Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals

被引:0
作者
Nakamura, Keisuke [1 ,2 ]
Ohira, Masayoshi [3 ]
Yokokawa, Yoshiharu [3 ]
Nagasawa, Yuya [1 ]
机构
[1] Matsumoto City Hosp, Dept Rehabil, Matsumoto, Nagano 3901401, Japan
[2] Shinshu Univ, Grad Sch Med, Dept Hlth Sci, Matsumoto, Nagano 390, Japan
[3] Shinshu Univ, Sch Hlth Sci, Dept Phys Therapy, Matsumoto, Nagano 390, Japan
关键词
Sit-to-stand; cycle ergometer; anaerobic threshold; correlations; reproducibility; validity; 6-MINUTE WALK TEST; OXYGEN-UPTAKE; CARDIAC REHABILITATION; PERCEIVED EXERTION; ARM; RELIABILITY; CONSUMPTION; FREQUENCY;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 +/- 1.9 mL.min(-1).kg(-1)) and the CE test (18.4 +/- 1.8 mL.min(-1).kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 +/- 1.8 mL.min(-1).kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 +/- 10 bpm) and the CE test (126 +/- 13 bpm) were significantly higher than those during the ISTS without arm support (119 +/- 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.
引用
收藏
页码:708 / 715
页数:8
相关论文
共 50 条
  • [11] The Relationship between Sit-to-stand Frequency and Anaerobic Threshold Determined by Cycle Ergometer
    Kamimura, Satomi
    Akiyama, Sumikazu
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (01) : 53 - 55
  • [12] Effect of progressive bridging exercise on weight-bearing during the extension phase of sit-to-stand, and on sit-to-stand ability in individuals with stroke: A randomised controlled trial
    Pankheaw, Thitinat
    Hiengkaew, Vimonwan
    Bovonsunthonchai, Sunee
    Tretriluxana, Jarugool
    CLINICAL REHABILITATION, 2022, 36 (11) : 1463 - 1475
  • [13] Clinical measurement of sit-to-stand performance in people with balance disorders: Validity of data for the five-times-sit-to-stand test
    Whitney, SL
    Wrisley, DM
    Marchetti, GF
    Gee, MA
    Redfern, MS
    Furman, JM
    PHYSICAL THERAPY, 2005, 85 (10): : 1034 - 1045
  • [14] Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults
    Jerez-Mayorga, Daniel
    Huerta-Ojeda, Alvaro
    Javier Chirosa-Rios, Luis
    Guede-Rojas, Francisco
    Guzman-Guzman, Iris Paola
    Intelangelo, Leonardo
    Miranda-Fuentes, Claudia
    Delgado-Floody, Pedro
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [15] Sit-to-stand test in children with bronchiectasis: Does it measure functional exercise capacity?
    Zeren, Melih
    Gurses, Hulya Nilgun
    Kulli, Hilal Denizoglu
    Ucgun, Hikmet
    Cakir, Erkan
    HEART & LUNG, 2020, 49 (06): : 796 - 802
  • [16] Validity and variability of the 5-repetition sit-to-stand test in patients with multiple sclerosis
    Moller, Andreas Buch
    Bibby, Bo Martin
    Skjerbaek, Anders Guldhammer
    Jensen, Ellen
    Sorensen, Henrik
    Stenager, Egon
    Dalgas, Ulrik
    DISABILITY AND REHABILITATION, 2012, 34 (26) : 2251 - 2258
  • [17] Effect analysis of seat height on sit-to-stand movement stability in healthy young adults
    Yang, Shuo
    Jia, Peng
    Zhao, Na
    Zhang, Shouwei
    Xue, Qiang
    INTERNATIONAL JOURNAL OF INTELLIGENT ROBOTICS AND APPLICATIONS, 2024, 8 (04) : 1028 - 1037
  • [18] Sagittal spine and lower limb movement during sit-to-stand in healthy young subjects
    Tully, EA
    Fotoohabadi, MR
    Galea, MP
    GAIT & POSTURE, 2005, 22 (04) : 338 - 345
  • [19] Kinetic and Kinematic Comparison of Sit-To-Stand Movement between Healthy Young and Elderly Subjects
    Kim, Du-Hwan
    Park, Sung-Min
    Jeon, Doyoung
    Sung, Duk Hyun
    ANNALS OF REHABILITATION MEDICINE-ARM, 2006, 30 (04): : 385 - 391
  • [20] Digital Analysis of Sit-to-Stand in Masters Athletes, Healthy Old People, and Young Adults Using a Depth Sensor
    Leightley, Daniel
    Yap, Moi Hoon
    HEALTHCARE, 2018, 6 (01)