Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals

被引:0
作者
Nakamura, Keisuke [1 ,2 ]
Ohira, Masayoshi [3 ]
Yokokawa, Yoshiharu [3 ]
Nagasawa, Yuya [1 ]
机构
[1] Matsumoto City Hosp, Dept Rehabil, Matsumoto, Nagano 3901401, Japan
[2] Shinshu Univ, Grad Sch Med, Dept Hlth Sci, Matsumoto, Nagano 390, Japan
[3] Shinshu Univ, Sch Hlth Sci, Dept Phys Therapy, Matsumoto, Nagano 390, Japan
关键词
Sit-to-stand; cycle ergometer; anaerobic threshold; correlations; reproducibility; validity; 6-MINUTE WALK TEST; OXYGEN-UPTAKE; CARDIAC REHABILITATION; PERCEIVED EXERTION; ARM; RELIABILITY; CONSUMPTION; FREQUENCY;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 +/- 1.9 mL.min(-1).kg(-1)) and the CE test (18.4 +/- 1.8 mL.min(-1).kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 +/- 1.8 mL.min(-1).kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 +/- 10 bpm) and the CE test (126 +/- 13 bpm) were significantly higher than those during the ISTS without arm support (119 +/- 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.
引用
收藏
页码:708 / 715
页数:8
相关论文
共 50 条
  • [1] Development of an Incremental Sit-to-Stand Exercise for Aerobic Fitness Evaluation
    Nakamura, Keisuke
    Nagasawa, Yuya
    Sawaki, Shoji
    Yokokawa, Yoshiharu
    Ohira, Masayoshi
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2017, 38 (11) : 827 - 832
  • [2] Effect of Different Seat Heights during an Incremental Sit-To-Stand Exercise Test on Peak Oxygen Uptake in Young, Healthy Women
    Nakamura, Keisuke
    Nagasawa, Yuya
    Sawaki, Shoji
    Yokokawa, Yoshiharu
    Ohira, Masayoshi
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2016, 15 (03) : 410 - 416
  • [3] An Incremental Sit-to-Stand Exercise for Evaluating Physical Capacity in Older Patients with Type 2 Diabetes
    Nakamura, Keisuke
    Nagasawa, Yuya
    Sawaki, Shoji
    Yokokawa, Yoshiharu
    Ohira, Masayoshi
    Sato, Yoshihiko
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2019, 249 (04) : 241 - 248
  • [4] Reliability and validity of sit-to-stand test protocols in patients with coronary artery disease
    Wang, Zheng
    Yan, Jianhua
    Meng, Shu
    Li, Jiajia
    Yu, Yi
    Zhang, Tingting
    Tsang, Raymond C. C.
    El-Ansary, Doa
    Han, Jia
    Jones, Alice Y. M.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [5] Three dimensional unassisted sit-to-stand prediction for virtual healthy young and elderly individuals
    Yang, James
    Ozsoy, Burak
    MULTIBODY SYSTEM DYNAMICS, 2020, 49 (01) : 33 - 52
  • [6] Three dimensional unassisted sit-to-stand prediction for virtual healthy young and elderly individuals
    James Yang
    Burak Ozsoy
    Multibody System Dynamics, 2020, 49 : 33 - 52
  • [7] Reliability and validity of the five-repetition sit-to-stand test for children with cerebral palsy
    Wang, Tze-Hsuan
    Liao, Hua-Fang
    Peng, Yi-Chun
    CLINICAL REHABILITATION, 2012, 26 (07) : 664 - 671
  • [8] Modified 30-Second Sit-to-Stand Test: Reliability and Validity in Older Adults Unable to Complete Traditional Sit-to-Stand Testing
    McAllister, Linda S.
    Palombaro, Kerstin M.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2020, 43 (03) : 153 - 158
  • [9] Five-Repetition Sit-to-Stand Test Performance in Healthy Individuals : Reference Values and Predictors From 2 Prospective Cohorts
    Klukowska, Anita M.
    Staartjes, Victor E.
    Vandertop, W. Peter
    Schroder, Marc L.
    NEUROSPINE, 2021, 18 (04) : 760 - +
  • [10] A study of the reliability and construct validity of the 1-minute sit-to-stand test for individuals with systemic sclerosis
    Laursen, Jakob
    Christensen, Amalie
    Egsgaard, Simon
    Sondergaard, Klaus
    Mechlenburg, Inger
    Brincks, John
    PHYSIOTHERAPY THEORY AND PRACTICE, 2024,