Development and validation of an inductively coupled plasma mass spectrometry (ICP-MS) method for the determination of cobalt, chromium, copper and nickel in oral mucosa cells

被引:56
作者
Martin-Camean, Ana [1 ]
Jos, Angeles [2 ]
Calleja, Ana [3 ]
Gil, Fernando [4 ]
Iglesias-Linares, Alejandro [1 ]
Solano, Enrique [1 ]
Camean, Ana M. [2 ]
机构
[1] Univ Seville, Dept Stomatol, Sch Dent, E-41009 Seville, Spain
[2] Univ Seville, Area Toxicol, Fac Pharm, E-41009 Seville, Spain
[3] Univ Seville, Invest Technol & Innovat Ctr, E-41009 Seville, Spain
[4] Univ Granada, Sch Med, Dept Legal Med & Toxicol, E-18071 Granada, Spain
关键词
Metals; Oral mucosa cells; ICP-MS; Orthodontic appliances; FIXED ORTHODONTIC APPLIANCES; METAL RELEASE; IN-VIVO; OXIDATIVE STRESS; SALIVARY NICKEL;
D O I
10.1016/j.microc.2013.12.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The oral cavity is an ideal environment for the corrosion of fixed orthodontic appliances, leading to the release of metal ions that, eventually, could derive in adverse effects. Therefore, it is necessary to evaluate the biocompatibility of these materials for patient's safety. In vivo, oral mucosa cells are a valuable sample for this aim, however, analytical methods to quantify the liberation of metal ions are very scarce. Thus, the purpose of this work is to optimize and validate a sample preparation procedure to determine cobalt (Co), chromium (Cr), copper (Cu), and nickel (Ni) in oral mucosa cells in patients with and without orthodontic appliances, based on the extraction and digestion of the samples and quantification of the elements by inductively coupled plasma mass spectrometry (ICP-MS). The method has been suitably validated: the regression equation was calculated from standards prepared in the same matrix without oral mucosa cells and the linear range was 2.0-100.0 ng mL(-1) for all elements. Limits of detection were 0.10, 0.38, 0.49 and 0.67 ng mL(-1) and limits of quantification were 0.20, 1.13, 0.98, and 1.81 ng mL(-1) for Co, Cr, Cu, and Ni, respectively. The recovery percentages (%) obtained ranged between 104 and 109 for Co, 103-107 for Cr, 106-113 for Cu and 84-110 for Ni. Intermediate precision (RSD%) data obtained were also adequate. The present method proved to be robust for the three factors considered: heating time, volume of deionized water, and volume of PlasmaPure 65% HNO3 used to dilute the samples. Thus, the proposed method passed in a satisfactory way the validation standards considered and could be used to evaluate in vivo the metal ion release in oral mucosa cells from orthodontic patients. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 39 条
[1]   In vivo study of metal content of oral mucosa cells in patients with and without fixed orthodontic appliances [J].
Amini, F. ;
Borzabadi Farahani, A. ;
Jafari, A. ;
Rabbani, M. .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2008, 11 (01) :51-56
[2]  
[Anonymous], 2005, ICH HARM TRIP GUID V
[3]  
[Anonymous], GUID DRINK WAT QUAL
[4]  
[Anonymous], MON EV CARC RISK CHE
[5]  
AOAC International, 1998, AOAC PEER VER METH P
[6]  
Baars AJ, 2001, 711701025 RIVM DUTCH
[7]   BIODEGRADATION OF ORTHODONTIC APPLIANCES .1. BIODEGRADATION OF NICKEL AND CHROMIUM INVITRO [J].
BARRETT, RD ;
BISHARA, SE ;
QUINN, JK .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1993, 103 (01) :8-14
[8]  
Burrows D, 1986, Int Dent J, V36, P30
[9]   CYTOTOXICITY OF EXPERIMENTAL CASTING ALLOYS EVALUATED BY CELL-CULTURE TESTS [J].
CRAIG, RG ;
HANKS, CT .
JOURNAL OF DENTAL RESEARCH, 1990, 69 (08) :1539-1542
[10]   ALLERGIC REACTION TO ORTHODONTIC WIRE - REPORT OF CASE [J].
DUNLAP, CL ;
VINCENT, SK ;
BARKER, BF .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1989, 118 (04) :449-450