Fabrication of sharp silicon hollow microneedles by deep-reactive ion etching towards minimally invasive diagnostics

被引:156
作者
Li, Yan [1 ,2 ]
Zhang, Hang [1 ]
Yang, Ruifeng [1 ]
Laffitte, Yohan [2 ]
Schmill, Ulises [2 ]
Hu, Wenhan [1 ]
Kaddoura, Moufeed [2 ]
Blondeel, Eric J. M. [2 ]
Cui, Bo [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, 200 Univ Ave West, Waterloo, ON N2L 3G1, Canada
[2] ExVivo Labs Inc, 3 Regina St North, Waterloo, ON N2J 2Z7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
OF-PLANE MICRONEEDLES; ASPECT-RATIO; INTERSTITIAL FLUID; SKIN; ARRAY; PREDICTION; CHEMISTRY; TRANSPORT;
D O I
10.1038/s41378-019-0077-y
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Microneedle technologies have the potential for expanding the capabilities of wearable health monitoring from physiology to biochemistry. This paper presents the fabrication of silicon hollow microneedles by a deep-reactive ion etching (DRIE) process, with the aim of exploring the feasibility of microneedle-based in-vivo monitoring of biomarkers in skin fluid. Such devices shall have the ability to allow the sensing elements to be integrated either within the needle borehole or on the backside of the device, relying on capillary filling of the borehole with dermal interstitial fluid (ISF) for transporting clinically relevant biomarkers to the sensor sites. The modified DRIE process was utilized for the anisotropic etching of circular holes with diameters as small as 30 mu m to a depth of >300 mu m by enhancing ion bombardment to efficiently remove the fluorocarbon passivation polymer. Afterward, isotropic wet and/or dry etching was utilized to sharpen the needle due to faster etching at the pillar top, achieving tip radii as small as 5 mu m. Such sharp microneedles have been demonstrated to be sufficiently robust to penetrate porcine skin without needing any aids such as an impact-insertion applicator, with the needles remaining mechanically intact after repetitive penetrations. The capillary filling of DRIE-etched through-wafer holes with water has also been demonstrated, showing the feasibility of use to transport the analyte to the target sites.
引用
收藏
页数:11
相关论文
共 54 条
[1]   An advanced reactive ion etching process for very high aspect-ratio sub-micron wide trenches in silicon [J].
Abdolvand, Reza ;
Ayazi, Farrokh .
SENSORS AND ACTUATORS A-PHYSICAL, 2008, 144 (01) :109-116
[2]  
[Anonymous], PHARM DESIGN MANUFAC
[3]  
[Anonymous], 2016, SCI REP, DOI DOI 10.1038/SREP29075
[4]   Single-unit neural recording with active microelectrode arrays [J].
Bai, Q ;
Wise, KD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (08) :911-920
[5]   Proteomic Characterization of Dermal Interstitial Fluid Extracted Using a Novel Microneedle-Assisted Technique [J].
Bao Quoc Tran ;
Miller, Philip R. ;
Taylor, Robert M. ;
Boyd, Gabrielle ;
Mach, Phillip M. ;
Rosenzweig, C. Nicole ;
Baca, Justin T. ;
Polsky, Ronen ;
Glaros, Trevor .
JOURNAL OF PROTEOME RESEARCH, 2018, 17 (01) :479-485
[6]  
Benias PC, 2018, SCI REP-UK, V8, DOI [10.1038/s41598-018-25732-x, 10.1038/s41598-018-23062-6]
[7]   A wafer-scale etching technique for high aspect ratio implantable MEMS structures [J].
Bhandari, R. ;
Negi, S. ;
Rieth, L. ;
Solzbacher, F. .
SENSORS AND ACTUATORS A-PHYSICAL, 2010, 162 (01) :130-136
[8]   Advanced time-multiplexed plasma etching of high aspect ratio silicon structures [J].
Blauw, MA ;
Craciun, G ;
Sloof, WG ;
French, PJ ;
van der Drift, E .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2002, 20 (06) :3106-3110
[9]   A SILICON-BASED, 3-DIMENSIONAL NEURAL INTERFACE - MANUFACTURING PROCESSES FOR AN INTRACORTICAL ELECTRODE ARRAY [J].
CAMPBELL, PK ;
JONES, KE ;
HUBER, RJ ;
HORCH, KW ;
NORMANN, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) :758-768
[10]   Effect of microneedles shape on skin penetration and minimally invasive continuous glucose monitoring in vivo [J].
Chua, Beelee ;
Desai, Shashi P. ;
Tierney, Michael J. ;
Tamada, Janet A. ;
Jina, Arvind N. .
SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 :373-381