A Comparison of a Direct Electron Detector and a High-Speed Video Camera for a Scanning Precession Electron Diffraction Phase and Orientation Mapping

被引:18
|
作者
MacLaren, Ian [1 ]
Frutos-Myro, Enrique [2 ]
McGrouther, Damien [1 ]
McFadzean, Sam [1 ]
Weiss, Jon Karl [3 ]
Cosart, Doug [3 ]
Portillo, Joaquim [4 ,5 ]
Robins, Alan [4 ]
Nicolopoulos, Stavros [4 ]
Nebot del Busto, Eduardo [6 ]
Skogeby, Richard [6 ]
机构
[1] Univ Glasgow, Sch Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[2] Univ Glasgow, Sch Engn, Glasgow G12 8QQ, Lanark, Scotland
[3] NanoMEGAS USA, 1095 W Rio Salado Pkwy,Suite 110, Tempe, AZ 85281 USA
[4] NanoMEGAS SPRL, Bd Edmond Machtens 79 Bte 22, B-1080 Brussels, Belgium
[5] Univ Barcelona, Ctr Cient & Tecnol, Sole & Sabaris 1-3, Barcelona 08028, Spain
[6] Quantum Detectors Ltd, R104,RAL, Oxford OX11 0QX, England
基金
英国工程与自然科学研究理事会;
关键词
electron crystallography; electron microscopy; direct electron detectors; crystallographic orientation mapping; precession electron diffraction; STEM; GRAIN; TOMOGRAPHY; MICROSCOPE; EFFICIENCY; CRYSTALS; TEM;
D O I
10.1017/S1431927620024411
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A scanning precession electron diffraction system has been integrated with a direct electron detector to allow the collection of improved quality diffraction patterns. This has been used on a two-phase alpha-beta titanium alloy (Timetal (R) 575) for phase and orientation mapping using an existing pattern-matching algorithm and has been compared to the commonly used detector system, which consisted of a high-speed video-camera imaging the small phosphor focusing screen. Noise is appreciably lower with the direct electron detector, and this is especially noticeable further from the diffraction pattern center where the real electron scattering is reduced and both diffraction spots and inelastic scattering between spots are weaker. The results for orientation mapping are a significant improvement in phase and orientation indexing reliability, especially of fine nanoscale laths of alpha-Ti, where the weak diffracted signal is rather lost in the noise for the optically coupled camera. This was done at a dose of similar to 19 e(-)/angstrom(2), and there is clearly a prospect for reducing the current further while still producing indexable patterns. This opens the way for precession diffraction phase and orientation mapping of radiation-sensitive crystalline materials.
引用
收藏
页码:1110 / 1116
页数:7
相关论文
共 50 条
  • [1] Precession Electron Diffraction assisted Orientation Mapping in the Transmission Electron Microscope
    Portillo, Joaquim
    Rauch, Edgar F.
    Nicolopoulos, Stavros
    Gemmi, Mauro
    Bultreys, Daniel
    ADVANCED ELECTRON MICROSCOPY AND NANOMATERIALS, 2010, 644 : 1 - +
  • [2] Automated nanocrystal orientation and phase mapping in the transmission electron microscope on the basis of precession electron diffraction
    Rauch, Edgar F.
    Portillo, Joaquin
    Nicolopoulos, Stavros
    Bultreys, Daniel
    Rouvimov, Sergei
    Moeck, Peter
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE-CRYSTALLINE MATERIALS, 2010, 225 (2-3): : 103 - 109
  • [3] Nanocrystalline orientation and phase mapping of textured coatings revealed by precession electron diffraction
    Mohseni, H.
    Collins, P. C.
    Scharf, T. W.
    NANOMATERIALS AND ENERGY, 2012, 1 (06) : 318 - 323
  • [4] Is fast mapping good mapping? A review of the benefits of high-speed orientation mapping using electron backscatter diffraction
    Trimby, P
    Day, A
    Mehnert, K
    Schmidt, NH
    JOURNAL OF MICROSCOPY, 2002, 205 (03) : 259 - 269
  • [5] HIGH-SPEED DIRECT-RECORDING SYSTEM FOR ELECTRON DIFFRACTION
    GRIGSON, CW
    NATURE, 1961, 192 (480) : 647 - &
  • [6] Scanning precession electron diffraction data analysis approaches for phase mapping of precipitates in aluminium alloys
    Thronsen, E.
    Bergh, T.
    Thorsen, T. I.
    Christiansen, E. F.
    Frafjord, J.
    Crout, P.
    van Helvoort, A. T. J.
    Midgley, P. A.
    Holmestad, R.
    ULTRAMICROSCOPY, 2024, 255
  • [7] Scanning precession electron diffraction data analysis approaches for phase mapping of precipitates in aluminium alloys
    Thronsen, E.
    Bergh, T.
    Thorsen, T.I.
    Christiansen, E.F.
    Frafjord, J.
    Crout, P.
    van Helvoort, A.T.J.
    Midgley, P.A.
    Holmestad, R.
    Ultramicroscopy, 2024, 255
  • [8] Automated Crystal Orientation Mapping by Precession Electron Diffraction-Assisted Four-Dimensional Scanning Transmission Electron Microscopy Using a Scintillator-Based CMOS Detector
    Jeong, Jiwon
    Cautaerts, Niels
    Dehm, Gerhard
    Liebscher, Christian H.
    MICROSCOPY AND MICROANALYSIS, 2021, 27 (05) : 1102 - 1112
  • [9] Strain mapping at the nanoscale using precession electron diffraction in transmission electron microscope with off axis camera
    Vigouroux, M. P.
    Delaye, V.
    Bernier, N.
    Cipro, R.
    Lafond, D.
    Audoit, G.
    Baron, T.
    Rouviere, J. L.
    Martin, M.
    Chenevier, B.
    Bertin, F.
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [10] A high-speed area detector for novel imaging techniques in a scanning transmission electron microscope
    Caswell, T. A.
    Ercius, P.
    Tate, M. W.
    Ercan, A.
    Gruner, S. M.
    Muller, D. A.
    ULTRAMICROSCOPY, 2009, 109 (04) : 304 - 311