Identification of glass and ceramics by X-ray fluorescence analysis with a pyroelectric X-ray generator

被引:18
|
作者
Ida, H [1 ]
Kawai, J
机构
[1] Kyoto Univ, Dept Mat Sci & Engn, Sakyo Ku, Kyoto 6068501, Japan
[2] Kyoto Pref Police HQ, Forens Sci Lab, Kyoto 6028550, Japan
关键词
D O I
10.2116/analsci.20.1211
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Applications of X-ray fluorescence (XRF) analysis with a pyroelectric X-ray generator are presented. Glass and ceramics were analyzed with this novel X-ray generator to examine its capability for analyzing nonmetallic inorganic material. Although the power of X-ray output was a few orders of magnitude lower than conventional X-ray tubes, many elements such as Si, K, Ca, Ti, Cr, Fe, Zn, Sr, Ba, and Pb were detected in glass and ceramic samples. Light elements such as Na, Mg, and Al were not detected because of the low fluorescence yield and the absorption of fluorescent X-rays in air. The elements detected or the relative peak intensities of the elements were different from each other, and the samples analyzed were identified by the XRF spectrum, notwithstanding the low power of the X-ray output. This novel device showed the sufficient capability for preliminary screening before strict identification of analytes. The pyroelectric X-ray generator can also be used to analyze large samples that cannot be put into ordinary XRF spectrometers because the device has no dimensional limitation of analytes.
引用
收藏
页码:1211 / 1215
页数:5
相关论文
共 50 条
  • [1] Identification of Glass and Ceramics by X-ray Fluorescence Analysis with a Pyroelectric X-ray Generator
    Hiroyuki Ida
    Jun Kawai
    Analytical Sciences, 2004, 20 : 1211 - 1215
  • [2] Identification of steel by X-ray fluorescence analysis with a pyroelectric X-ray generator
    Ida, H
    Kawai, J
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (04) : 735 - 738
  • [3] Identification of steel by X-ray fluorescence analysis with a pyroelectric X-ray generator
    Hiroyuki Ida
    Jun Kawai
    Analytical and Bioanalytical Chemistry, 2004, 379 : 735 - 738
  • [4] Identification of material by X-ray fluorescence analysis with a pyroelectric X-ray generator
    Ali, M.
    Bonnett, E.
    Karataev, P.
    Kubankin, A.
    Oleinik, O.
    Margaryan, V.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (07):
  • [5] X-ray fluorescence analysis with a pyroelectric x-ray generator
    Kawai, J
    Ida, H
    Murakami, H
    Koyama, T
    X-RAY SPECTROMETRY, 2005, 34 (06) : 521 - 524
  • [6] Portable x-ray fluorescence spectrometer with a pyroelectric x-ray generator
    Ida, H
    Kawai, J
    X-RAY SPECTROMETRY, 2005, 34 (03) : 225 - 229
  • [7] PYROELECTRIC X-RAY GENERATOR
    BROWNRIDGE, JD
    NATURE, 1992, 358 (6384) : 287 - 288
  • [8] Focusing of x-rays emitted by a pyroelectric x-ray generator for micro x-ray fluorescence
    Wilke, Markus
    Harnisch, Karsten
    Knapp, Wolfram
    Ecke, Martin
    Halle, Thorsten
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2019, 37 (01):
  • [9] Spatially resolved X-ray fluorescence analysis with a pyroelectric X-ray emitter
    Hatakeyama, So
    Kunimura, Shinsuke
    Sasaki, Nobuharu
    Yamamoto, Takashi
    Kawai, Jun
    ANALYTICAL SCIENCES, 2008, 24 (07) : 847 - 850
  • [10] Spatially Resolved X-ray Fluorescence Analysis with a Pyroelectric X-ray Emitter
    So Hatakeyama
    Shinsuke Kunimura
    Nobuharu Sasaki
    Takashi Yamamoto
    Jun Kawai
    Analytical Sciences, 2008, 24 : 847 - 850