A Comparison of a Direct Electron Detector and a High-Speed Video Camera for a Scanning Precession Electron Diffraction Phase and Orientation Mapping

被引:18
|
作者
MacLaren, Ian [1 ]
Frutos-Myro, Enrique [2 ]
McGrouther, Damien [1 ]
McFadzean, Sam [1 ]
Weiss, Jon Karl [3 ]
Cosart, Doug [3 ]
Portillo, Joaquim [4 ,5 ]
Robins, Alan [4 ]
Nicolopoulos, Stavros [4 ]
Nebot del Busto, Eduardo [6 ]
Skogeby, Richard [6 ]
机构
[1] Univ Glasgow, Sch Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[2] Univ Glasgow, Sch Engn, Glasgow G12 8QQ, Lanark, Scotland
[3] NanoMEGAS USA, 1095 W Rio Salado Pkwy,Suite 110, Tempe, AZ 85281 USA
[4] NanoMEGAS SPRL, Bd Edmond Machtens 79 Bte 22, B-1080 Brussels, Belgium
[5] Univ Barcelona, Ctr Cient & Tecnol, Sole & Sabaris 1-3, Barcelona 08028, Spain
[6] Quantum Detectors Ltd, R104,RAL, Oxford OX11 0QX, England
基金
英国工程与自然科学研究理事会;
关键词
electron crystallography; electron microscopy; direct electron detectors; crystallographic orientation mapping; precession electron diffraction; STEM; GRAIN; TOMOGRAPHY; MICROSCOPE; EFFICIENCY; CRYSTALS; TEM;
D O I
10.1017/S1431927620024411
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A scanning precession electron diffraction system has been integrated with a direct electron detector to allow the collection of improved quality diffraction patterns. This has been used on a two-phase alpha-beta titanium alloy (Timetal (R) 575) for phase and orientation mapping using an existing pattern-matching algorithm and has been compared to the commonly used detector system, which consisted of a high-speed video-camera imaging the small phosphor focusing screen. Noise is appreciably lower with the direct electron detector, and this is especially noticeable further from the diffraction pattern center where the real electron scattering is reduced and both diffraction spots and inelastic scattering between spots are weaker. The results for orientation mapping are a significant improvement in phase and orientation indexing reliability, especially of fine nanoscale laths of alpha-Ti, where the weak diffracted signal is rather lost in the noise for the optically coupled camera. This was done at a dose of similar to 19 e(-)/angstrom(2), and there is clearly a prospect for reducing the current further while still producing indexable patterns. This opens the way for precession diffraction phase and orientation mapping of radiation-sensitive crystalline materials.
引用
收藏
页码:1110 / 1116
页数:7
相关论文
共 50 条
  • [31] Orientation and phase mapping in the transmission electron microscope using precession-assisted diffraction spot recognition: state-of-the-art results
    Viladot, D.
    Veron, M.
    Gemmi, M.
    Peiro, F.
    Portillo, J.
    Estrade, S.
    Mendoza, J.
    Llorca-Isern, N.
    Nicolopoulos, S.
    JOURNAL OF MICROSCOPY, 2013, 252 (01) : 23 - 34
  • [32] HIGH-SPEED DIRECT WRITE ELECTRON-BEAM SYSTEM
    URA, F
    RISSMAN, P
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 333 : 89 - 93
  • [33] NOVEL HIGH-SPEED TRANSISTOR USING ELECTRON-WAVE DIFFRACTION
    FURUYA, K
    JOURNAL OF APPLIED PHYSICS, 1987, 62 (04) : 1492 - 1494
  • [34] THERMAL SURFACE MODIFICATION BY ELECTRON-BEAM HIGH-SPEED SCANNING
    SCHILLER, S
    PANZER, S
    SURFACE & COATINGS TECHNOLOGY, 1989, 39 (1-3): : 521 - 529
  • [35] THERMAL SURFACE MODIFICATION BY ELECTRON-BEAM HIGH-SPEED SCANNING
    SCHILLER, S
    PANZER, S
    ANNUAL REVIEW OF MATERIALS SCIENCE, 1988, 18 : 121 - 140
  • [36] A SCANNING ELECTRON-MICROSCOPY STUDY OF CARBIDES IN HIGH-SPEED STEELS
    DING, PD
    SHI, GQ
    ZHOU, SZ
    MATERIALS CHARACTERIZATION, 1992, 29 (01) : 15 - 24
  • [37] High-speed Position Tracking for Nanohandling inside Scanning Electron Microscopes
    Jasper, Daniel
    ICRA: 2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-7, 2009, : 1952 - 1957
  • [38] Microstructural Characterization by Automated Crystal Orientation and Phase Mapping by Precession Electron Diffraction in TEM: Application to Hot Deformation of a γ-TiAl-based Alloy
    Singh, Vajinder
    Mondal, Chandan
    Bhattacharjee, P. P.
    Ghosal, P.
    MICROSCOPY AND MICROANALYSIS, 2019, 25 (06) : 1457 - 1465
  • [39] High precision orientation mapping from 4D-STEM precession electron diffraction data through quantitative analysis of diffracted intensities
    Correa, Leonardo M.
    Ortega, Eduardo
    Ponce, Arturo
    Cotta, Monica A.
    Ugarte, Daniel
    ULTRAMICROSCOPY, 2024, 259
  • [40] ELECTRON WAVE DIFFRACTION BY NANOMETER GRATING AND ITS APPLICATION FOR HIGH-SPEED TRANSISTORS
    FURUYA, K
    KURISHIMA, K
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1988, 6 (06): : 1845 - 1848