Identification of glass and ceramics by X-ray fluorescence analysis with a pyroelectric X-ray generator

被引:18
|
作者
Ida, H [1 ]
Kawai, J
机构
[1] Kyoto Univ, Dept Mat Sci & Engn, Sakyo Ku, Kyoto 6068501, Japan
[2] Kyoto Pref Police HQ, Forens Sci Lab, Kyoto 6028550, Japan
关键词
D O I
10.2116/analsci.20.1211
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Applications of X-ray fluorescence (XRF) analysis with a pyroelectric X-ray generator are presented. Glass and ceramics were analyzed with this novel X-ray generator to examine its capability for analyzing nonmetallic inorganic material. Although the power of X-ray output was a few orders of magnitude lower than conventional X-ray tubes, many elements such as Si, K, Ca, Ti, Cr, Fe, Zn, Sr, Ba, and Pb were detected in glass and ceramic samples. Light elements such as Na, Mg, and Al were not detected because of the low fluorescence yield and the absorption of fluorescent X-rays in air. The elements detected or the relative peak intensities of the elements were different from each other, and the samples analyzed were identified by the XRF spectrum, notwithstanding the low power of the X-ray output. This novel device showed the sufficient capability for preliminary screening before strict identification of analytes. The pyroelectric X-ray generator can also be used to analyze large samples that cannot be put into ordinary XRF spectrometers because the device has no dimensional limitation of analytes.
引用
收藏
页码:1211 / 1215
页数:5
相关论文
共 50 条
  • [21] X-ray Peltier cooled detectors for X-ray fluorescence analysis
    Loupilov, A
    Sokolov, A
    Gostilo, V
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 463 - 464
  • [22] X-RAY FLUORESCENCE ANALYSIS
    ROBERT, A
    BULLETIN DE LA SOCIETE FRANCAISE DE CERAMIQUE, 1968, (78): : 33 - &
  • [23] Pyroelectric X-ray application to X-ray absorption and emission spectroscopies
    Kawai, Jun
    Ishii, Hideshi
    Ida, Hiroyuki
    X-RAY SPECTROMETRY, 2012, 41 (04) : 216 - 218
  • [24] The X-Ray Fluorescence Spectrometer Based on Pyroelectric Effect
    Dong Yi-fan
    Fan Rui-rui
    Guo Dong-ya
    Zhang Chun-lei
    Gao Min
    Wang Jin-zhou
    Liu Ya-qing
    Zhou Da-wei
    Wang Huan-yu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (02) : 550 - 554
  • [25] Trends in X-ray Fluorescence and X-ray Diffraction
    Paunesku, Tatjana
    SPECTROSCOPY, 2016, 31 (07) : 35 - +
  • [26] AN INVESTIGATION OF X-RAY-FLUORESCENCE ANALYSIS WITH AN X-RAY FOCUSING SYSTEM (X-RAY LENS)
    YAN, YM
    DING, XL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 82 (01): : 121 - 124
  • [27] PYROELECTRIC X-RAY-DETECTORS AND X-RAY PYROMETERS
    WANG, CL
    AUERBACH, JM
    ECKELS, JD
    KOO, JC
    KORNBLUM, HN
    PRICE, DF
    SMITH, JA
    STOTLAR, SC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (08): : 2177 - 2178
  • [28] Reduction of Spectral Interference between X-ray Peaks Originating from an X-ray Tube and X-ray Fluorescence Peaks in Total Reflection X-ray Fluorescence Analysis
    Kunimura, Shinsuke
    Sugawara, Yugo
    Kudo, Shumpei
    ISIJ INTERNATIONAL, 2017, 57 (05) : 953 - 955
  • [29] SPECTRAL DISTRIBUTION OF X-RAY TUBES FOR QUANTITATIVE X-RAY FLUORESCENCE ANALYSIS
    GILFRICH, JV
    BIRKS, LS
    ANALYTICAL CHEMISTRY, 1968, 40 (07) : 1077 - &
  • [30] X-RAY SPECTROGRAPHS FOR RAPID X-RAY FLUORESCENCE ANALYSIS WITH PHOTOGRAPHIC RECORDING
    PRIESTLEY, EF
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1958, 35 (11): : 409 - 413