Digital imaging to assist preoperative planning for ipsilateral rotational autokeratoplasty

被引:4
作者
Bower, Kraig S. [1 ]
Mines, Michael J. [1 ]
Stutzman, Richard D. [1 ]
机构
[1] Walter Reed Army Med Ctr, Ctr Refract Surg, Ophthalmol Serv, Washington, DC 20307 USA
关键词
D O I
10.1258/135763306778682369
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
A 14-month-old child with a central corneal scar underwent rotational autografting of his cornea to clear his visual axis. This was accomplished through eccentric trephination and 180 degree rotation of the central cornea. A preoperative image of the patient's cornea was manipulated digitally using a common commercial image-processing software package. This allowed accurate prediction of the best trephine size and location prior to surgery. Digital imaging played an important role in preoperative surgical planning and demonstrates the potential for tele-ophthalmology.
引用
收藏
页码:374 / 376
页数:3
相关论文
共 13 条
[1]  
BOURNE WM, 1978, OPHTHALMOLOGY, V85, P1312
[2]   The effect of fourth-generation fluoroquinolones gatifloxacin and moxifloxacin on epithelial healing following photorefractive keratectomy [J].
Burka, JM ;
Bower, KS ;
Vanroekel, RC ;
Stutzman, RD ;
Kuzmowych, CP ;
Howard, RS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (01) :83-87
[3]   CALCULATION OF SIZE AND LOCATION OF AUTOLOGOUS IPSILATERAL ROTATING KERATOPLASTY [J].
JONAS, JB ;
PANDAJONAS, S .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1994, 232 (09) :538-544
[4]   COMPUTERIZED METHOD FOR ROTATIONAL AUTOKERATOPLASTY [J].
KARPOUZAS, I ;
POULIQUEN, YJM .
CORNEA, 1991, 10 (05) :369-371
[5]   Ipsilateral rotational autokeratoplasty - An alternative to penetrating keratoplasty in nonprogressive central corneal scars [J].
Murthy, S ;
Bansal, AK ;
Sridhar, MS ;
Rao, GN .
CORNEA, 2001, 20 (05) :455-457
[6]   A standardized approach for iris color determination [J].
Niggemann, B ;
Weinbauer, G ;
Vogel, F ;
Korte, R .
INTERNATIONAL JOURNAL OF TOXICOLOGY, 2003, 22 (01) :49-51
[7]   A comparison of manual and automated methods of measuring conjunctival vessel widths from photographic and digital images [J].
Owen, CG ;
Ellis, TJ ;
Woodward, EG .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (02) :74-81
[8]   Image analysis to improve diagnosis of exfoliation [J].
Puska, P ;
Sassi, R ;
Tarkkanen, A .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (01) :58-60
[9]  
Tiffany JM, 1998, ADV EXP MED BIOL, V438, P433
[10]   Estimation of pupil size by digital photography [J].
Twa, MD ;
Bailey, MD ;
Hayes, J ;
Bullimore, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) :381-389