Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals

被引:0
作者
Nakamura, Keisuke [1 ,2 ]
Ohira, Masayoshi [3 ]
Yokokawa, Yoshiharu [3 ]
Nagasawa, Yuya [1 ]
机构
[1] Matsumoto City Hosp, Dept Rehabil, Matsumoto, Nagano 3901401, Japan
[2] Shinshu Univ, Grad Sch Med, Dept Hlth Sci, Matsumoto, Nagano 390, Japan
[3] Shinshu Univ, Sch Hlth Sci, Dept Phys Therapy, Matsumoto, Nagano 390, Japan
关键词
Sit-to-stand; cycle ergometer; anaerobic threshold; correlations; reproducibility; validity; 6-MINUTE WALK TEST; OXYGEN-UPTAKE; CARDIAC REHABILITATION; PERCEIVED EXERTION; ARM; RELIABILITY; CONSUMPTION; FREQUENCY;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 +/- 1.9 mL.min(-1).kg(-1)) and the CE test (18.4 +/- 1.8 mL.min(-1).kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 +/- 1.8 mL.min(-1).kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 +/- 10 bpm) and the CE test (126 +/- 13 bpm) were significantly higher than those during the ISTS without arm support (119 +/- 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.
引用
收藏
页码:708 / 715
页数:8
相关论文
共 50 条
  • [41] Five times sit-to-stand test for ambulatory individuals with spinal cord injury: a psychometric study on the effects of arm placements
    Khuna, Lalita
    Thaweewannakij, Thiwabhorn
    Wattanapan, Pattra
    Amatachaya, Pipatana
    Amatachaya, Sugalya
    SPINAL CORD, 2020, 58 (03) : 356 - 364
  • [42] Validity of the 30-Second Sit-to-Stand test as a measure of lower extremity function in persons with multiple sclerosis: Preliminary evidence
    Zheng, Peixuan
    Huynh, Trinh L. T.
    Jones, C. Danielle
    Feasel, Corey D.
    Jeng, Brenda
    Motl, Robert W.
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2023, 71
  • [43] One minute sit-to-stand test is an alternative to 6MWT to measure functional exercise performance in COPD patients
    Reychler, Gregory
    Boucard, Eliott
    Peran, Loic
    Pichon, Romain
    Le Ber-Moy, Catherine
    Ouksel, Hakima
    Liistro, Giuseppe
    Chambellan, Arnaud
    Beaumont, Marc
    CLINICAL RESPIRATORY JOURNAL, 2018, 12 (03) : 1247 - 1256
  • [44] The Reliability and Validity of the Timed Up & Go Test and the 30-S Sit-To-Stand Test Performed via Tele-Assessment in Ambulatory Patients with Stroke
    Tutuneken, Yunus Emre
    Cirak, Yasemin Buran
    Kardes, Kubra
    Isikci, Burcu
    Binbuga, Ramazan
    Cetrefli, Emre
    Sarili, Mehmet
    Oz, Recep Tayyip
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2024, 28 (03) : 236 - 243
  • [45] Reference values and validation of the 1-minute sit-to-stand test in healthy 5-16-year-old youth: a cross-sectional study
    Haile, Sarah R.
    Fuhner, Thea
    Granacher, Urs
    Stocker, Julien
    Radtke, Thomas
    Kriemler, Susi
    BMJ OPEN, 2021, 11 (05):
  • [46] A Method for the Evaluation of Anaerobic Threshold Based on Heart Rate Dynamics during Incremental Exercise Test and Recovery
    Kozlov A.V.
    Yakushkin A.V.
    Andreev R.S.
    Vavaev A.V.
    Yurikov R.V.
    Sonkin V.D.
    Human Physiology, 2019, 45 (2) : 180 - 187
  • [47] Responsiveness and minimal clinically important difference of the five times sit-to-stand test in ambulatory individuals with spinal cord injury: A six-month prospective cohort study
    Amatachaya, Sugalya
    Khuna, Lalita
    Thaweewannakij, Thiwabhorn
    CLINICAL REHABILITATION, 2023, 37 (01) : 109 - 118
  • [48] The 2-Minutes Walking Test Is Not Correlated with Aerobic Fitness Indices but with the 5-Times Sit-to-Stand Test Performance in Apparently Healthy Older Adults
    Gil-Calvo, Marina
    de Paz, Jose Antonio
    Herrero-Molleda, Alba
    Zecchin, Arthur
    Gomez-Alonso, Maria Teresa
    Alonso-Cortes, Beatriz
    Boullosa, Daniel
    GERIATRICS, 2024, 9 (02)
  • [49] EMG and kinematics analysis of the trunk and lower extremity during the sit-to-stand task while wearing shoes with different heel heights in healthy young women
    Kim, Min H.
    Yi, Chung H.
    Yoo, Won G.
    Choi, Bo R.
    HUMAN MOVEMENT SCIENCE, 2011, 30 (03) : 596 - 605
  • [50] Exercise capacity assessed with the one-minute sit-to-stand test (1-min STST) and echocardiographic findings in patients with heart failure with preserved ejection fraction (HFpEF)
    Kronberger, Christina
    Mousavi, Roya Anahita
    Ozturk, Begum
    Dachs, Theresa-Marie
    Rettl, Rene
    Camuz-Ligios, Luciana
    Litschauer, Brigitte
    Badr-Eslam, Roza
    HEART & LUNG, 2022, 55 : 134 - 139