Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals

被引:0
|
作者
Nakamura, Keisuke [1 ,2 ]
Ohira, Masayoshi [3 ]
Yokokawa, Yoshiharu [3 ]
Nagasawa, Yuya [1 ]
机构
[1] Matsumoto City Hosp, Dept Rehabil, Matsumoto, Nagano 3901401, Japan
[2] Shinshu Univ, Grad Sch Med, Dept Hlth Sci, Matsumoto, Nagano 390, Japan
[3] Shinshu Univ, Sch Hlth Sci, Dept Phys Therapy, Matsumoto, Nagano 390, Japan
关键词
Sit-to-stand; cycle ergometer; anaerobic threshold; correlations; reproducibility; validity; 6-MINUTE WALK TEST; OXYGEN-UPTAKE; CARDIAC REHABILITATION; PERCEIVED EXERTION; ARM; RELIABILITY; CONSUMPTION; FREQUENCY;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 +/- 1.9 mL.min(-1).kg(-1)) and the CE test (18.4 +/- 1.8 mL.min(-1).kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 +/- 1.8 mL.min(-1).kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 +/- 10 bpm) and the CE test (126 +/- 13 bpm) were significantly higher than those during the ISTS without arm support (119 +/- 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.
引用
收藏
页码:708 / 715
页数:8
相关论文
共 50 条
  • [31] Reliability and validity of the five-repetition sit-to-stand test for children with cerebral palsy
    Wang, Tze-Hsuan
    Liao, Hua-Fang
    Peng, Yi-Chun
    CLINICAL REHABILITATION, 2012, 26 (07) : 664 - 671
  • [32] Effect of progressive bridging exercise on weight-bearing during the extension phase of sit-to-stand, and on sit-to-stand ability in individuals with stroke: A randomised controlled trial
    Pankheaw, Thitinat
    Hiengkaew, Vimonwan
    Bovonsunthonchai, Sunee
    Tretriluxana, Jarugool
    CLINICAL REHABILITATION, 2022, 36 (11) : 1463 - 1475
  • [33] Biomechanical Analysis of Gait and Sit-to-Stand Patterns Using a Specially Made Knee Supporter in Healthy Young and Elderly Individuals
    Abe, Daijiro
    Hotta, Norio
    Fukuoka, Yoshiyuki
    Ohta, Yoko
    Hamasaki, Keiko
    JOURNAL OF PHYSIOLOGICAL ANTHROPOLOGY, 2010, 29 (02) : 65 - 70
  • [34] 5-Repetition Sit-to-Stand Test in Subjects With Chronic Stroke: Reliability and Validity
    Mong, Yiqin
    Teo, Tilda W.
    Ng, Shamay S.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (03): : 407 - 413
  • [35] Timing of ankle motion and trunk velocity during sit-to-stand in healthy young subjects
    Abdolrahmani, A.
    Yonetsu, R.
    ANNALS OF PHYSICAL AND REHABILITATION MEDICINE, 2016, 59 (02) : 130 - 132
  • [36] Effect analysis of seat height on sit-to-stand movement stability in healthy young adults
    Yang, Shuo
    Jia, Peng
    Zhao, Na
    Zhang, Shouwei
    Xue, Qiang
    INTERNATIONAL JOURNAL OF INTELLIGENT ROBOTICS AND APPLICATIONS, 2024, 8 (04) : 1028 - 1037
  • [37] Sagittal spine and lower limb movement during sit-to-stand in healthy young subjects
    Tully, EA
    Fotoohabadi, MR
    Galea, MP
    GAIT & POSTURE, 2005, 22 (04) : 338 - 345
  • [38] Reliability and validity of a smartphone-based application for the quantification of the sit-to-stand movement in healthy seniors
    Cerrito, Adrien
    Bichsel, Lukas
    Radlinger, Lorenz
    Schmid, Stefan
    GAIT & POSTURE, 2015, 41 (02) : 409 - 413
  • [39] Kinetic and Kinematic Comparison of Sit-To-Stand Movement between Healthy Young and Elderly Subjects
    Kim, Du-Hwan
    Park, Sung-Min
    Jeon, Doyoung
    Sung, Duk Hyun
    ANNALS OF REHABILITATION MEDICINE-ARM, 2006, 30 (04): : 385 - 391
  • [40] A SIT-TO-STAND TEST IS USEFUL TO ASSESS EXERCISE OXYGENATION IN PATIENTS WITH INTERSTITIAL LUNG DISEASE
    Visser, S.
    Piggott, A.
    Spencer, L.
    Alison, J.
    Webster, S.
    Troy, L.
    Hayen, A.
    Torzillo, P.
    Corte, P.
    Corte, T.
    RESPIROLOGY, 2017, 22 : 29 - 29