  • [7] Can Pre-Ablation Serum Biomarkers be Used to Predict Arrhythmia Recurrence after Ablation Index-Guided Atrial Fibrillation Ablation?
    Chokr, Muhieddine Omar
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2024, 121 (04)
  • [8] Ablation index-guided pulmonary vein isolation can reduce early recurrences of atrial tachyarrhythmias: a propensity score-matched analysis
    Yasumoto, Koji
    Egami, Yasuyuki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Tsuda, Masaki
    Okamoto, Naotaka
    Tanaka, Akihiro
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Shutta, Ryu
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 64 (02) : 479 - 487
  • [9] Ablation Index-guided point-by-point ablation versus Grid annotation-guided dragging for pulmonary vein isolation: A randomized controlled trial
    Mulder, Mark J.
    Kemme, Michiel J. B.
    Hopman, Luuk H. G. A.
    Hagen, Amaya M. D.
    van de Ven, Peter M.
    Hauer, Herbert A.
    Tahapary, Giovanni J. M.
    van Rossum, Albert C.
    Allaart, Cornelis P.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (01) : 64 - 72
  • [10] Revisiting exit block after entrance block: Investigation of ablation index-guided pulmonary vein isolation
    Nakashima, Takashi
    Nagase, Masaru
    Shibahara, Taro
    Ono, Daiju
    Yamada, Takehiro
    Tanabe, Gen
    Suzuki, Keita
    Yamaura, Makoto
    Ido, Takahisa
    Takahashi, Shigekiyo
    Okura, Hiroyuki
    Aoyama, Takuma
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (02): : 144 - 151