摘要
Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 +/- 1.9 mL.min(-1).kg(-1)) and the CE test (18.4 +/- 1.8 mL.min(-1).kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 +/- 1.8 mL.min(-1).kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 +/- 10 bpm) and the CE test (126 +/- 13 bpm) were significantly higher than those during the ISTS without arm support (119 +/- 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.
引用
收藏
页码:708 / 715
页数:8
相关论文
共 50 条
  • [41] Perception of Weight-Bearing Distribution During Sit-to-Stand Tasks in Hemiparetic and Healthy Individuals
    Briere, Anabele
    Lauziere, Selena
    Gravel, Denis
    Nadeau, Sylvie
    STROKE, 2010, 41 (08) : 1704 - 1708
  • [42] Assisted Spatial Sit-to-Stand Prediction-Part 1: Virtual Healthy Elderly Individuals
    Yang, James
    Ozsoy, Burak
    JOURNAL OF COMPUTING AND INFORMATION SCIENCE IN ENGINEERING, 2021, 21 (04)
  • [43] Weight-bearing distribution at the lower limbs during the five-repetition sit-to-stand test in hemiparetic and healthy individuals
    Briere, A.
    Lauziere, S.
    Nadeau, S.
    STROKE, 2011, 42 (11) : E608 - E608
  • [44] Five-Repetition Sit-to-Stand Test Performance in Healthy Individuals : Reference Values and Predictors From 2 Prospective Cohorts
    Klukowska, Anita M.
    Staartjes, Victor E.
    Vandertop, W. Peter
    Schroder, Marc L.
    NEUROSPINE, 2021, 18 (04) : 760 - +
  • [45] Reliability and validity of the five-repetition sit-to-stand test in adult kidney transplant recipients
    Huang, Katherin S.
    O'Connor, Ellen
    Tuffnell, Rachel
    Lindup, Herolin
    Macdougall, Iain C.
    Greenwood, Sharlene A.
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2018, 25 (04): : 158 - 166
  • [46] Reproducibility and safety of the 30" sit to stand test in individuals with obesity and cardiovascular risk factors
    Lazaro-Martinez, Samuel
    De Jesus Orueta-Jimenez, Teresa
    Ivan Arias-Vazquez, Pedro
    Giannina Castillo-Avila, Rosa
    Alfonso Tovilla-Zarate, Carlos
    Del Carmen Hernandez-Gil, Karen
    Quezada-Gonzalez, Ricardo
    Loeza-Magana, Pavel
    Lilia Lopez-Narvaez, Maria
    Eduardo Garcia-Gonzalez, Luis
    OBESITY RESEARCH & CLINICAL PRACTICE, 2022, 16 (06) : 533 - 535
  • [47] FIVE-REPETITION SIT-TO-STAND TEST: RELIABILITY, VALIDITY AND RESPONSE TO PULMONARY REHABILITATION IN COPD
    Jones, S. E.
    Kon, S. S. C.
    Canavan, J. L.
    Clark, A. L.
    Patel, M. S.
    Dilaver, D.
    Peasey, M.
    Ng, M. G. S.
    Polkey, M. I.
    Man, W. D-C
    THORAX, 2012, 67 : A53 - A53
  • [48] Assessment of the feasibility of 1-min sit-to-stand test in evaluating functional exercise capacity in interstitial lung disease patients
    Singh, Ravi
    Aggarwal, Deepak
    Dutta, Kashish
    Jaggi, Surabhi
    Sodhi, Mandeep Kaur
    Saini, Varinder
    JOURNAL OF EXERCISE REHABILITATION, 2023, 19 (06) : 363 - 369
  • [49] Validity and reliability of incremental test to determine the anaerobic threshold in swimming rats
    Beck, Wladimir R.
    Campesan, Yuri S.
    Gobatto, Claudio A.
    INTERNATIONAL JOURNAL OF APPLIED EXERCISE PHYSIOLOGY, 2015, 4 (01): : 25 - 33
  • [50] The role of thigh muscular efforts in limiting sit-to-stand capacity in healthy young and older adults
    Bryanton, Megan
    Bilodeau, Martin
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2017, 29 (06) : 1211 - 1219