Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals

被引:0
|
作者
Nakamura, Keisuke [1 ,2 ]
Ohira, Masayoshi [3 ]
Yokokawa, Yoshiharu [3 ]
Nagasawa, Yuya [1 ]
机构
[1] Matsumoto City Hosp, Dept Rehabil, Matsumoto, Nagano 3901401, Japan
[2] Shinshu Univ, Grad Sch Med, Dept Hlth Sci, Matsumoto, Nagano 390, Japan
[3] Shinshu Univ, Sch Hlth Sci, Dept Phys Therapy, Matsumoto, Nagano 390, Japan
关键词
Sit-to-stand; cycle ergometer; anaerobic threshold; correlations; reproducibility; validity; 6-MINUTE WALK TEST; OXYGEN-UPTAKE; CARDIAC REHABILITATION; PERCEIVED EXERTION; ARM; RELIABILITY; CONSUMPTION; FREQUENCY;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 +/- 1.9 mL.min(-1).kg(-1)) and the CE test (18.4 +/- 1.8 mL.min(-1).kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 +/- 1.8 mL.min(-1).kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 +/- 10 bpm) and the CE test (126 +/- 13 bpm) were significantly higher than those during the ISTS without arm support (119 +/- 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.
引用
收藏
页码:708 / 715
页数:8
相关论文
共 50 条
  • [11] A study of the reliability and construct validity of the 1-minute sit-to-stand test for individuals with systemic sclerosis
    Laursen, Jakob
    Christensen, Amalie
    Egsgaard, Simon
    Sondergaard, Klaus
    Mechlenburg, Inger
    Brincks, John
    PHYSIOTHERAPY THEORY AND PRACTICE, 2024,
  • [12] The relationship of sit-to-stand tests with 6-minute walk test in healthy young adults
    Gurses, Hulya Nilgun
    Zeren, Melih
    Kulli, Hilal Denizoglu
    Durgut, Elif
    MEDICINE, 2018, 97 (01)
  • [13] The Relationship between Sit-to-stand Frequency and Anaerobic Threshold Determined by Cycle Ergometer
    Kamimura, Satomi
    Akiyama, Sumikazu
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (01) : 53 - 55
  • [14] PERCEPTION OF WEIGHT-BEARING DISTRIBUTION DURING SIT-TO-STAND TASK IN HEALTHY YOUNG AND ELDERLY INDIVIDUALS
    Lauziere, Selena
    Briere, Anabele
    Nadeau, Sylvie
    PERCEPTUAL AND MOTOR SKILLS, 2010, 111 (01) : 187 - 198
  • [15] Comparison of sit-to-stand test and sixminute walk test in asthmatic and healthy children
    Kahraman, Buse Ozcan
    Ozsoy, Ismail
    Tanriverdi, Aylin
    Polat, Karya
    Papurcu, Asli
    Sezgin, Nazenin Hande
    Acar, Serap
    Atakul, Gizem
    Uzuner, Nevin
    Asilsoy, Suna
    Karaman, Ozkan
    Savci, Sema
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [16] Rollator usage lets young individuals switch movement strategies in sit-to-stand and stand-to-sit tasks
    Michael Herzog
    Frieder C. Krafft
    Bernd J. Stetter
    Andrea d’Avella
    Lizeth H. Sloot
    Thorsten Stein
    Scientific Reports, 13
  • [17] Rollator usage lets young individuals switch movement strategies in sit-to-stand and stand-to-sit tasks
    Herzog, Michael
    Krafft, Frieder C.
    Stetter, Bernd J.
    d'Avella, Andrea
    Sloot, Lizeth H.
    Stein, Thorsten
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [18] Modified 30-Second Sit-to-Stand Test: Reliability and Validity in Older Adults Unable to Complete Traditional Sit-to-Stand Testing
    McAllister, Linda S.
    Palombaro, Kerstin M.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2020, 43 (03) : 153 - 158
  • [19] Is the "Sit-to-stand test" a good tool for evaluating oxygen desaturation in COPD?
    Fernandes, Ana Luisa
    Camilo, Zita
    Luis, Graciete
    Neves, Ines
    Ferreira, Jorge
    Simao, Paula
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [20] Postural stability with exhaustive repetitive sit-to-stand exercise in young adults
    Bryanton, Megan A.
    Bilodeau, Martin
    HUMAN MOVEMENT SCIENCE, 2016, 49 : 47 - 53