Failure analysis of a welded stainless-steel piping system with premature pitting

被引:14
作者
Bedoya-Zapata, Alvaro Diego [1 ]
Franco-Rendon, Carlos Mauricio [1 ]
Leon-Henao, Henry [1 ]
Santa, Juan Felipe [1 ,2 ]
Barrada, Jorge Enrique Giraldo [1 ]
机构
[1] Univ Nacl Colombia, Grp Soldadura, Sede Medellin, Medellin, Colombia
[2] Inst Tecnol Metropolitano, Grp Invest Mat Avanzados & Energia MATyER, Medellin, Colombia
关键词
Microbiologically-influenced corrosion; Hydrostatic testing; Austenitic stainless steel; Welding; Heat tint; Pitting;
D O I
10.1016/j.engfailanal.2020.104986
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A failure analysis of welded pipes (ASTM A312 Grade TP 316L) in a water treatment plant was done and it is presented in this paper. The premature failure was detected by several water leakages caused by pitting corrosion three months after hydrostatic tests and before transferring the plant to the operator. The leakages were located near the bottom of the circumferential butt welds of the entire piping system. The samples were analyzed using visual inspection, radiographic examination, optical emission spectrometry, ferrite number (FN) measurements, metallographic examination and Scanning Electron Microscopy (SEM) coupled with Energy Dispersive Spectrometry (EDS). The results showed that the corrosion rate was extremely high compared to other studies available in the literature for austenitic stainless steel and the pits were in the weld metal and the Heat Affected Zone (HAZ) of the circumferential welds. The lack or deficiency of a purging gas during the field welding generated heat-tinted zones around the welds. Visual inspection showed that the pits were preferentially located at heat-tinted zones and they have large sub-surface cavities. The SEM inspection confirmed the presence of structures compatible with sulfate-reducing bacteria and iron-oxidizing bacteria and revealed that the failure was caused by microbiologically-influenced corrosion (MIC). The review of standards and codes used to perform hydrostatic testing of austenitic stainless steel piping systems showed that the water used for hydrostatic tests should have been treated before testing or the surfaces should have been deeply drained and dried. The failure was caused by the water used during the hydrostatic testing since it was not fully drained from the piping system and remained stagnant leading to MIC.
引用
收藏
页数:15
相关论文
共 44 条
[1]  
A. ASTM, 2017, A240A240M10 ASTM
[2]  
Afolabi A.S, 2008, J TECHNOL, V11, P171
[3]  
American A., 2006, A4274 AWS, V2006
[4]  
[Anonymous], 2002, FAIL ANAL PREV
[5]  
API, 1981, API 510 COD PRESS VE
[6]  
ASME, 2016, B3112016 ASME
[7]  
ASTM, 2019, A312A312M19 ASTM
[8]  
Brajkovic T, 2013, ENG REV, V33, P129
[9]  
da Silva P.S., 2019, MAT RES, V22
[10]  
Davis J.R., 2006, CORROSION WELDMENTS